Comparative evaluation of marginal fit accuracy of two different designs of endocrown manufactured through CAD-CAM system: An in vitro study

被引:1
作者
Gupta, Khushbu Rakesh [1 ]
Gupta, Deepesh Kumar [1 ]
Jha, Anumeha [1 ]
Shukla, Shivam B. [1 ]
Dubey, Aayush Mukund [2 ]
机构
[1] Govt Dent Coll & Hosp, Dept Oral & Maxillofacial Prosthodont & Implantol, Raipur, Chhattisgarh, India
[2] Univ Cincinnati, Coll Med, Dept Epidemiol, Cincinnati, OH USA
关键词
Endocrown; marginal fit; ferrule; CAD-CAM; intraoral scanner;
D O I
10.4103/jips.jips_207_24
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aims:To compare the accuracy of marginal fit of CAD-CAM endocrown with two different preparation forms, i.e., endocrown with ferrule and endocrown without ferrule.Settings and Design:Various studies have opined on the impact of preparation form on the marginal fit of endocrown, but studies on the effect on the marginal fit of digitally milled endocrown with and without ferrule are sparse.Materials and Methods:Total of 30 typodont were sectioned 3 mm above the cemento-enamel junction, and central cavity was prepared to depict a severely destructed tooth. The typodonts were divided into two groups: Group 1 contained specimens for endocrown without ferrule (WoF); Group 2 contained specimens for endocrown with ferrule (WF). The typodonts were prepared based on standard preparation. The specimens were then scanned using intraoral scanner, and the stereolithography (STL) was generated. Endocrowns were designed in the Exocad software using a digital library. The STL file format is translated into millable data file format (CNC- Computer numerical control) in the inLAB MC X5 Milling machine. The marginal fit of endocrowns was then assessed in the stereomicroscope.Statistical Analysis:The data was analysed with a digital image analyser. The result was generated using a two-way ANOVA test. The significance level was set at P <= 0.05.Results:In the present study, the marginal fit of WoF showed a superior marginal fit than WF. A statistically significant difference was seen in the marginal fit of two endocrowns, with a higher marginal discrepancy observed in the endocrown with the ferrule. The P value for the difference in the means of the marginal gap without and with ferrule (-13.42) is zero. Maximum marginal gap of 96 micron is observed for with ferrule (WF) design at location B. Minimum marginal gap of 29 micron is observed for without ferrule (WoF) at location D.Conclusions:Endocrown without a ferrule can provide a better marginal fit and can contribute to the long-term survival of restoration.
引用
收藏
页码:74 / 79
页数:6
相关论文
共 50 条
[31]   Impact of different CAD software programs on marginal and internal fit of provisional crowns: An in vitro study [J].
Kizilkaya, Ayse Rencber ;
Kara, Aybuke .
HELIYON, 2024, 10 (02)
[32]   Marginal fit of 3-unit CAD-CAM zirconia frameworks fabricated using cone beam computed tomography scans: an experimental study [J].
Belgin, Huseyin Berkay ;
Kale, Ediz ;
Ozcelik, Tuncer Burak ;
Yilmaz, Burak .
ODONTOLOGY, 2022, 110 (02) :339-348
[33]   Evaluation of the Marginal Fit of Computer-Aided Design (CAD) and Computer-Aided Manufacturing (CAM) Zirconia Bridges Fabricated With Different Firing Cycles of Veneering Porcelain: An In Vitro Study [J].
Chokr, Hawraa ;
Alshaarani, Fendi ;
Husein, Hassan A. .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (02)
[34]   Fracture Resistance Evaluation and Failure Modes Rating Agreement for Two Endocrown Designs: An In Vitro Study [J].
Alzahrani, Saeed J. ;
Hajjaj, Maher S. ;
Yeslam, Hanin E. ;
Marghalani, Thamer Y. .
APPLIED SCIENCES-BASEL, 2023, 13 (05)
[35]   Comparative evaluation of the effects of laser and chemical denture disinfectants on the surface characteristics of CAD-CAM and conventional denture resins: An in vitro experimental study [J].
Moussa, Rania ;
Ellakany, Passent ;
Fouda, Shaimaa M. ;
El-Din, Mai Salah .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024,
[36]   Evaluation of the marginal and internal fit of CAD/CAM crowns designed using three different dental CAD programs: a 3-dimensional digital analysis study [J].
Farah, Ra'fat, I ;
Alresheedi, Bandar .
CLINICAL ORAL INVESTIGATIONS, 2023, 27 (01) :263-271
[37]   Evaluation of the Effect of Different Construction Techniques of CAD-CAM Milled, 3D-Printed, and Polyamide Denture Base Resins on Flexural Strength: An In Vitro Comparative Study [J].
Zeidan, Ahmed Abd El-Latif ;
Sherif, Ahmed Fadlallah ;
Baraka, Yasser ;
Abualsaud, Reem ;
Abdelrahim, Ramy Abdallah ;
Gad, Mohammed M. ;
Helal, Mohamed A. .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (01) :77-82
[38]   Evaluation of the marginal adaptation and debonding strength of two types of CAD-CAM implant-supported cement-retained crowns [J].
Ramzy, Nada Ahmed ;
Azer, Amir Shoukry ;
Khamis, Mohamed Moataz .
BMC ORAL HEALTH, 2023, 23 (01)
[39]   Evaluation of the marginal adaptation and debonding strength of two types of CAD-CAM implant-supported cement-retained crowns [J].
Nada Ahmed Ramzy ;
Amir Shoukry Azer ;
Mohamed Moataz Khamis .
BMC Oral Health, 23
[40]   The Influence of Three Different Digital Cement Spacers on the Marginal Gap Adaptation of Zirconia-Reinforced Lithium Silicate Crowns Fabricated by CAD-CAM System [J].
Ben-Izhack, Gil ;
Shely, Asaf ;
Naishlos, Sarit ;
Glikman, Ari ;
Frishman, Liad ;
Meirowitz, Avi ;
Dolev, Eran .
APPLIED SCIENCES-BASEL, 2021, 11 (22)