Jugular Venous Oxygen and Lactate Parameters for Predicting Early Cognitive Dysfunction after Off-Pump Coronary Artery Bypass Grafting: A Prospective Observational Study

被引:0
作者
Singh, Pooja [1 ]
Anchukandan, Ramees A. [1 ]
Karna, Sunaina T. [1 ]
Niwariya, Yogesh [2 ]
Waindeskar, Vaishali [1 ]
Kumar, Harish [1 ]
Padala, S. R. A. N. Bhushanam [1 ]
Kiran, Molli [1 ]
机构
[1] All India Inst Med Sci, Dept Anesthesiol, Bhopal, Madhya Pradesh, India
[2] All India Inst Med Sci, Dept Cardiothorac & Vasc Surg, Bhopal, Madhya Pradesh, India
关键词
Postoperative delirium; postoperative cognitive dysfunction; off-pump coronary artery bypass grafting; jugulo-venous oxygen indices; jugulo-venous lactate indices; CEREBRAL-ISCHEMIA; ON-PUMP; SATURATION; SURGERY; METAANALYSIS; DELIRIUM; DECLINE;
D O I
10.4103/aian.aian_584_24
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Objectives:The quality of life may be negatively impacted by postoperative cognitive dysfunction (POCD) following off-pump coronary artery bypass grafting (OPCAB). It is still unclear how useful the jugular venous lactate and oxygen parameters are in predicting POCD following OPCAB. Methods:This prospective observational study was conducted over a period of 15 months and included 54 individuals. It sought to determine the sensitivity and specificity of jugular venous lactate and oxygen parameters for early POCD prediction in patients undergoing OPCAB. Neuropsychological tests were conducted to assess baseline cognitive function. Under ultrasound guidance, the jugular bulb was cannulated. The jugular venous lactate and oxygen parameters were measured at the time of surgery, following each graft, and 6 and 24 h later. Confusion assessment method-intensive care unit score was assessed on the third postoperative day for postoperative delirium (POD). POCD was defined as a composite Z score >= 1.96 or two Z scores in individual tests at 1 week. The jugular venous lactate and oxygen parameters of the Decline (D) group were compared to those of the Normal (N) group. Receiver operating characteristic curves were used to assess the diagnostic efficacy of derived variables. Results:The incidence of POD and POCD was 18.5% and 11.1%, respectively. At T3, all derived variables showed a significant increase, although the arterio-jugular venous lactate difference (AJDL) and modified lactate oxygen index (mLOI) were substantially greater at T3 in group D compared to group N. When predicting POCD, mLOI demonstrated the highest sensitivity at 72.22%, while AJDL showed the highest specificity at 90.7%. Conclusions:For prediction of early POCD in patients undergoing elective OPCAB, mLOI had highest sensitivity, while AJDL had high specificity.
引用
收藏
页码:79 / 86
页数:10
相关论文
共 50 条
[41]   Twenty-Year Experience With Off-Pump Coronary Artery Bypass Grafting and Early Postoperative Angiography [J].
Kim, Ki-Bong ;
Choi, Jae Woong ;
Oh, Se Jin ;
Hwang, Ho Young ;
Kim, Jun Sung ;
Choi, Jae-Sung ;
Lim, Cheong .
ANNALS OF THORACIC SURGERY, 2020, 109 (04) :1112-1119
[42]   Analysis of Myocardial Ischemia Parameters after Coronary Artery Bypass Grafting with Minimal Extracorporeal Circulation and a Novel Microplegia versus Off-Pump Coronary Artery Bypass Grafting [J].
Koechlin, Luca ;
Zenklusen, Urs ;
Doebele, Thomas ;
Rrahmani, Bejtush ;
Gahl, Brigitta ;
Schaeffer, Thibault ;
Berdajs, Denis ;
Eckstein, Friedrich S. ;
Reuthebuch, Oliver .
MEDIATORS OF INFLAMMATION, 2020, 2020
[43]   A Risk Score for Predicting Long-Term Mortality Following Off-Pump Coronary Artery Bypass Grafting [J].
Urbanowicz, Tomasz Kamil ;
Michalak, Michal ;
Gasecka, Aleksandra ;
Olasinska-Wisniewska, Anna ;
Perek, Bartlomiej ;
Rodzki, Michal ;
Bocianski, Michal ;
Jemielity, Marek .
JOURNAL OF CLINICAL MEDICINE, 2021, 10 (14)
[44]   Results of coronary artery bypass grafting with left ventricular dysfunction (comparison of off-pump versus on-pump) [J].
Houssa, M. Ait ;
Moutakiallah, Y. ;
Abdou, A. ;
Selkane, C. ;
Amahzoune, B. ;
Drissi, M. ;
Raissouni, M. ;
El Bekkali, Y. ;
Azendour, H. ;
Boulahya, A. .
ANNALES DE CARDIOLOGIE ET D ANGEIOLOGIE, 2013, 62 (04) :241-247
[45]   Long-Term Survival After On-Pump and Off-Pump Coronary Artery Bypass Grafting [J].
Squiers, John J. ;
Schaffer, Justin M. ;
Banwait, Jasjit K. ;
Ryan, William H. ;
Mack, Michael J. ;
DiMaio, J. Michael .
ANNALS OF THORACIC SURGERY, 2022, 113 (06) :1943-1952
[46]   The Incidence of Atrial Fibrillation after On-Pump Versus Off-Pump Coronary Artery Bypass Grafting [J].
Arslan, Gokhan ;
Erol, Gokhan ;
Kartal, Hakan ;
Demirdas, Ertan ;
Bolcal, Cengiz .
HEART SURGERY FORUM, 2021, 24 (04) :E645-E650
[47]   Preoperative right ventricular dysfunction requires high vasoactive and inotropic support during off-pump coronary artery bypass grafting [J].
Kunigo, Tatsuya ;
Yoshikawa, Yusuke ;
Yamamoto, Shuji ;
Yamakage, Michiaki .
GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2021, 69 (06) :934-942
[48]   Effects of ischemic preconditioning and synchronized coronary venous retroperfusion in an off-pump coronary artery bypass grafting model [J].
Hatori, N ;
Segawa, D ;
Hinokiyama, K ;
Kimura, T ;
Iizuka, Y ;
Ochi, M ;
Tanaka, S .
ARTIFICIAL ORGANS, 2001, 25 (01) :47-52
[49]   Risk-adjusted analysis of long-term outcomes after on- versus off-pump coronary artery bypass grafting [J].
Deutsch, Marcus-Andre ;
Zittermann, Armin ;
Renner, Andre ;
Schramm, Rene ;
Gotte, Julia ;
Borgermann, Jochen ;
Fox, Henrik ;
Rojas, Sebastian, V ;
Gyoten, Takayuki ;
Morshuis, Michiel ;
Koster, Andreas ;
Hulde, Nikolai ;
Hinse, Dennis ;
Hakim-Meibodi, Kavous ;
Gummert, Jan F. .
INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2021, 33 (06) :857-865
[50]   The Canadian off-pump coronary artery bypass graft registry: A one-year prospective comparison with on-pump coronary artery bypass grafting [J].
Lamy, A ;
Farrokhyar, F ;
Kent, R ;
Wang, XY ;
Smith, KM ;
Mullen, JC ;
Carrier, M ;
Cheung, A ;
Baillot, R .
CANADIAN JOURNAL OF CARDIOLOGY, 2005, 21 (13) :1175-1181