Robust Optimum Design for Hybrid Vibration Control of Structures under Multihazard Scenarios of Earthquakes and Winds

被引:0
|
作者
Banerjee, Sarranya [1 ]
Saito, Taiki [1 ]
Matsagar, Vasant [2 ]
机构
[1] Toyohashi Univ Technol, Dept Architecture & Civil Engn, 1-1 Hibarigaoka,Tenpaku cho, Toyohashi, Aichi 4418580, Japan
[2] Indian Inst Technol Delhi, Dept Civil Engn, New Delhi 110016, India
来源
ASCE-ASME JOURNAL OF RISK AND UNCERTAINTY IN ENGINEERING SYSTEMS PART A-CIVIL ENGINEERING | 2025年 / 11卷 / 01期
关键词
Earthquake; Optimum design; Robust; Tuned mass damper; Unbonded fiber-reinforced elastomeric isolator; Wind; BASE-ISOLATED BUILDINGS; TUNED-MASS DAMPERS; OPTIMIZATION; METHODOLOGY; STIFFNESS; SYSTEM;
D O I
10.1061/AJRUA6.RUENG-1489
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Vibration control of structures under multiple hazards poses severe problems due to the inherent variability in the features of the different hazards. A robust optimum design of a hybrid vibration controller (HVC) comprising unbonded fiber-reinforced elastomeric isolators (UFREIs) and tuned mass dampers (TMDs) is proposed for the vibration control of structures under multihazard scenarios involving earthquakes and winds. Essentially, the role of the UFREI-based isolation system is to restrict the structural acceleration responses against earthquake excitations, and the aims of the TMDs are to reduce the earthquake-induced base displacements and wind-induced acceleration responses of the UFREI-isolated structure. Two TMDs are utilized, one at the base floor to control the excessive base displacements and the other at the top floor to diminish the structural acceleration responses. A novel risk-informed objective is formulated to attain the optimum design of the HVCs, considering the return periods of the various hazards. Subsequently, Bayesian optimization is used to obtain the optimum HVC parameters deterministically and also probabilistically, considering the uncertainties in the structural parameters. The robustness and performance of the optimally designed HVCs are examined under an ensemble of earthquake and wind excitations. Further, the efficacy of the proposed robust optimum HVC is demonstrated on a real-life hospital building. Results conclude that the probabilistic optimum HVC could effectively control the structural acceleration responses under the considered multihazard scenario, at the same time ensure that the base displacement of the HVC-controlled structure never exceeds the base displacement of the UFREI-isolated structure, under various uncertain scenarios.
引用
收藏
页数:21
相关论文
共 50 条
  • [21] Optimum design of the control devices for adjacent structures under earthquake excitation
    Teng, J
    Liu, HJ
    2005 IEEE INTERNATIONAL SYMPOSIUM ON INTELLIGENT CONTROL & 13TH MEDITERRANEAN CONFERENCE ON CONTROL AND AUTOMATION, VOLS 1 AND 2, 2005, : 328 - 333
  • [22] OPTIMUM STRUCTURAL DESIGN CONSIDERING VIBRATION CONTROL
    TADA, Y
    MATSUMOTO, R
    NAGAI, M
    JSME INTERNATIONAL JOURNAL SERIES III-VIBRATION CONTROL ENGINEERING ENGINEERING FOR INDUSTRY, 1992, 35 (03): : 413 - 420
  • [23] A structural control method of the vibration of flexible buildings in response to large earthquakes and strong winds
    Seto, K
    PROCEEDINGS OF THE 35TH IEEE CONFERENCE ON DECISION AND CONTROL, VOLS 1-4, 1996, : 658 - 663
  • [24] Robust vibration control of structures - Simulations and experiments
    Ma, K
    Melcher, J
    42ND IEEE CONFERENCE ON DECISION AND CONTROL, VOLS 1-6, PROCEEDINGS, 2003, : 6386 - 6391
  • [25] Active robust vibration control of flexible structures
    Hu, YR
    Ng, A
    JOURNAL OF SOUND AND VIBRATION, 2005, 288 (1-2) : 43 - 56
  • [26] Robust Vibration Control in Smart Composite Structures
    Faria, Albert Willian
    Ap Cavalini, Aldemir, Jr.
    Koroishi, Edson Hideki
    Steffen, Valder, Jr.
    Rade, Domingos Alves
    PROCEEDINGS OF THE 8TH INTERNATIONAL CONFERENCE ON STRUCTURAL DYNAMICS, EURODYN 2011, 2011, : 2690 - 2696
  • [27] Robust topology optimization for concurrent design of dynamic structures under hybrid uncertainties
    Zheng, Jing
    Luo, Zhen
    Jiang, Chao
    Gao, Jie
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2019, 120 : 540 - 559
  • [28] A study on the design parameters of the compliant LCD for structural vibration control under near fault earthquakes
    Ghosh, Aparna (aparna@civil.iiests.ac.in), 2016, Structural Engineering Research Centre (43):
  • [29] Robust Optimum Design of Multiple Tuned Mass Dampers for Vibration Control in Buildings Subjected to Seismic Excitation
    Vellar, Luciara Silva
    Ontiveros-Perez, Sergio Pastor
    Fadel Miguel, Leticia Fleck
    Fadel Miguel, Leandro Fleck
    SHOCK AND VIBRATION, 2019, 2019
  • [30] Structure and controller design for vibration control of flexible structures via robust pole assignment
    Okubo, H
    Ichikawa, H
    Nishimura, T
    PROCEEDINGS OF THE 1998 IEEE INTERNATIONAL CONFERENCE ON CONTROL APPLICATIONS, VOLS 1 AND 2, 1996, : 619 - 623