Design and Fabrication of Orthokeratology Lens with Multi-Linear and Spherical Aberration Corrected for Myopia Control

被引:0
作者
Li, Zhengwang
Hong, Ruijin [1 ]
Zhang, Dawei
机构
[1] Univ Shanghai Sci & Technol, Engn Res Ctr Opt Instrument & Syst, Minist Educ, 516 Jungong Rd, Shanghai 200093, Peoples R China
基金
中国国家自然科学基金;
关键词
myopia; ortho-k lens; enhance centration; aberration elimination; PROGRESSION; PREVALENCE;
D O I
10.3390/photonics12010087
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Myopia, an increasingly grave public health concern, necessitates the implementation of various techniques for its management. These techniques predominantly comprise the employment of spectacles correction, orthokeratology (ortho-k), and soft bifocal and multifocal lenses. In the present study, a pioneering polish-free ortho-k lens was devised, featuring two reverse lines and three alignment lines, which, respectively, expedite the shaping process and enhance centration. The structural blueprint of the ortho-k lens, along with the simulation of fluorescence staining, was executed employing the FocalPoints software V7.0 (Advance Medical, Milan, Italy). Subsequently, lens aberration elimination was accomplished through ray tracing utilizing ZEMAX software V13.0 (Focus Software, Wixom, MI, USA). The fabrication of the lens was carried out via high-precision lathe turning using the UPC 100 Vision instrument (SCHNEIDER, Ratingen, Germany). The power profile of the ortho-k lens was measured using the CONTEST 2 apparatus (ROTLEX, Omer, Israel). The surface quality was observed under a 200x microscope (ZEISS, Oberkochen, Germany). The fitting of the lens was assessed through the utilization of both Slit-lamp microscopy (MediWorks, Shanghai, China) and Corneal topographer (Medmont E300, Melbourne, VIC, Australia)
引用
收藏
页数:13
相关论文
共 22 条
  • [1] CASE-CONTROL STUDY OF IDIOPATHIC RETINAL-DETACHMENT
    AUSTIN, KL
    PALMER, JR
    SEDDON, JM
    GLYNN, RJ
    ROSENBERG, L
    GRAGOUDAS, ES
    KAUFMAN, DW
    SHAPIRO, S
    [J]. INTERNATIONAL JOURNAL OF EPIDEMIOLOGY, 1990, 19 (04) : 1045 - 1050
  • [2] The effect of LASIK on best-corrected high- and low-contrast visual acuity
    Bailey, MD
    Olson, MD
    Bullimore, MA
    Jones, L
    Maloney, RK
    [J]. OPTOMETRY AND VISION SCIENCE, 2004, 81 (05) : 362 - 368
  • [3] Caroline P J, 2001, Cont Lens Anterior Eye, V24, P41, DOI 10.1016/S1367-0484(01)80008-4
  • [4] Orthokeratology practice in children in a university clinic in Hong Kong
    Chan, Ben
    Cho, Pauline
    Cheung, Sin Wan
    [J]. CLINICAL AND EXPERIMENTAL OPTOMETRY, 2008, 91 (05) : 453 - 460
  • [5] Charm J, 2017, CLIN OPTOM, V9, P33, DOI 10.2147/OPTO.S104507
  • [6] Astigmatic Changes in Orthokeratology
    Cheung, Sin Wan
    Cho, Pauline
    Chan, Ben
    [J]. OPTOMETRY AND VISION SCIENCE, 2009, 86 (12) : 1352 - 1358
  • [7] Subjective and objective assessments of the effect of orthokeratology - A cross-sectional study
    Cheung, SW
    Cho, P
    [J]. CURRENT EYE RESEARCH, 2004, 28 (02) : 121 - 127
  • [8] Correcting ocular spherical aberration with soft contact lenses
    Dietze, HH
    Cox, MJ
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2004, 21 (04) : 473 - 485
  • [9] The influence of limbal and scleral shape on scleral lens design
    Fadel, Daddi
    [J]. CONTACT LENS & ANTERIOR EYE, 2018, 41 (04) : 321 - 328
  • [10] Effects of orthokeratology on the progression of low to moderate myopia in Chinese children
    He, Mengmei
    Du, Yaru
    Liu, Qingyu
    Ren, Chengda
    Liu, Junling
    Wang, Qianyi
    Li, Li
    Yu, Jing
    [J]. BMC OPHTHALMOLOGY, 2016, 16