Blood Pressure Difference Between Cuff Inflation and Deflation by Auscultatory Method: Impact of Hypertension Grade

被引:0
作者
Coccina, Francesca [1 ]
Pizzicannella, Jacopo [2 ]
Trubiani, Oriana [1 ]
Pierdomenico, Sante D. [1 ]
机构
[1] Univ Gabriele dAnnunzio, Dept Innovat Technol Med & Dent, I-66100 Chieti, Italy
[2] Univ Gabriele dAnnunzio, Dept Engn & Geol, I-66100 Chieti, Italy
关键词
blood pressure; measurement; auscultatory method; hypertension; PAIN PERCEPTION; MANAGEMENT;
D O I
10.3390/diagnostics15060687
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The aim of this study was to evaluate blood pressure (BP) difference between cuff inflation and deflation and to investigate whether hypertension grade and patients' characteristics could be influential. Methods: We selected 328 asymptomatic patients, 219 with mild systolic/diastolic hypertension, 75 with moderate systolic/diastolic hypertension and 34 with severe systolic/diastolic hypertension. Results: Hypertension grade was a determinant of the difference between systolic/diastolic BP during cuff inflation and deflation; the difference was progressively and significantly higher from mild to moderate to severe hypertension (1.80 +/- 1.03/1.21 +/- 0.56 vs. 5.32 +/- 1.09/3.04 +/- 0.81 vs. 9.74 +/- 1.46/4.88 +/- 0.73 mmHg, respectively (all differences were significant). Age, gender, body mass index, smoking habits and laboratory parameters were not associated with BP differences. The observed differences led to a reclassification of 24% of patients with moderate and 32% of patients with severe hypertension to a lower grade, but all were classified as hypertensive patients during cuff inflation. Conclusions: Hypertension grade influences the difference in systolic/diastolic BP during cuff inflation and deflation. This difference leads to a reclassification of hypertension grade during cuff inflation within the hypertensive range but does not influence the definition of hypertensive status. Future studies are needed to confirm whether the differences in systolic/diastolic BP between cuff inflation and deflation are due to BP increases induced by sympathetic activation, as well as a potential different behavior of the brachial artery during closing or opening, or both.
引用
收藏
页数:8
相关论文
共 50 条
[11]   Using a large cuff reduces the difference between peripheral and central blood pressure readings. The BP-CUFF study [J].
Baguet, Jean-Philippe ;
de Poli, Fabien ;
Sosner, Philippe ;
Jaboureck, Olivier ;
Nait-Saidi, Lyassine ;
Vautrin, Estelle ;
Barone-Rochette, Gilles .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 170 (02) :E43-E44
[12]   SYSTEMATIC DIFFERENCE BETWEEN BLOOD-PRESSURE READINGS CAUSED BY CUFF TYPE [J].
BOVET, P ;
HUNGERBUHLER, P ;
QUILINDO, J ;
GRETTVE, ML ;
WAEBER, B ;
BURNAND, B .
HYPERTENSION, 1994, 24 (06) :786-792
[13]   Differences in mean arterial pressure of young and elderly people measured by oscilometry during inflation and deflation of the arm cuff [J].
Fabian, Vratislav ;
Havlik, Jan ;
Dvorak, Jan ;
Kremen, Vaclav ;
Sajgalik, Pavol ;
Bellamy, Valentin ;
Schirger, John A. ;
Sovka, Pavel ;
Johnson, Bruce D. .
BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2016, 61 (06) :611-621
[14]   Reactive rise in blood pressure upon cuff inflation: cuff inflation at the arm causes a greater rise in pressure than at the wrist in hypertensive patients [J].
Charmoy, Alexia ;
Wuerzner, Gregoire ;
Ruffieux, Christiane ;
Hasler, Christopher ;
Cachat, Francois ;
Waeber, Bernard ;
Burnier, Michel .
BLOOD PRESSURE MONITORING, 2007, 12 (05) :275-280
[15]   The impact of sphygmomanometer placement and cuff placement on blood pressure measurements [J].
Zhu, Xiao-Yong ;
Zhang, Pu-Hua ;
Huang, Wen-Yin ;
Huang, Wan ;
Tang, Xin-Hu ;
Yu, Hua ;
Wang, Su-Nan .
FRONTIERS IN CARDIOVASCULAR MEDICINE, 2024, 11
[16]   Blood Pressure Assessed through Oscillometric and Auscultatory Method Before and After Exercise in the Elderly [J].
de Lima Scher, Luria Melo ;
Ferriolli, Eduardo ;
Moriguti, Julio C. ;
Lima, Nereida K. C. .
ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2010, 94 (05) :656-662
[17]   Cuff inflation during ambulatory blood pressure monitoring and heart rate [J].
Skov-Madsen, Mia ;
Svensson, My ;
Christensen, Jeppe Hagstrup .
INTEGRATED BLOOD PRESSURE CONTROL, 2008, 1 :15-19
[18]   Hypertension Prevalence and Control: Impact of Method of Blood Pressure Measurement [J].
Cloutier L. ;
Schiffrin E.L. .
Current Cardiovascular Risk Reports, 2012, 6 (4) :267-273
[19]   Difference in Blood Pressure Measurements Between Arms: Methodological and Clinical Implications [J].
Clark, Christopher E. .
CURRENT PHARMACEUTICAL DESIGN, 2015, 21 (06) :737-743
[20]   Wrist Cuff Method Determines Diastolic Pressure in Dual Cuff Blood Pressure System [J].
Jilek, Jiri ;
Stork, Milan .
2015 INTERNATIONAL CONFERENCE ON APPLIED ELECTRONICS (AE), 2015, :85-88