Retinal microvascular remodeling associates with adverse events in continuous-flow left ventricular assist device-supported patients

被引:1
|
作者
Jeyakumar, Sambavan [1 ]
Nguyen, Helen [2 ]
Robson, Desiree [3 ]
Olsen, Nick [1 ]
Schnegg, Bruno [3 ]
Macdonald, Peter [1 ,3 ,4 ]
Fraser, Clare L. [5 ]
Liew, Gerald [1 ,2 ]
Jiang, Jacky [1 ]
Hayward, Christopher [1 ,3 ,4 ]
Muthiah, Kavitha [1 ,3 ,4 ]
机构
[1] Univ New South Wales Sydney, Sydney, Australia
[2] Univ Sydney, Westmead Inst Med Res, Sydney, Australia
[3] St Vincents Hosp Sydney, Dept Cardiol, Heart Failure & Transplant Unit, Sydney, Australia
[4] Victor Chang Cardiac Res Inst, Sydney, Australia
[5] Univ Sydney, Save Sight Inst, Sydney, Australia
关键词
left ventricular assist device; continuous flow; microvasculature; retinal vessels; adverse events; VASCULAR CALIBER; HEART-FAILURE; PULSATILE; MICROCIRCULATION; SOCIETY; IMPLANTATION; READMISSIONS; STROKE;
D O I
10.1016/j.healun.2024.07.017
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Continuous-flow left ventricular assist device (cfLVAD) use is effective in supporting patients with end-stage heart failure (ESHF). Reduced flow pulsatility within the systemic circulation in cfLVAD-supported patients may lead to alterations within the microcirculation. Temporal changes in microvasculature in relation to adverse events in cfLVAD-supported patients have not been studied. We aimed to profile changes within retinal microvasculature and its association with adverse events. METHODS: Retinal photography was performed using Topcon TRC-NW8 nonmydriatic fundus camera in cfLVAD-supported patients and ESHF control patients. Specific retinal measurements were evaluated using a validated semiautomated program. Demographic and adverse event data were documented. RESULTS: Forty-eight patients were studied (n = 29 cfLVAD, n = 19 ESHF). There were significant trends in retinal arteriolar caliber (B = -0.53 mu m, 95% confidence interval [CI]: -0.96 to -0.10, p = 0.016) and retinal fractal dimension parameters (B = 0.014, 95% CI: 0.001-0.002, p = 0.016) in linear mixed model regressions. Among cfLVAD patients, there was a significant association between the incidence of gastrointestinal bleeding and stepwise increases in retinal arteriolar-venular caliber ratio (hazard ratio: 3.03, 95% CI: 2.06-4.45, p = 0.005), a measure of arteriolar narrowing. CONCLUSIONS: We have observed for the first time that alterations in retinal microvasculature in cfLVAD-supported patients may be associated with gastrointestinal bleeding. While understanding these temporal changes may predict future adverse events in cfLVAD-supported patients, further multicenter studies are required to confirm the associations observed. (c) 2024 International Society for Heart and Lung Transplantation. All rights are reserved, including those for text and data mining, AI training, and similar technologies.
引用
收藏
页码:1975 / 1984
页数:10
相关论文
共 50 条
  • [1] Device-related epistaxis risk: continuous-flow left ventricular assist device-supported patients
    Alper Koycu
    Omer Vural
    Melike Bahcecitapar
    Sabuhi Jafarov
    Gulfem Beyazpinar
    Deniz Sarp Beyazpinar
    European Archives of Oto-Rhino-Laryngology, 2020, 277 : 2767 - 2773
  • [2] Device-related epistaxis risk: continuous-flow left ventricular assist device-supported patients
    Koycu, Alper
    Vural, Omer
    Bahcecitapar, Melike
    Jafarov, Sabuhi
    Beyazpinar, Gulfem
    Beyazpinar, Deniz Sarp
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2020, 277 (10) : 2767 - 2773
  • [3] Arterial Compliance and Continuous-Flow Left Ventricular Assist Device Pump Function
    Adji, Audrey
    Shehab, Sajad
    Jain, Pankaj
    Robson, Desiree
    Jansz, Paul
    Hayward, Christopher S.
    ASAIO JOURNAL, 2022, 68 (07) : 925 - 931
  • [4] Hemodynamic Stress Echocardiography in Patients Supported With a Continuous-Flow Left Ventricular Assist Device
    Andersen, Mads
    Gustafsson, Finn
    Madsen, Per Lav
    Brassard, Patrice
    Jensen, Anette Schophuus
    Secher, Niels
    Hassager, Christian
    Nordsborg, Nikolai
    Moller, Jacob Eifer
    JACC-CARDIOVASCULAR IMAGING, 2010, 3 (08) : 854 - 859
  • [5] Impact of continuous-flow left ventricular assist device support on right ventricular function
    Morgan, Jeffrey A.
    Paone, Gaetano
    Nemeh, Hassan W.
    Murthy, Raghav
    Williams, Celeste T.
    Lanfear, David E.
    Tita, Cristina
    Brewer, Robert J.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2013, 32 (04) : 398 - 403
  • [6] Twelve Hours of Sustained Ventricular Fibrillation Supported by a Continuous-Flow Left Ventricular Assist Device
    Sims, Daniel B.
    Rosner, Gregg
    Uriel, Nir
    Gonzalez-Costello, Jose
    Ehlert, Frederick A.
    Jorde, Ulrich P.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2012, 35 (05): : e144 - e148
  • [7] Endothelial Function in Patients With Continuous-Flow Left Ventricular Assist Devices
    Poredos, Pavel
    Jezovnik, Mateja K.
    Radovancevic, Rajko
    Gregoric, Igor D.
    ANGIOLOGY, 2021, 72 (01) : 9 - 15
  • [8] Cerebrovascular Events After Continuous-Flow Left Ventricular Assist Devices
    Pouya Tahsili-Fahadan
    David R. Curfman
    Albert A. Davis
    Noushin Yahyavi-Firouz-Abadi
    Lucia Rivera-Lara
    Michael E. Nassif
    Shane J. LaRue
    Gregory A. Ewald
    Allyson R. Zazulia
    Neurocritical Care, 2018, 29 : 225 - 232
  • [9] Cerebrovascular Events After Continuous-Flow Left Ventricular Assist Devices
    Tahsili-Fahadan, Pouya
    Curfman, David R.
    Davis, Albert A.
    Yahyavi-Firouz-Abadi, Noushin
    Rivera-Lara, Lucia
    Nassif, Michael E.
    LaRue, Shane J.
    Ewald, Gregory A.
    Zazulia, Allyson R.
    NEUROCRITICAL CARE, 2018, 29 (02) : 225 - 232
  • [10] Continuous-Flow Left Ventricular Assist Device and the Right Ventricle
    Puhlman, Mark
    AACN ADVANCED CRITICAL CARE, 2012, 23 (01) : 86 - 90