Analysis of the safety and efficacy of flow diverter device in the treatment of tandem aneurysms in the internal carotid artery

被引:0
|
作者
Wan, Jun [1 ,2 ]
Xu, Ligang [2 ]
Jiang, Yeqing [3 ]
Zhang, Lei [2 ]
Wang, Zhenyu [2 ]
Zhang, Xiaolong [3 ]
Wang, Shengzhang [1 ,4 ]
机构
[1] Fudan Univ, Acad Engn & Technol, Shanghai, Peoples R China
[2] Fudan Univ, Jingan Dist Cent Hosp, Dept Intervent Radiol, Shanghai, Peoples R China
[3] Fudan Univ, Dept Radiol, Huashan Hosp, Shanghai, Peoples R China
[4] Fudan Univ, Inst Biomech, Dept Aeronaut & Astronaut, Shanghai, Peoples R China
来源
FRONTIERS IN NEUROLOGY | 2025年 / 16卷
关键词
intracranial aneurysms; tandem aneurysms; flow diverter device; pipeline; Tubridge; INTRACRANIAL ANEURYSMS; ENDOVASCULAR TREATMENT;
D O I
10.3389/fneur.2025.1462108
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective To investigate the clinical efficacy and safety of flow diverter device (FDD) in the treatment of tandem aneurysms in the internal carotid artery. Materials and methods This study was a retrospectively observational study involving two neurointerventional centers. Sixteen Patients with tandem aneurysms in the internal carotid artery treated with FDD and Digital Subtraction Angiography (DSA) follow-up in Huashan Hospital Affiliated with Fudan University and Jing'an District Central Hospital Affiliated with Fudan University from 2020.08 to 2023.12 were included. The outcomes included the angiographic occlusion rate of aneurysms, complications, and the modified Rankin Scale score. The risk factors of complete occlusion of tandem aneurysms were explored by logistic regression analysis. Results A total of 38 aneurysms were included, including 21 aneurysms of 8 patients in the Pipeline Embolization Device (PED) group and 17 aneurysms of 8 patients in the Tubridge Flow Diverter (TFD) group. A total of 16 FDD stents were implanted, 8 in each PED and TFD group, with a technical success rate of 100%. The median value of maximum aneurysm diameter (D-max) was 4.27 (3.57-5.41) mm. Among them, 28 aneurysms had a maximum diameter of <5 mm (73.7%), 10 aneurysms had a maximum diameter of 5-15 mm (26.3%). All patients were followed up clinically for a median of 25.5 months (15.5-28.7 months). There were no deaths and symptomatic complications. The modified Rankin Scale scores (mRS) of 16 patients were all less than 2. All patients were examined by angiography with a median of 14 months (6-27 months). Among them, there were 5 Consensus Grading Scale for Endovascular Aneurysm Occlusion (CGSFEAO) grade 5 (13.2%), 1 CGSFEAO grade 4 (2.6%), 1 CGSFEAO grade 2 (2.6%) and 31 CGSFEAO grade 0 (81.6%). The complete occlusion rate of intracranial aneurysm in the whole study was 81.6%, including 85.7% in the PED group and 76.5% in the TFD group, and there was no significant statistical difference between the two groups. Statistically significant variables were not found in univariate logistic regression analysis. Conclusion FDD is safe and effective in treating tandem aneurysms in the internal carotid artery with a high occlusion rate and few complications. TFD is comparable to PED in the treatment of intracranial tandem aneurysms.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Treatment of Traumatic Internal Carotid Artery Aneurysm by Flow-Diverter: A Single-Center Experience
    Dogan, Adem
    Durmaz, Mehmet Ozan
    Yuce, Gokhan
    Ezgu, Mehmet Can
    NEUROCHIRURGIE, 2022, 68 (06) : E60 - E67
  • [22] Effect and safety of Tubridge flow diverter in the treatment of unruptured intracranial aneurysms
    Li, Li
    Shao, Qiu-Ji
    Li, Tian-Xiao
    Wang, Zi-Liang
    Zhang, Kun
    Gao, Bu-Lang
    MEDICINE, 2022, 101 (50) : E31672
  • [23] Tirofiban as treatment for acute retinal artery occlusion following internal carotid artery flow diverter implantation
    Pierro, Luisa
    La Spina, Carlo
    Corvi, Federico
    Cicinelli, Maria V.
    Scomazzoni, Francesco
    Cappelletti, Alberto
    Bandello, Francesco
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2016, 26 (04) : E74 - E76
  • [24] Quantitative flow measurement after placing a flow diverter for a distal internal carotid artery aneurysm
    Chen, Chien-Wei
    Wong, Ho-Fai
    Ye, Yu-Ling
    Chen, Yao-Liang
    Chen, Wei-Liang
    Ou, Chang-Hsien
    Tsai, Yuan-Hsiung
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2017, 9 (12) : 1238 - +
  • [25] Extracranial Visceral Artery Aneurysms/Pseudoaneurysms Repaired with Flow Diverter Device Developed for Cerebral Aneurysms: Preliminary Results
    Colombi, Davide
    Bodini, Flavio Cesare
    Bossalini, Margherita
    Rossi, Beatrice
    Michieletti, Emanuele
    ANNALS OF VASCULAR SURGERY, 2018, 53 : 272.e1 - 272.e9
  • [26] A novel flow diverter device (Tubridge) for the treatment of intracranial aneurysms: a systematic review and meta-analysis
    Yingjun Fan
    Jun Lei
    Fan Fei
    Jun Liu
    Yanhui Liu
    Neurosurgical Review, 46
  • [27] Flow Diverter Therapy Using a Pipeline Embolization Device for 100 Unruptured Large and Giant Internal Carotid Artery Aneurysms in a Single Center in a Japanese Population
    Oishi, Hidenori
    Teranishi, Kosuke
    Yatomi, Kenji
    Fujii, Takashi
    Yamamoto, Munetaka
    Arai, Hajime
    NEUROLOGIA MEDICO-CHIRURGICA, 2018, 58 (11) : 461 - 467
  • [28] Flow diverter manages very small aneurysm of the internal carotid artery
    Lee, Chien-Hui
    Luo, Chao-Bao
    Lai, Yen-Chun
    Chang, Feng-Chi
    Lin, Chung-Jung
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2022, 85 (07) : 754 - 758
  • [29] Flow diverter for the treatment of large (> 10 mm) vertebral artery dissecting aneurysms
    Lee, Woosung
    Han, Hyun Jin
    Kim, Junhyung
    Park, Keun Young
    Kim, Yong Bae
    Jang, Chang Ki
    Chung, Joonho
    ACTA NEUROCHIRURGICA, 2022, 164 (05) : 1247 - 1254
  • [30] Pipeline Embolization Device for Treatment of Extracranial Internal Carotid Artery Pseudoaneurysms: A Multicenter Evaluation of Safety and Efficacy
    Akinduro, Oluwaseun O.
    Gopal, Neethu
    Hasan, Tasneem F.
    Nourollah-Zadeh, Emad
    Vakharia, Kunal
    De Leacy, Reade
    Burkhardt, Jan-Karl
    Yamamoto, Junichi
    Mocco, J.
    Castilla, Leonardo Rangel
    Kan, Peter Tze Man
    Boulos, Alan
    Levy, Elad
    Tawk, Rabih G.
    NEUROSURGERY, 2020, 87 (04) : 770 - 778