Protective biomechanical and histological changes in the false lumen wall in chronic type B aortic dissection

被引:0
作者
Dong, Hai [1 ,2 ]
Liu, Minliang [3 ,4 ]
Cebull, Hannah L. [5 ]
Chhabra, Arshiya [2 ]
Zhou, Yumeng [2 ]
Piccinelli, Marina [5 ]
Oshinski, John N. [5 ]
Elefteriades, John A. [3 ,4 ,6 ]
Gleason, Rudolph L. [2 ]
Leshnower, Bradley G. [1 ]
机构
[1] Emory Univ, Sch Med, Div Cardiothorac Surg, Carlyle Fraser Cardiothorac Res Lab, 1365 Clifton Rd,Suite A 2213, Atlanta, GA 30322 USA
[2] Emory Univ, Sch Med, Dept Radiol & Imaging Sci, Atlanta, GA 30322 USA
[3] Georgia Inst Technol, George W Woodruff Sch Mech Engn, Atlanta, GA USA
[4] Georgia Inst Technol, Wallace H Coulter Dept Biomed Engn, Atlanta, GA USA
[5] Texas Tech Univ, Dept Mech Engn, Lubbock, TX USA
[6] Yale Univ, Yale New Haven Hosp, Aort Inst, Div Cardiac Surg,Sch Med, New Haven, CT USA
来源
JTCVS OPEN | 2025年 / 23卷
基金
美国国家卫生研究院;
关键词
aortic dissection; false lumen wall; biomechanical stiffness; histological analysis; COLLAGEN-FIBERS; THORACIC AORTA; ANEURYSM;
D O I
10.1016/j.xjon.2024.11.012
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The outer false lumen wall (FLW) changes from thin/compliant to thick/ rigid as aortic dissection transitions from the acute to chronic phase. This study investigates biomechanical stiffness and histological changes of the FLW as the dissected aorta ages. Methods: The free outer FLW from human tissue was analyzed from chronic type B dissection (chronic-FLW) n = 10, acute type A dissection (acute-FLW) n = 10, and transplant donor descending aorta that was manually peeled into 2 layers (controlFLW) n = 17. Biaxial tension testing in the longitudinal and circumferential directions was performed and stress-strain curves were obtained. A lower and higher tangent modulus was determined to assess stiffness. Quantification of collagen and elastin was performed by calculating the fibers' volume fraction from Z-stack scans. Results: The higher tangent modulus of chronic-FLW is larger (P < .01) than the acute-FLW and control-FLW in longitudinal (5.09 +/- 0.9 MPa vs 1.72 +/- 0.56 MPa and 1.17 +/- 0.22 MPa) and circumferential (4.16 +/- 0.67 MPa vs 1.04 +/- 0.24 MPa and 1.07 +/- 0.16 MPa) directions. The lower tangent modulus of chronic-FLW is larger (P <.05) than acute-FLW and control-FLW in both directions (longitudinal: 0.72 +/- 0.24 MPa vs 0.13 +/- 0.02 MPa and 0.27 +/- 0.03 MPa circumferential:0.44 +/- 0.13 MPa vs 0.12 +/- 0.01 MPa and 0.21 +/- 0.02 MPa). The volume fraction of collagen was increased (P <.01) and the volume fraction of elastin was decreased (P <.001) when comparing chronic-FLW, acute-FLW, and controlFLW (collagen-volume fraction: 0.24 +/- 0.03 vs 0.12 +/- 0.03 and 0.08 +/- 0.02; elastinvolume fraction: 0.09 +/- 0.03 vs 0.28 +/- 0.03 and 0.39 +/- 0.04). Conclusions: As the acutely dissected aorta transitions to the chronic phase, the FL remodels by increasing collagen, decreasing elastin, and increasing aortic stiffness and thickness. This change in the chronic-FLW may be a protective adaptation to prevent FL enlargement and rupture in type B aortic dissection.
引用
收藏
页码:60 / 68
页数:9
相关论文
共 50 条
  • [31] Percutaneous gluteal artery access to embolize false lumen of type B aortic dissection in marfan patient
    Dajci, Ada
    Mohseni, Alireza
    Di Girolamo, Alessia
    Nardis, Pier Giorgio
    Mansour, Wassim
    JOURNAL OF VASCULAR SURGERY CASES INNOVATIONS AND TECHNIQUES, 2024, 10 (05):
  • [32] False lumen hemodynamics and partial thrombosis in chronic aortic dissection of the descending aorta
    Ruiz-Munoz, Aroa
    Guala, Andrea
    Dux-Santoy, Lydia
    Teixido-Tura, Gisela
    Valente, Filipa
    Garrido-Oliver, Juan
    Galian-Gay, Laura
    Gutierrez, Laura
    Fernandez-Galera, Ruben
    Casas-Masnou, Guillem
    Gonzalez-Alujas, Teresa
    Cuellar-Calabria, Hug
    Carrasco-Poves, Alejandro
    Morales-Galan, Alberto
    Johnson, Kevin M.
    Wieben, Oliver
    Ferreira-Gonzalez, Ignacio
    Evangelista, Arturo
    Rodriguez-Palomares, Jose
    EUROPEAN RADIOLOGY, 2024, 34 (8) : 5190 - 5200
  • [33] Hypertension-Induced Biomechanical Modifications in the Aortic Wall and Their Role in Stanford Type B Aortic Dissection
    Wei, Yuhao
    Li, Da
    Weng, Chengxin
    Wang, Jiarong
    Yuan, Ding
    Zheng, Tinghui
    BIOMEDICINES, 2024, 12 (10)
  • [34] Open and endovascular reinterventions after Candy Plug false lumen embolization of type B aortic dissection
    Loschi, Diletta
    Santoro, Annarita
    Rinaldi, Enrico
    Anselmi, Claudia
    Grignani, Camilla
    Chiesa, Roberto
    Melissano, Germano
    JOURNAL OF VASCULAR SURGERY, 2023, 78 (06) : 1409 - 1417
  • [35] Aortic Remodeling After False Lumen Embolization in Aortic Dissection
    Halloum, Nancy
    Meyer, Anna-Sophie
    Wenkel, Martin
    Dohle, Daniel-Sebastian
    Youssef, Marwan
    Dorweiler, Bernhard
    Treede, Hendrik
    El Beyrouti, Hazem
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (03)
  • [36] Effect of false lumen partial thrombosis on repaired acute type A aortic dissection
    Tsai, Meng-Ta
    Wu, Hsuan-Yin
    Roan, Jun-Neng
    Tsai, Yi-Shan
    Hsieh, Patrick C. H.
    Yang, Yu-Jen
    Luo, Chwan-Yau
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 148 (05) : 2140 - +
  • [37] A patient-specific study of type-B aortic dissection: evaluation of true-false lumen blood exchange
    Chen, Duanduan
    Mueller-Eschner, Matthias
    von Tengg-Kobligk, Hendrik
    Barber, David
    Boeckler, Dittmar
    Hose, Rod
    Ventikos, Yiannis
    BIOMEDICAL ENGINEERING ONLINE, 2013, 12
  • [38] Coil embolization for persistent false lumen in type B aortic dissection: A single-center retrospective study
    Li, Zilin
    Zhang, Jinglong
    Yu, Liming
    Zuo, Jian
    ASIAN JOURNAL OF SURGERY, 2024, 47 (12) : 5462 - 5463
  • [39] Successful endoluminal rescue of an endovascular graft unintentionally deployed in the false lumen of Stanford type B aortic dissection
    Ma, Xiang
    Fu, Weiguo
    Ma, Yi-Tong
    Karmacharya, Ujit
    Zhao, Jun
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2016, 151 (03) : E41 - E45
  • [40] Effects of the patent false lumen on the long-term outcome Iq of type B acute aortic dissection
    Akutsu, K
    Nejima, J
    Kiuchi, K
    Sasaki, K
    Ochi, M
    Tanaka, K
    Takano, T
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2004, 26 (02) : 359 - 366