Preservation of Liver Graft Using the Hypothermic Oxygenated Perfusion (HOPE) System: A single-center experience

被引:0
|
作者
Tamayo, Beatriz Villota [1 ,2 ,3 ]
Valero, Arkaitz Perfecto [2 ,3 ]
Ordorica, Patricia Ruiz [2 ,3 ]
Castineira, Alberto Ventoso [2 ,3 ]
Portela, Gerardo Moro [1 ,2 ,3 ]
Gutierrez, Jaime Encinas [1 ,2 ,3 ]
Etxeberria, Ibone Palomares [2 ,3 ]
Calvo, Mikel Prieto [2 ,3 ]
Herrero, Sara Mambrilla [2 ,3 ]
Vicente, Teresa Pascual [1 ,2 ]
Ibarreche, Eunate Muga [2 ,4 ]
Labiano, Maria Senosiain [2 ]
Mateo, Mikel Gastaca [2 ,3 ]
机构
[1] Cruces Univ Hosp, Gen Surg Dept, Bilbao, Spain
[2] BioBizkaia Res Hlth Inst, Baracaldo, Bizkaia, Spain
[3] Cruces Univ Hosp, Hepatobiliary Surg & Liver Transplantat Unit, Bilbao, Spain
[4] Cruces Univ Hosp, Hepatol & Liver Transplantat Unit, Bilbao, Spain
关键词
MACHINE PERFUSION; TRANSPLANTATION;
D O I
10.1016/j.transproceed.2024.12.006
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Introduction. The hypothermic oxygenated perfusion (HOPE) system has been developed to improve the quality of previously considered suboptimal liver grafts, reduce complications, and increase the number of available donors. The aim of this study is to evaluate the results since its implementation in the liver transplant (LT) program at our center. Materials and Methods. We conducted a retrospective descriptive analysis of all LTs with HOPE from August 2022 to November 2023 with a minimum follow-up of 3 months. The indication criteria included: donor >75 years, macrovesicular steatosis (>30%) confirmed by biopsy, donor >70 years with additional risk factors (macroscopic steatosis or grossly suboptimal liver), anticipated cold ischemia time >6 hours, and donation after circulatory death with suboptimal graft or laboratory results. Results. Of the 96 LTs performed during this period, HOPE was used in 12 cases (12.5%). Two patients (16.7%) experienced postreperfusion syndrome, and one (8.3%) early allograft dysfunction was noted. Four patients (33.3%) had major surgical complications (Clavien-Dindo >= III). The median peak of ALT during the first 48 hours was 438.5 U/L (range 128-2475). There were two biliary complications (16.7%), one venous complication (8.3%), and two arterial complications (16.7%). With a median follow-up of 7.8 months, both patient survival and graft survival were 100%. Conclusion. In our experience, the use of HOPE seems to reduce ischemic damage and shows good short- and medium-term results.
引用
收藏
页码:55 / 58
页数:4
相关论文
共 50 条
  • [21] Mitochondrial injury during normothermic regional perfusion (NRP) and hypothermic oxygenated perfusion (HOPE) in a rodent model of DCD liver transplantation
    Panconesi, Rebecca
    Carvalho, Mauricio Flores
    Eden, Janina
    Fazi, Marilena
    Ansari, Fariha
    Mancina, Leandro
    Navari, Nadia
    Da Silva, Richard Xavier Sousa
    Dondossola, Daniele
    Borrego, Lucia Bautista
    Pietzke, Matthias
    Peris, Adriano
    Meierhofer, David
    Muiesan, Paolo
    Galkin, Alexander
    Marra, Fabio
    Dutkowski, Philipp
    Schlegel, Andrea
    EBIOMEDICINE, 2023, 98
  • [22] Effect of Hypothermic Machine Perfusion on the Preservation of Kidneys Donated After Cardiac Death: A Single-Center, Randomized, Controlled Trial
    Wang, Wei
    Xie, Dawei
    Hu, Xiaopeng
    Yin, Hang
    Liu, Hang
    Zhang, Xiaodong
    ARTIFICIAL ORGANS, 2017, 41 (08) : 753 - 758
  • [23] Single-Center Experience Using Marginal Liver Grafts in Korea
    Park, P. -J.
    Yu, Y. -D.
    Yoon, Y. -I.
    Kim, S. -R.
    Kim, D. -S.
    TRANSPLANTATION PROCEEDINGS, 2018, 50 (04) : 1147 - 1152
  • [24] A novel hypothermic machine perfusion system using a LifePort Kidney Transporter for the preservation of rat liver
    Zeng, Cheng
    Hu, Xiaoyan
    Wang, Yanfeng
    Zeng, Xianpeng
    Xiong, Yan
    Li, Ling
    Ye, Qifa
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2018, 15 (02) : 1410 - 1416
  • [25] End-ischemic hypothermic oxygenated machine perfusion does not improve renal outcome following liver transplantation from aged donors: A single-center retrospective report
    Noren, Asa
    Molne, Johan
    Bennet, William
    Sorensen, Gustaf
    Herlenius, Gustaf
    Lindner, Per
    Oltean, Mihai
    ARTIFICIAL ORGANS, 2023, 47 (12) : 1854 - 1864
  • [26] A multicenter randomized-controlled trial of hypothermic oxygenated perfusion (HOPE) for human liver grafts before transplantation
    Schlegel, Andrea
    Mueller, Matteo
    Mueller, Xavier
    Eden, Janina
    Panconesi, Rebecca
    von Felten, Stefanie
    Steigmiller, Klaus
    Da Silva, Richard X. Sousa
    de Rougemont, Olivier
    Mabrut, Jean-Yves
    Lesurtel, Mickael
    Cerisuelo, Miriam Cortes
    Heaton, Nigel D.
    Allard, Marc Antoine
    Adam, Rene
    Monbaliu, Diethard
    Jochmans, Ina
    Haring, Martijn P. D.
    Porte, Robert J.
    Parente, Alessandro
    Muiesan, Paolo
    Kron, Philipp
    Attia, Magdy
    Kollmann, Dagmar
    Berlakovich, Gabriela
    Rogiers, Xavier
    Petterson, Karin
    Kranich, Anne L.
    Amberg, Stefanie
    Mullhaupt, Beat
    Clavien, Pierre-Alain
    Dutkowski, Philipp
    JOURNAL OF HEPATOLOGY, 2023, 78 (04) : 783 - 793
  • [27] A multicenter randomized-controlled trial of hypothermic oxygenated perfusion (HOPE) for human liver grafts before transplantation
    Czigany, Zoltan
    Michalski, Christoph W.
    JOURNAL OF HEPATOLOGY, 2023, 79 (03) : E114 - E116
  • [28] Preliminary Single-Center Canadian Experience of Human Normothermic Ex Vivo Liver Perfusion: Results of a Clinical Trial
    Bral, M.
    Gala-Lopez, B.
    Bigam, D.
    Kneteman, N.
    Malcolm, A.
    Livingstone, S.
    Andres, A.
    Emamaullee, J.
    Russell, L.
    Coussios, C.
    West, L. J.
    Friend, P. J.
    Shapiro, A. M. J.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2017, 17 (04) : 1071 - 1080
  • [29] Outcomes of DCD liver transplantation using organs treated by hypothermic oxygenated perfusion before implantation
    Schlegel, Andrea
    Muller, Xavier
    Kalisvaart, Marit
    Muellhaupt, Beat
    Perera, M. Thamara P. R.
    Isaac, John R.
    Clavien, Pierre-Alain
    Muiesan, Paolo
    Dutkowski, Philipp
    JOURNAL OF HEPATOLOGY, 2019, 70 (01) : 50 - 57
  • [30] Risk Factors in Liver Retransplantation: A Single-Center Experience
    Crivellin, C.
    De Martin, E.
    Germani, G.
    Gambato, M.
    Senzolo, M.
    Russo, F. P.
    Vitale, A.
    Zanus, G.
    Cillo, U.
    Burra, P.
    TRANSPLANTATION PROCEEDINGS, 2011, 43 (04) : 1110 - 1113