摘要
Aims:To compare the accuracy of marginal fit of CAD-CAM endocrown with two different preparation forms, i.e., endocrown with ferrule and endocrown without ferrule.Settings and Design:Various studies have opined on the impact of preparation form on the marginal fit of endocrown, but studies on the effect on the marginal fit of digitally milled endocrown with and without ferrule are sparse.Materials and Methods:Total of 30 typodont were sectioned 3 mm above the cemento-enamel junction, and central cavity was prepared to depict a severely destructed tooth. The typodonts were divided into two groups: Group 1 contained specimens for endocrown without ferrule (WoF); Group 2 contained specimens for endocrown with ferrule (WF). The typodonts were prepared based on standard preparation. The specimens were then scanned using intraoral scanner, and the stereolithography (STL) was generated. Endocrowns were designed in the Exocad software using a digital library. The STL file format is translated into millable data file format (CNC- Computer numerical control) in the inLAB MC X5 Milling machine. The marginal fit of endocrowns was then assessed in the stereomicroscope.Statistical Analysis:The data was analysed with a digital image analyser. The result was generated using a two-way ANOVA test. The significance level was set at P <= 0.05.Results:In the present study, the marginal fit of WoF showed a superior marginal fit than WF. A statistically significant difference was seen in the marginal fit of two endocrowns, with a higher marginal discrepancy observed in the endocrown with the ferrule. The P value for the difference in the means of the marginal gap without and with ferrule (-13.42) is zero. Maximum marginal gap of 96 micron is observed for with ferrule (WF) design at location B. Minimum marginal gap of 29 micron is observed for without ferrule (WoF) at location D.Conclusions:Endocrown without a ferrule can provide a better marginal fit and can contribute to the long-term survival of restoration.
引用
收藏
页码:74 / 79
页数:6
相关论文
共 50 条
  • [1] The influence of different CAD/CAM materials on the marginal fit of endocrown with different cavity depths (A comparative in-vitro study)
    Ewadh, Ali M.
    Jasim, Haider Hasan
    MATERIALS TODAY-PROCEEDINGS, 2022, 61 : 695 - 699
  • [2] Effect of different CAD-CAM materials on the marginal and internal adaptation of endocrown restorations: An in vitro study
    El Ghoul, Wiam A.
    Ozcan, Mutlu
    Ounsi, Hani
    Tohme, Hani
    Salameh, Ziad
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (01): : 128 - 134
  • [3] Marginal and Internal Fit of Monolithic Zirconia Crowns Fabricated by Using Two Different CAD-CAM Workflows: An In Vitro Study
    Cin, Vahap
    Izgi, Ayca Deniz
    Kale, Ediz
    Yilmaz, Burak
    PROSTHESIS, 2023, 5 (01): : 35 - 47
  • [4] Evaluation of the marginal and internal discrepancies of CAD-CAM endocrowns with different cavity depths: An in vitro study
    Shin, Yooseok
    Park, Sungho
    Park, Jeong-Won
    Kim, Kwang-Mahn
    Park, Young-Bum
    Roh, Byoung-Duck
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (01): : 109 - 115
  • [5] Effect of different intraoral scanning strategies on the marginal and internal fit of CAD-CAM inlay restorations: An in vitro study
    Salem, Mohamed M.
    Elmahy, Waleed A.
    Nasr, Dina M.
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (03): : 518.e1 - 518.e9
  • [6] Evaluation of marginal and internal fit of single crowns manufactured with an analog workflow and three CAD-CAM systems: A prospective clinical study
    Sanchez-Lara, Alejandro
    Hosney, Sherif
    Lampraki, Evangelina
    Conejo, Julian
    Blatz, Markus. B. B.
    Barmak, Abdul Basir
    Ercoli, Carlo
    Chochlidakis, Konstantinos
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (08): : 689 - 696
  • [7] An in vitro evaluation of marginal fit zirconia crowns fabricated by a CAD-CAM dental laboratory and a milling center
    Avi Meirowitz
    Yoli Bitterman
    Sharon Levy
    Eitan Mijiritsky
    Eran Dolev
    BMC Oral Health, 19
  • [8] The marginal fit of CAD-CAM zirconia cores with different proximal margin configurations
    Puntsag, O. E.
    Bae, E. K.
    Lee, J. H.
    Lee, K. W.
    BIOCERAMICS, VOL 19, PTS 1 AND 2, 2007, 330-332 : 1409 - +
  • [9] An in vitro evaluation of marginal fit zirconia crowns fabricated by a CAD-CAM dental laboratory and a milling center
    Meirowitz, Avi
    Bitterman, Yoli
    Levy, Sharon
    Mijiritsky, Eitan
    Dolev, Eran
    BMC ORAL HEALTH, 2019, 19 (1)
  • [10] In vitro evaluation of marginal discrepancy of monolithic zirconia restorations fabricated with different CAD-CAM systems
    Hamza, Tamer A.
    Sherif, Rana M.
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (06): : 762 - 766