摘要
Objective:The primary rationale of the study is to assess the biomechanical aspects of Champy's, monoplanar, biplanar, and 3D strut plating systems using an in vitro model in the management of the angle of mandible fracture.Methods:Thirty-two hemi-sectioned mandibles (N = 32) were obtained from adult goats and divided into four groups (N = 8) for different plating techniques: monoplanar, biplanar, Champy's, and three-dimensional curved angle strut plating. A customized biomechanical test machine simulated masticatory loads by applying compressive forces. Force versus displacement data were recorded using an Instron Lloyd LRX machine.Results:Plating techniques with two plates exhibited higher resistance to displacement than single-plate techniques. The three-dimensional curved angle strut plate group had the highest mean compressive strength (184.7913 N), followed by biplanar plating (170.29 N), monoplanar plating (159.3419 N), and Champy's plating (55.48375 N). Statistical analysis showed significant differences between the three-dimensional curved angle strut plating technique and Champy's plating technique (P value <= 0.0016*), as well as between the biplanar plating technique and Champy's plating technique (P value <= 0.0010*).Conclusion:The three-dimensional curved angle strut plate and biplanar plating techniques exhibited superior biomechanical performance compared to monoplanar and Champy's plating techniques.
引用
收藏
页码:S4821 / S4825
页数:5
相关论文
共 16 条
[1]   Biomechanical comparison of different plating techniques in repair of mandibular angle fractures [J].
Alkan, Alper ;
Celebi, Nukhet ;
Ozden, Bora ;
Bas, Burcn ;
Inal, Samet .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2007, 104 (06) :752-756
[2]   ANISOTROPIC YIELD BEHAVIOR OF BONE UNDER COMBINED AXIAL FORCE AND TORQUE [J].
CEZAYIRLIOGLU, H ;
BAHNIUK, E ;
DAVY, DT ;
HEIPLE, KG .
JOURNAL OF BIOMECHANICS, 1985, 18 (01) :61-69
[3]  
Champy M., 1975, Die Behandlung der Mandibularfrakturen mittels Osteosynthese ohne intermaxillare Ruhigstellung nach der Technik von FX Michelet
[4]  
Changmai Arindom, 2021, Natural Volatiles & Essential Oils, V8, P12519
[5]   Evaluation of 2.0-mm Titanium Three-Dimensional Curved Angle Strut Plate in the Fixation of Mandibular Angle Fractures-A Prospective Clinical and Radiological Analysis [J].
Chhabaria, Gaurav ;
Halli, Rajshekhar ;
Chandan, Sanjay ;
Joshi, Samir ;
Setiya, Sneha ;
Shah, Anand .
CRANIOMAXILLOFACIAL TRAUMA & RECONSTRUCTION, 2014, 7 (02) :119-125
[6]   Plating techniques and plate orientation in repair of mandibular angle fractures: An in vitro study [J].
Fedok, FG ;
Van Kooten, DW ;
DeJoseph, LM ;
McGinn, JD ;
Sobota, B ;
Levin, RJ ;
Jacobs, CR .
LARYNGOSCOPE, 1998, 108 (08) :1218-1224
[7]   FUNCTIONAL MOVEMENTS OF MANDIBLE [J].
GIBBS, CH ;
MESSERMAN, T ;
RESWICK, JB ;
DERDA, HJ .
JOURNAL OF PROSTHETIC DENTISTRY, 1971, 26 (06) :604-+
[8]   Fixation of mandibular angle fractures with a 2.0-mm 3-dimensional curved angle strut plate [J].
Guimond, C ;
Johnson, JV ;
Marchena, JM .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2005, 63 (02) :209-214
[9]   INFECTION AFTER RIGID INTERNAL-FIXATION OF MANDIBULAR FRACTURES - A CLINICAL AND RADIOLOGIC STUDY [J].
IIZUKA, T ;
LINDQVIST, C ;
HALLIKAINEN, D ;
PAUKKU, P .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1991, 49 (06) :585-593
[10]  
Keaveny T.M., 1993, BONE, P285