Cartilage defect identification on computed tomography arthrography in equine fetlock: Ex-vivo study

被引:0
|
作者
Nocera, Irene [1 ]
Di Franco, Chiara [2 ]
Marcucci, Elisa [3 ]
Puccinelli, Caterina [4 ]
Sala, Giulia [4 ,5 ]
Sgorbini, Micaela [4 ]
Citi, Simonetta [4 ]
机构
[1] St Anna Sch Adv Studies, Inst Hlth Sci, Via Santa Cecilia 3, Pisa, Italy
[2] CNR San Cataldo Res Area, Inst Clin Physiol, Pisa, Italy
[3] Univ Bologna, Dept Vet Med Sci DIMEVET, Via Tolara 50, I-40064 Bologna, Italy
[4] Vet Teaching Hosp Mario Modenato, Dept Vet Sci, Via Livornese Snc, Pisa, Italy
[5] Univ Pisa, Ctr Ric Agroambientali E Avanzi, Pisa, Italy
关键词
Computed tomography arthrography; Contrast medium; Arthroscopy; Cartilage defect; CT-ARTHROGRAPHY; CORRELATION-COEFFICIENTS; THOROUGHBRED RACEHORSES; THICKNESS; RADIOGRAPHY; JOINT; OSTEOARTHRITIS; PATHOLOGY; ANATOMY; HIPS;
D O I
10.1016/j.rvsc.2025.105548
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
CT arthrography (CTA) for evaluating cartilage defects would be beneficial in clinical practice. Since the contrast medium (CM) volume is often driven by operator experience, the aim was to evaluate the minimum volume of iodinated CM for CTA sufficient to identify iatrogenic cartilage defects in horse fetlock. The study was conducted on ex-vivo 32 distal limbs from adult horses collected at slaughter. Iatrogenic cartilage defects were arthroscopically made on fetlock, at 5 predetermined locations. Subsequently, CT scans were performed, according to the following protocol: precontrast scan, followed by subsequent scans with incremental volumes of CM, ranging from 2,5-40 ml (total of 10 scans per fetlock). Then, the cartilage defects were measured macroscopically using a calliper. CTA scans were evaluated by a single operator, and defects were assessed for presence/absence and volume measures. Data were expressed as median and interquartile values. The association between CT scan assessments and different CM volumes was examined with chi-square test. The correlation between CT scans and macroscopic assessments was evaluated using Spearman's coefficient. Significance was set at a p-value <0.05. Twenty millilitres of CM were required to visualize 100 % of the defects, regardless of the location. A weak correlation was found between the defects' volume on macroscopic and CT scan assessment. Twenty millilitres of CM was sufficient to identify cartilage defects on the fetlock articular surface, supporting the conscious use of CM adequate for specific diagnostic purposes.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Thickness distribution of the glenohumeral joint cartilage: a quantitative study using computed tomography
    Zumstein, Valentin
    Kraljevic, Marko
    Conzen, Annemarie
    Hoechel, Sebastian
    Mueller-Gerbl, Magdalena
    SURGICAL AND RADIOLOGIC ANATOMY, 2014, 36 (04) : 327 - 331
  • [42] Root Canal Morphology and Configuration of 179 Maxillary First Molars by Means of Micro-computed Tomography: An Ex Vivo Study
    Briseno-Marroquin, Benjamin
    Pague, Frank
    Maier, Karolin
    Willershausen, Brita
    Wolf, Thomas Gerhard
    JOURNAL OF ENDODONTICS, 2015, 41 (12) : 2008 - 2013
  • [43] Computed Tomography-Mediated Registration of Trapeziometacarpal Articular Cartilage Using Intraarticular Optical Coherence Tomography and Cryomicrotome Imaging: A Cadaver Study
    Cernohorsky, Paul
    Strackee, Simon D.
    Streekstra, Geert J.
    van den Wijngaard, Eroen P.
    Spaan, Jos A. E.
    Siebes, Maria
    van Leeuwen, Ton G.
    de Bruin, Daniel M.
    CARTILAGE, 2021, 13 (1_SUPPL) : 563S - 570S
  • [44] Morphometric Grading of Osteoarthritis by Optical Coherence Tomography - An Ex Vivo Study
    Nebelung, Sven
    Marx, Ulrich
    Brill, Nicolai
    Arbab, Darius
    Quack, Valentin
    Jahr, Holger
    Tingart, Markus
    Zhou, Bei
    Stoffel, Marcus
    Schmitt, Robert
    Rath, Bjoern
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2014, 32 (10) : 1381 - 1388
  • [45] Thickness distribution of the glenohumeral joint cartilage: a quantitative study using computed tomography
    Valentin Zumstein
    Marko Kraljević
    Annemarie Conzen
    Sebastian Hoechel
    Magdalena Müller-Gerbl
    Surgical and Radiologic Anatomy, 2014, 36 : 327 - 331
  • [46] Pathology of callosal damage in ALS: An ex-vivo, 7 T diffusion tensor MRI study
    Cardenas, Agustin M.
    Sarlls, Joelle E.
    Kwan, Justin Y.
    Bageac, Devin
    Gala, Zachary S.
    Danielian, Laura E.
    Ray-Chaudhury, Abhik
    Wang, Hao-Wei
    Miller, Karla L.
    Foxley, Sean
    Jbabdi, Saad
    Welsh, Robert C.
    Floeter, Mary Kay
    NEUROIMAGE-CLINICAL, 2017, 15 : 200 - 208
  • [47] Correlation of Subchondral Bone Density and Structure from Plain Radiographs with Micro Computed Tomography Ex Vivo
    Jukka Hirvasniemi
    Jérôme Thevenot
    Harri T. Kokkonen
    Mikko A. Finnilä
    Mikko S. Venäläinen
    Timo Jämsä
    Rami K. Korhonen
    Juha Töyräs
    Simo Saarakkala
    Annals of Biomedical Engineering, 2016, 44 : 1698 - 1709
  • [48] Micro-Scale Distribution of CA4+ in Ex vivo Human Articular Cartilage Detected with Contrast-Enhanced Micro-Computed Tomography Imaging
    Karhula, Sakari S.
    Finnila, Mikko A.
    Freedman, Jonathan D.
    Kauppinen, Sami
    Valkealahti, Maarit
    Lehenkari, Petri
    Pritzker, Kenneth P. H.
    Nieminen, Heikki J.
    Snyder, Brian D.
    Grinstaff, Mark W.
    Saarakkala, Simo
    FRONTIERS IN PHYSICS, 2017, 5
  • [49] Correlation of Subchondral Bone Density and Structure from Plain Radiographs with Micro Computed Tomography Ex Vivo
    Hirvasniemi, Jukka
    Thevenot, Jerome
    Kokkonen, Harri T.
    Finnila, Mikko A.
    Venalainen, Mikko S.
    Jamsa, Timo
    Korhonen, Rami K.
    Toyras, Juha
    Saarakkala, Simo
    ANNALS OF BIOMEDICAL ENGINEERING, 2016, 44 (05) : 1698 - 1709
  • [50] Computed Tomographic Imaging of Subchondral Fatigue Cracks in the Distal End of the Third Metacarpal Bone in the Thoroughbred Racehorse Can Predict Crack Micromotion in an Ex-Vivo Model
    Dubois, Marie-Soleil
    Morello, Samantha
    Rayment, Kelsey
    Markel, Mark D.
    Vanderby, Ray, Jr.
    Kalscheur, Vicki L.
    Hao, Zhengling
    McCabe, Ronald P.
    Marquis, Patricia
    Muir, Peter
    PLOS ONE, 2014, 9 (07):