Consensus instability equations for routine coagulation tests

被引:0
|
作者
Gomez Rioja, Ruben [1 ]
Caballero Garralda, Andrea [2 ]
Comas Reixach, Immaculada [2 ]
Garcia Miralles, Carlos [3 ]
Llopis Diaz, Maria Antonia [4 ]
Martinez Espartosa, Debora [5 ]
Nicolas de Blas, Reyes [6 ]
Panades Turro, Mariona [7 ]
Puigvi Fernandez, Laura [8 ]
Rodelgo Jimenen, Laura [9 ]
Sufrate-Vergara, Berta [10 ]
Ventura Orriols, Emma [11 ]
机构
[1] La Paz Cantoblanco Carlos III Hosp, Hematol Dept, Madrid, Spain
[2] Vall dHebron Hosp, Dept Clin Biochem, Barcelona, Spain
[3] Parc Tauli Hosp Univ, Dept Clin Biochem, Sabadell, Spain
[4] Catalonian Hlth Inst, Barcelona, Spain
[5] Univ Navarra Clin, Dept Biochem, Navarra, Spain
[6] Ramon y Cajal Univ Hosp, Dept Clin Biochem, Madrid, Spain
[7] Spanish Soc Lab Med SEQCML, Barcelona, Spain
[8] CLILAB Diagnost, Operations, Barcelona, Spain
[9] Hosp Clin San Carlos, Lab Med Inst IML, Madrid, Spain
[10] La Paz Cantoblanco Carlos III Hosp, Lab Med, Madrid, Spain
[11] Hosp St Joan Deu, Extraanalyt Dept Lab, Esplugas de Llobregat, Barcelona, Spain
关键词
sample stability; preanalytical phase; stability equation; coagulation; PARTIAL THROMBOPLASTIN TIME; PROTHROMBIN TIME; WHOLE-BLOOD; PREANALYTICAL VARIABLES; ROOM-TEMPERATURE; STORAGE; STABILITY; SAMPLES; PLASMA; INR;
D O I
10.1515/cclm-2025-0117
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives The stability of plasma samples for basic coagulation tests, prothrombin time (PT) and activated partial thromboplastin time (aPTT), has been widely studied. Recently, the Clinical and Laboratory Standards Institute (CLSI) updated its recommendations, extending the acceptable time frame for aPTT. These guidelines are based on experimental studies, which define limits according to different maximum permissible error (MPE) criteria. This study compiles raw data from 43 studies published over the last 30 years to develop a consensus instability equation that describes degradation independently of specific study parameters.Methods A critical literature review was performed by collecting studies that included experimental stability data for PT, aPTT and the main procoagulant factors. The raw data of percentage deviation (PD%), time, and seven classification variables related to sample collection and handling were analysed. A regression model through the origin was applied to derive global instability equations and to assess influencing variables.Results In frozen samples, PT and aPTT showed similar stability, with an average prolongation of 0.8 % per month. In non-frozen samples, tube handling affected stability more than storage temperature. The consensus equation for PT showed a linear average deterioration of 2.9 % per day, but model strength was limited. For aPTT, the consensus equation fitted better to a logarithmic decay model and predicted prolongations of 6.1 and 10 % at 6 and 24 h, respectively.Conclusions The consensus instability equations obtained in this review provide a robust model for assessing coagulation tests stability, aligning with expert recommendations. These equations improve the understanding of sample degradation and systematic error quantification.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Comparison of capillary and venous blood sampling for routine coagulation assays
    Fliervoet, Lies A. L.
    Groenestege, Wouter M. Tiel
    Huisman, Albert
    CLINICAL BIOCHEMISTRY, 2022, 104 : 30 - 35
  • [32] Homogeneity and Stability Evaluation of External Quality Assessment Control Materials for Four Coagulation Tests
    Yuan, Huimin
    Gao, Zhiqi
    Zhang, Jianping
    Yue, Yuhong
    Zhang, Shunli
    Zhang, Rui
    CLINICAL LABORATORY, 2021, 67 (05) : 1221 - 1227
  • [33] Usefulness of standard plasma coagulation tests in the management of perioperative coagulopathic bleeding: is there any evidence?
    Haas, T.
    Fries, D.
    Tanaka, K. A.
    Asmis, L.
    Curry, N. S.
    Schoechl, H.
    BRITISH JOURNAL OF ANAESTHESIA, 2015, 114 (02) : 217 - 224
  • [34] Determination of in vitro stability of routine haematinics tests using EFLM standards and the CRESS checklist
    Williams, Robert D.
    Duff, Christopher J.
    Yates, Alexandra
    ANNALS OF CLINICAL BIOCHEMISTRY, 2023, 60 (06) : 367 - 373
  • [35] Overwiew of the Coagulation System and laboratory tests for its study
    Guerrero, Belsy
    Lopez, Mercedes
    INVESTIGACION CLINICA, 2015, 56 (04): : 432 - 454
  • [36] Routine Coagulation Tests in Patients With Nonvalvular Atrial Fibrillation Under Dabigatran and Rivaroxaban Therapy: An Affordable and Reliable Strategy?
    Silva, Vanessa M.
    Scanavacca, Mauricio
    Darrieux, Francisco
    Cavalheiro, Cyrillo
    Strunz, Celia C.
    CLINICAL AND APPLIED THROMBOSIS-HEMOSTASIS, 2019, 25
  • [37] Comparison of point-of-care hemostatic assays, routine coagulation tests, and outcome scores in critically ill patients
    Larsson, A.
    Tynngard, N.
    Kander, T.
    Bonnevier, J.
    Schott, U.
    JOURNAL OF CRITICAL CARE, 2015, 30 (05) : 1032 - 1038
  • [38] Inappropriateness of fresh frozen plasma for abnormal coagulation tests
    Pybus, S.
    MacCormac, A.
    Houghton, A.
    Martlew, V.
    Thachil, J.
    JOURNAL OF THE ROYAL COLLEGE OF PHYSICIANS OF EDINBURGH, 2012, 42 (04) : 294 - 300
  • [39] Comparison of Standard and Global Coagulation Tests in Hemodialysis Patients
    Divyaveer, Smita
    Chahal, Sarah
    Kashyap, Madhuri
    Premkumar, Madhumita
    Kekan, Kushal
    Sen, Arunima
    Prajapati, Kanchan
    Chauhan, Prabhat
    Bansal, Ritika
    Prabhahar, Arun
    Ahluwalia, Jasmina
    Kumar, Narender
    Mallik, Nabhajit
    Zohmangaihi, Deepy
    Kohli, Harbir Singh
    INDIAN JOURNAL OF NEPHROLOGY, 2025, 35 (02) : 259 - 264
  • [40] Retrospective comparison of standard clotting tests and novel clot waveform parameters in dogs using the turbidimetric ACL-TOP CTS 300 coagulation analyzer
    Yagneswar, Hamsini
    Todd, Jeffrey M.
    Sharkey, Leslie C.
    Rendahl, Aaron
    Tart, Kelly
    JOURNAL OF VETERINARY DIAGNOSTIC INVESTIGATION, 2018, 30 (06) : 868 - 877