Textile Organic Electrochemical Transistor for Non-Invasive Glucose Sensing

被引:0
|
作者
Brendgen, Rike [1 ]
Grethe, Thomas [2 ]
Schwarz-Pfeiffer, Anne [2 ]
机构
[1] Niederrhein Univ Appl Sci, Res Inst Text & Clothing FTB, Webschulstr 31, D-41065 Monchengladbach, Germany
[2] Niederrhein Univ Appl Sci, Fac Text & Clothing Technol, Webschulstr 31, D-41065 Monchengladbach, Germany
来源
MICRO-SWITZERLAND | 2024年 / 4卷 / 04期
关键词
organic electrochemical transistor; smart textiles; E-textiles; glucose sensing; non-invasive; biosensing; BLOOD-GLUCOSE; BIOSENSORS; OXIDASE; SENSORS;
D O I
10.3390/micro4040033
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The global rise in diabetes has highlighted the urgent need for continuous, non-invasive health monitoring solutions. Traditional glucose monitoring methods, which are invasive and often inconvenient, have created a demand for alternative technologies that can offer comfort, accuracy, and real-time data. In this study, the development of a textile-based organic electrochemical transistor (OECT) is presented, designed for non-invasive glucose sensing, aiming to integrate this technology seamlessly into everyday clothing. The document details the design, optimization, and testing of a one-component textile-based OECT, featuring a porous PEDOT:PSS structure and a glucose oxidase-modified electrolyte for effective glucose detection in sweat. The research demonstrates the feasibility of using this textile-based OECT for non-invasive glucose monitoring, with enhanced sensitivity and specificity achieved through the integration of glucose oxidase within the electrolyte and the innovative porous PEDOT:PSS design. These findings suggest a significant advancement in wearable health monitoring technologies, providing a promising pathway for the development of smart textiles capable of non-invasively tracking glucose levels. Future work should focus on refining this technology for clinical use, including individual calibration for accurate blood glucose correlation and its integration into commercially available smart textiles.
引用
收藏
页码:530 / 551
页数:22
相关论文
共 50 条
  • [21] Measuring and detecting blood glucose by methods non-invasive
    Ionescu, Marius
    PROCEEDINGS OF THE 2018 10TH INTERNATIONAL CONFERENCE ON ELECTRONICS, COMPUTERS AND ARTIFICIAL INTELLIGENCE (ECAI), 2018,
  • [22] An Ultrasonic Transceiver for Non-Invasive Intracranial Pressure Sensing
    Topalli, Gerald
    Fan, Yingying
    Cheung, Matt Y.
    Veeraraghavan, Ashok
    Hirzallah, Mohammad
    Chi, Taiyun
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2024, 18 (06) : 1220 - 1232
  • [23] The organic electrochemical transistor for biological applications
    Strakosas, Xenofon
    Bongo, Manuelle
    Owens, Roisin M.
    JOURNAL OF APPLIED POLYMER SCIENCE, 2015, 132 (15)
  • [24] Evaluation of the Sensitivity of Transmission Measurements at Millimeter Waves using Patch Antennas for Non-invasive Glucose Sensing
    Saha, Shimul
    Sotiriou, Ioannis
    Gouzouasis, Ioannis
    Cano-Garcia, Helena
    Palikaras, George
    Kosmas, Panagiotis
    Kallos, Efthymios
    2016 10TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION (EUCAP), 2016,
  • [25] On The Accuracy of Complex Permittivity Model of Glucose/Water Solutions for Non-invasive Microwave Blood Glucose Sensing
    Turgul, Volkan
    Kale, Izzet
    2015 E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2015,
  • [26] The discussion about the complexity of samples and the prediction accuracy of glucose concentration in non-invasive blood glucose sensing
    Gu, XY
    Liu, R
    Chen, WL
    Xu, KX
    Complex Dynamics and Fluctuations in Biomedical Photonics II, 2005, 5696 : 222 - 231
  • [27] Highly sensitive Non-enzymatic, Non-Invasive Disposable Electrochemical Polyaniline Nanocaps based Sweat Sensor for Glucose Monitoring
    Saraswathi, K. A.
    Reddy, M. Sai Bhargava
    Jayarambabu, N.
    Aich, Shampa
    Rao, Tumu Venkatappa
    MATERIALS LETTERS, 2023, 349
  • [28] A preliminary verification of the floating reference measurement method for non-invasive blood glucose sensing
    Min, Xiaolin
    Liu, Rong
    Fu, Bo
    Xu, Kexin
    OPTICS AND LASER TECHNOLOGY, 2017, 91 : 7 - 12
  • [29] A Novel Pressure Sensing Circuit for Non-invasive RF/Microwave Blood Glucose Sensors
    Turgul, Volkan
    Kale, Izzet
    2016 16TH MEDITERRANEAN MICROWAVE SYMPOSIUM (MMS), 2016,
  • [30] Research on the background correction in the non-invasive sensing of glucose by near-infrared spectroscopy
    Liu Rong
    Gu Xiao-yu
    Xu Ke-xin
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28 (08) : 1772 - 1775