Superiority of 3D planimetry over pressure half-time method for the assessment of mitral valve area after percutaneous edge-to-edge mitral repair

被引:0
作者
Ledesma, Miriam Estrada [1 ]
Plaza, Diana Bastidas [1 ]
Osinalde, Eduardo Pozo [1 ]
Marcos-Alberca, Pedro [1 ]
Blanco, Carmen Olmos [1 ]
Casado, Patricia Mahia [1 ]
Luaces, Maria [1 ]
de Diego, Jose Juan Gomez [1 ]
Nombela-Franco, Luis [1 ]
Jimenez-Quevedo, Pilar [1 ]
Tirado, Gabriela [1 ]
Yurrita, Luis Collado [2 ]
Fernandez-Ortiz, Antonio [1 ]
Villacastin, Julian [1 ]
de Agustin, Jose Alberto [1 ]
机构
[1] Hosp Clin San Carlos, Inst Cardiovasc, Madrid, Spain
[2] Univ Complutense Madrid, Dept Med, Madrid, Spain
来源
REVISTA ESPANOLA DE CARDIOLOGIA | 2024年 / 77卷 / 11期
关键词
Percutaneous mitral valve repair; Mitral valve area; 3D planimetry; Pressure half-time; Mean gradient; EAE/ASE RECOMMENDATIONS; ECHOCARDIOGRAPHY; REGURGITATION; STENOSIS; SURGERY; FLOW;
D O I
10.1016/j.rec.2024.03.017
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction and objectives: There is limited evidence to identify the most accurate method for measuring the mitral valve area (MVA) after percutaneous edge-to-edge mitral repair. Our objective was to evaluate the optimal method in this context and its correlation with the mean transmitral gradient. Methods: A registry of patients undergoing percutaneous mitral repair was conducted, analyzing different methods of measuring MVA and their correlation with the mean gradient. Results: We analyzed data from 167 patients. The mean age was 76 f 10.3 years, 54% were men, and 46% were women. Etiology was degenerative in 45%, functional in 39%, and mixed in 16%. Postclip MVA measurements were 1.89 f 0.60 cm2 using pressure half-time (PHT), 2.87 f 0.83 cm2 using 3D planimetry, and the mean gradient was 3 f 1.19 mmHg. MVA using 3D planimetry showed a stronger correlation with the mean gradient (r = 0.46, P < .001) than MVA obtained by PHT (r = 0.19, P = .048). Interobserver agreement was also higher with 3D planimetry than with PHT (intraclass correlation coefficient of 0.90 vs 0.81 and variation coefficient of 9.6 vs 19.7%, respectively). Conclusions: Our study demonstrates that the PHT method significantly underestimates MVA after clip implantation compared with direct measurement using transesophageal 3D planimetry. The latter method also correlates better with postimplantation gradients and has less interobserver variability. These results suggest that 3D planimetry is a more appropriate method for assessing postclip mitral stenosis. (c) 2024 Sociedad Espanola de Cardiolog & imath;a. Published by Elsevier Espana, S.L.U. All rights are reserved, including those for text and data mining, AI training, and similar technologies.
引用
收藏
页码:919 / 925
页数:7
相关论文
共 28 条
[1]   In-hospital outcomes of transcatheter mitral valve repair with Mitraclip in patients with pulmonary hypertension: Insights from the National Inpatient Sample [J].
Ahmed, Abdelrahman ;
Akintoye, Emmanuel ;
Adegbala, Oluwole ;
Yassin, Ahmed ;
Subahi, Ahmed ;
Bangura, Lamin ;
Abubakar, Hossam ;
Elder, Mahir ;
Shokr, Mohamed ;
Afonso, Luis .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2019, 94 (01) :E30-E36
[2]   Analysis of Procedural Effects of Percutaneous Edge-to-Edge Mitral Valve Repair by 2D and 3D Echocardiography [J].
Altiok, Ertunc ;
Hamada, Sandra ;
Brehmer, Kathrin ;
Kuhr, Kathrin ;
Reith, Sebastian ;
Becker, Michael ;
Schroeder, Joerg ;
Almalla, Mohammad ;
Lehmacher, Walter ;
Marx, Nikolaus ;
Hoffmann, Rainer .
CIRCULATION-CARDIOVASCULAR IMAGING, 2012, 5 (06) :748-755
[3]   Echocardiographic assessment of valve stenosis: EAE/ASE recommendations for clinical practice [J].
Baumgartner, Helmut ;
Hung, Judy ;
Bermejo, Javier ;
Chambers, John B. ;
Evangelista, Arturo ;
Griffin, Brian P. ;
Iung, Bernard ;
Otto, Catherine M. ;
Pellikka, Patricia A. ;
Quinones, Miguel .
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2009, 10 (01) :1-25
[4]   Assessment of Mitral Valve Area During Percutaneous Mitral Valve Repair Using the MitraClip System Comparison of Different Echocardiographic Methods [J].
Biaggi, Patric ;
Felix, Christian ;
Gruner, Christiane ;
Herzog, Bernhard A. ;
Hohlfeld, Sabine ;
Gaemperli, Oliver ;
Staehli, Barbara E. ;
Paul, Michaela ;
Held, Leonhard ;
Tanner, Felix C. ;
Gruenenfelder, Juerg ;
Corti, Roberto ;
Bettex, Dominique .
CIRCULATION-CARDIOVASCULAR IMAGING, 2013, 6 (06) :1032-1040
[5]  
Bonow RO, 2020, J AM COLL CARDIOL, V75, P2236, DOI 10.1016/j.jacc.2020.02.005
[6]   Which method should be the reference method to evaluate the severity of rheumatic mitral stenosis? Gorlin's method versus 3D-echo [J].
de Isla, Leopoldo Perez ;
Casanova, Carlos ;
Almeria, Carlos ;
Rodrigo, Jose Luis ;
Cordeiro, Pedro ;
Mataix, Luis ;
Aubele, Ada Lia ;
Lang, Roberto ;
Zamorano, Jose Luis .
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2007, 8 (06) :470-473
[7]   3D vena contracta area after MitraClip© procedure: precise quantification of residual mitral regurgitation and identification of prognostic information [J].
Dietl, Alexander ;
Prieschenk, Christine ;
Eckert, Franziska ;
Birner, Christoph ;
Luchner, Andreas ;
Maier, Lars S. ;
Buchner, Stefan .
CARDIOVASCULAR ULTRASOUND, 2018, 16
[8]   Randomized Comparison of Percutaneous Repair and Surgery for Mitral Regurgitation 5-Year Results of EVEREST II [J].
Feldman, Ted ;
Kar, Saibal ;
Elmariah, Sammy ;
Smart, Steven C. ;
Trento, Alfredo ;
Siegel, Robert J. ;
Apruzzese, Patricia ;
Fail, Peter ;
Rinaldi, Michael J. ;
Smalling, Richard W. ;
Hermiller, James B. ;
Heimansohn, David ;
Gray, William A. ;
Grayburn, Paul A. ;
Mack, Michael J. ;
Lim, D. Scott ;
Ailawadi, Gorav ;
Herrmann, Howard C. ;
Acker, Michael A. ;
Silvestry, Frank E. ;
Foster, Elyse ;
Wang, Andrew ;
Glower, Donald D. ;
Mauri, Laura .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (25) :2844-2854
[9]   INFLUENCE OF ORIFICE GEOMETRY AND FLOW-RATE ON EFFECTIVE VALVE AREA - AN INVITRO STUDY [J].
FLACHSKAMPF, FA ;
WEYMAN, AE ;
GUERRERO, JL ;
THOMAS, JD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (05) :1173-1180
[10]   State-of-the-art intra-procedural imaging for the mitral and tricuspid PASCAL Repair System [J].
Hahn, Rebecca T. ;
Kodali, Susheel K. .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2022, 23 (03) :E94-E110