INVESTIGATION OF THE EFFECTS OF GEOMETRY VARIATIONS ON THE PERFORMANCE OF AN ADJOINT OPTIMIZED FILM COOLING HOLE

被引:0
作者
Ellinger, Molly E. [1 ]
Flach, Elise M. [1 ]
Boger, David G. [1 ]
机构
[1] Univ Texas Austin, Walker Dept Mech Engn, Austin, TX 78712 USA
来源
PROCEEDINGS OF ASME TURBO EXPO 2024: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, GT2024, VOL 7 | 2024年
关键词
film cooling; adiabatic effectiveness; experimental; heat transfer; superposition; FAN-SHAPED HOLE; MULTIOBJECTIVE OPTIMIZATION; DENSITY;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In recent studies, a turbine film cooling shaped hole designed by adjoint optimization techniques (X-AOpt) was found to substantially increase film cooling performance with 90% greater adiabatic effectiveness than a reference 7-7-7 shaped hole. Two aspects of the geometry contribute to the high adiabatic effectiveness levels achieved by the X-AOpt holes: the shape of the internal geometry which improves the diffuser performance, and the external protrusions that generate counter-rotating vortices that push the core of the coolant jets towards the wall and spread the coolant laterally. In this study, insight into the relative importance of these two factors was obtained by testing the performance of a row of X-AOpt holes with the protrusions removed from the external surface. Experiments were also performed with varying pitch between X-AOpt holes to determine how the hole spacing affects film cooling effectiveness. Results from the tests of X-AOpt holes without external protrusions showed a 9% increase in adiabatic effectiveness compared to the baseline 15-15-1 holes, while the X-AOpt holes had a 45% higher adiabatic effectiveness than this standard. Experiments were also conducted using X-AOpt holes with varying pitch between holes of P/D = 4.0, 5.45, and 7.0. Results from these experiments showed that a decrease in pitch to P/D = 4.0 provided only a slightly increased adiabatic effectiveness compared to standard P/D = 5.45. However, increasing the pitch to P/D = 7.0 caused a 33% decrease in adiabatic effectiveness compared to the standard spacing. Superposition was found to significantly under predict adiabatic effectiveness for P/D = 4.0 and 7.0, indicating there is a dependence on lateral spacing for the X-AOpt geometry due to vortex interaction.
引用
收藏
页数:9
相关论文
共 22 条
  • [1] Scaling of performance for varying density ratio coolants on an airfoil with strong curvature and pressure gradient effects
    Ethridge, MI
    Cutbirth, JM
    Bogard, DG
    [J]. JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2001, 123 (02): : 231 - 237
  • [2] Studies on V-shaped flow control devices to improve film cooling effectiveness for air-cooled turbines
    Funazaki, Ken-ichi
    Yoshida, Nao
    Saito, Suzuna
    [J]. JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2023, 37 (05) : 2187 - 2197
  • [3] Funazaki Ken-ichi, 2017, P ASME TURB EXP 2017
  • [4] EFFECTS OF HOLE GEOMETRY AND DENSITY ON 3-DIMENSIONAL FILM COOLING
    GOLDSTEIN, RJ
    ECKERT, ERG
    BURGGRAF, F
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1974, 17 (05) : 595 - 607
  • [5] Discharge coefficient measurements of film-cooling holes with expanded exits
    Gritsch, M
    Schulz, A
    Wittig, S
    [J]. JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 1998, 120 (03): : 557 - 563
  • [6] Effect of internal coolant crossflow on the effectiveness of shaped film-cooling holes
    Gritsch, M
    Schulz, A
    Wittig, S
    [J]. JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2003, 125 (03): : 547 - 554
  • [7] Gutierrez Daniel, 2022, Journal of Turbomachinery, P1
  • [8] Han JeChin., Gas Turbine Heat Transfer and Cooling Technology
  • [9] Multi-objective optimization of laidback fan-shaped film cooling hole on Turbine Vane Suction Surface
    Huang, Ying
    Zhang, Jing-Zhou
    Wang, Chun-Hua
    Zhu, Xing-Dan
    [J]. HEAT AND MASS TRANSFER, 2019, 55 (04) : 1181 - 1194
  • [10] Jones Fraser B., 2021, P ASME TURB EXP 2021