A Physics-Integrated Deep Learning Approach for Patient-Specific Non-Newtonian Blood Viscosity Assessment using PPG

被引:0
作者
Lee, Hyeong Jun [1 ,4 ]
Kim, Young Woo [1 ,4 ]
Shin, Seung Yong [2 ,4 ]
Lee, San Lee [3 ]
Kim, Chae Hyeon [3 ]
Chung, Kyung Soo [3 ]
Lee, Joon Sang [1 ,4 ]
机构
[1] Yonsei Univ, Dept Mech Engn, Div Biomarkers Imaging & Hemodynam Studies BIOS, Seoul, South Korea
[2] Korea Univ, Dept Internal Med, Ansan Hosp, Ansan, South Korea
[3] Yonsei Univ, Severance Hosp, Dept Internal Med, Div Pulm & Crit Care Med,Coll Med, Seoul, South Korea
[4] Ctr Precis Med Platform Based Smart Hemo Dynam Ind, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
Blood viscosity; Photoplethysmography; Wearable healthcare; Deep learning; Physics-informed loss function; FLUID;
D O I
10.1016/j.cmpb.2025.108740
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background and Objective: The aim of this study is to extract a patient-specific viscosity equation from photoplethysmography (PPG) data. An aging society has increased the need for remote, non-invasive health monitoring systems. However, the circulatory system remains beyond the scope of wearable devices. The solution might be found in the possibility of measuring blood viscosity from wearable devices. Blood viscosity information can be used to monitor and diagnose various circulatory system diseases. Therefore, if blood viscosity can be calculated from wearable photoplethysmography, the versatility of a non-invasive health monitoring system can be broadened. Methods: A hybrid 1D CNN-LSTM architecture incorporating physics-informed constraints was developed to integrate rheological principles into data-driven PPG analysis. The shear-viscosity equation derived from the viscometer was used as ground-truth data. The signal obtained from the wearable devices was processed with noise filtering and wandering elimination to gain stable blood pressure waves. The neural network was trained using k-fold cross-validation and weight factor optimization, with the loss function incorporating rheological constraints from the Carreau-Yasuda model. Results: The final estimation model achieved an accuracy of 81.1 %. The accuracy in the physiological shear range (50-300 s(-1)) was 84.0 %, outperforming other low and high shear regions. Mean absolute errors of 0.67 cP in the physiological range align with clinical viscometry tolerances (< 1 cP), demonstrating diagnostic feasibility. Statistical analysis revealed strong linear relationships between predicted and ground truth values across all shear rates (correlation coefficients: 0.619-0.742, p < 0.0001), with mean absolute errors decreasing from 7.84 cP at low shear rates to 0.67 cP in the physiological range. The accuracy and contribution of each parameter to the Carreau-Yasuda model were also analyzed. The results show that the contribution of each parameter varies based on the shear range, providing insight into weight factor optimization. Conclusion: By non-invasively estimating blood viscosity from PPG, the diagnostic capabilities of wearable healthcare systems can be expanded to target various diseases related to the circulatory system. The demonstrated accuracy in physiologically relevant shear ranges supports the potential clinical application of this methodology.
引用
收藏
页数:14
相关论文
共 38 条
  • [1] Evidence for the Higgs Boson Decay to a Z Boson and a Photon at the LHC
    Aad, G.
    Abbott, B.
    Abeling, K.
    Abicht, N. J.
    Abidi, S. H.
    Aboulhorma, A.
    Abramowicz, H.
    Abreu, H.
    Abulaiti, Y.
    Acharya, B. S.
    Bourdarios, C. Adam
    Adamczyk, L.
    Adamek, L.
    Addepalli, S. V.
    Addison, M. J.
    Adelman, J.
    Adiguzel, A.
    Adye, T.
    Affolder, A. A.
    Afik, Y.
    Agaras, M. N.
    Agarwala, J.
    Aggarwal, A.
    Agheorghiesei, C.
    Ahmad, A.
    Ahmadov, F.
    Ahmed, W. S.
    Ahuja, S.
    Ai, X.
    Aielli, G.
    Aikot, A.
    Tamlihat, M. Ait
    Aitbenchikh, B.
    Aizenberg, I.
    Akbiyik, M.
    Akesson, T. P. A.
    Akimov, A. V.
    Akiyama, D.
    Akolkar, N. N.
    Al Khoury, K.
    Alberghi, G. L.
    Albert, J.
    Albicocco, P.
    Albouy, G. L.
    Alderweireldt, S.
    Aleksa, M.
    Aleksandrov, I. N.
    Alexa, C.
    Alexopoulos, T.
    Alfonsi, F.
    [J]. PHYSICAL REVIEW LETTERS, 2024, 132 (02)
  • [2] Akishin A.D., 2021, J. Phys. Conf. Ser., V2096
  • [3] Aksoy Y., 2021, Nigde Omer Halisdemir Universitesi Muhendislik Bilimleri Dergisi, V10, P791
  • [4] Photoplethysmography and its application in clinical physiological measurement
    Allen, John
    [J]. PHYSIOLOGICAL MEASUREMENT, 2007, 28 (03) : R1 - R39
  • [5] Analysis of the Casson and Carreau-Yasuda non-Newtonian blood models in steady and oscillatory flows using the lattice Boltzmann method
    Boyd, Joshua
    Buick, James M.
    Green, Simon
    [J]. PHYSICS OF FLUIDS, 2007, 19 (09)
  • [6] Blood Flow Modeling in Coronary Arteries: A Review
    Carvalho, Violeta
    Pinho, Diana
    Lima, Rui A.
    Teixeira, Jose Carlos
    Teixeira, Senhorinha
    [J]. FLUIDS, 2021, 6 (02)
  • [7] Invasive imaging - Fractional flow reserve: a review
    De Bruyne, B.
    Sarma, J.
    [J]. HEART, 2008, 94 (07) : 949 - 959
  • [8] Dhanalakshmi S., 2022, Leveraging AI Technologies for Preventing and Detecting Sudden Cardiac Arrest and Death, P218
  • [9] Dias FM, 2024, Arxiv, DOI arXiv:2404.16049
  • [10] Quantitative Assessment of Coronary Microvascular Function Dynamic Single-Photon Emission Computed Tomography, Positron Emission Tomography, Ultrasound, Computed Tomography, and Magnetic Resonance Imaging
    Feher, Attila
    Sinusas, Albert J.
    [J]. CIRCULATION-CARDIOVASCULAR IMAGING, 2017, 10 (08)