Cartilage defect identification on computed tomography arthrography in equine fetlock: Ex-vivo study

被引:0
|
作者
Nocera, Irene [1 ]
Di Franco, Chiara [2 ]
Marcucci, Elisa [3 ]
Puccinelli, Caterina [4 ]
Sala, Giulia [4 ,5 ]
Sgorbini, Micaela [4 ]
Citi, Simonetta [4 ]
机构
[1] St Anna Sch Adv Studies, Inst Hlth Sci, Via Santa Cecilia 3, Pisa, Italy
[2] CNR San Cataldo Res Area, Inst Clin Physiol, Pisa, Italy
[3] Univ Bologna, Dept Vet Med Sci DIMEVET, Via Tolara 50, I-40064 Bologna, Italy
[4] Vet Teaching Hosp Mario Modenato, Dept Vet Sci, Via Livornese Snc, Pisa, Italy
[5] Univ Pisa, Ctr Ric Agroambientali E Avanzi, Pisa, Italy
关键词
Computed tomography arthrography; Contrast medium; Arthroscopy; Cartilage defect; CT-ARTHROGRAPHY; CORRELATION-COEFFICIENTS; THOROUGHBRED RACEHORSES; THICKNESS; RADIOGRAPHY; JOINT; OSTEOARTHRITIS; PATHOLOGY; ANATOMY; HIPS;
D O I
10.1016/j.rvsc.2025.105548
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
CT arthrography (CTA) for evaluating cartilage defects would be beneficial in clinical practice. Since the contrast medium (CM) volume is often driven by operator experience, the aim was to evaluate the minimum volume of iodinated CM for CTA sufficient to identify iatrogenic cartilage defects in horse fetlock. The study was conducted on ex-vivo 32 distal limbs from adult horses collected at slaughter. Iatrogenic cartilage defects were arthroscopically made on fetlock, at 5 predetermined locations. Subsequently, CT scans were performed, according to the following protocol: precontrast scan, followed by subsequent scans with incremental volumes of CM, ranging from 2,5-40 ml (total of 10 scans per fetlock). Then, the cartilage defects were measured macroscopically using a calliper. CTA scans were evaluated by a single operator, and defects were assessed for presence/absence and volume measures. Data were expressed as median and interquartile values. The association between CT scan assessments and different CM volumes was examined with chi-square test. The correlation between CT scans and macroscopic assessments was evaluated using Spearman's coefficient. Significance was set at a p-value <0.05. Twenty millilitres of CM were required to visualize 100 % of the defects, regardless of the location. A weak correlation was found between the defects' volume on macroscopic and CT scan assessment. Twenty millilitres of CM was sufficient to identify cartilage defects on the fetlock articular surface, supporting the conscious use of CM adequate for specific diagnostic purposes.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Micro-computed tomography reveals high-density mineralised protrusions and microstructural lesions in equine stifle joint articular cartilage
    Ducrocq, Mathilde
    Kamus, Louis
    Richard, Helene
    Beauchamp, Guy
    Janvier, Valentin
    Laverty, Sheila
    EQUINE VETERINARY JOURNAL, 2025, 57 (01) : 203 - 216
  • [32] Structure-function of cartilage in osteoarthritis: An ex-vivo correlation analysis between its structural, viscoelastic and frictional properties
    de Roy, Luisa
    Teixeira, Graciosa Quelhas
    Schwer, Jonas
    Sukopp, Matthias
    Faschingbauer, Martin
    Ignatius, Anita
    Seitz, Andreas Martin
    ACTA BIOMATERIALIA, 2024, 190 : 293 - 302
  • [33] Cationic contrast-enhanced computed tomography distinguishes between reparative, degenerative, and healthy equine articular cartilage
    Nelson, Brad B.
    Makela, Janne T. A.
    Lawson, Taylor B.
    Patwa, Amit N.
    Snyder, Brian D.
    McIlwraith, C. Wayne
    Grinstaff, Mark W.
    Goodrich, Laurie R.
    Kawcak, Chris E.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2021, 39 (08) : 1647 - 1657
  • [34] COMPARISONS AMONG RADIOGRAPHY, ULTRASONOGRAPHY AND COMPUTED TOMOGRAPHY FOR EX VIVO CHARACTERIZATION OF STIFLE OSTEOARTHRITIS IN THE HORSE
    De Lasalle, Julie
    Alexander, Kate
    Olive, Julien
    Laverty, Sheila
    VETERINARY RADIOLOGY & ULTRASOUND, 2016, 57 (05) : 489 - 501
  • [35] Ex vivo magnetic resonance imaging of the distal row of equine carpal bones:: Assessment of bone sclerosis and cartilage damage
    Anastasiou, A
    Skioldebrand, E
    Ekman, S
    Hall, LD
    VETERINARY RADIOLOGY & ULTRASOUND, 2003, 44 (05) : 501 - 512
  • [36] Quantified Coronary Frequency Domain Optical Coherence Tomography Signal Analysis for the Evaluation of Erythrocyte-Rich Thrombus: ex-vivo Validation Study
    Shiratori, Yoshitaka
    Watanabe, Masato
    Suzuki, Nobuaki
    Naito, Kazuya
    Maeno, Yoshio
    Yamamoto, Hirosada
    Ishikawa, Shuichi
    Kyono, Hiroyuki
    Kondo, Fukuo
    Fukusato, Toshio
    Kozuma, Ken
    Isshiki, Takaaki
    CIRCULATION, 2013, 128 (22)
  • [37] Quantified coronary frequency domain optical coherence tomography signal analysis for the evaluation of erythrocyte-rich thrombus: ex-vivo validation study
    Shiratori, Yoshitaka
    Watanabe, Masato
    Suzuki, Nobuaki
    Fukusato, Toshio
    Kozuma, Ken
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (05) : 587 - 594
  • [38] Root Canal Morphology and Configuration of 118 Mandibular First Molars by Means of Micro-Computed Tomography: An Ex Vivo Study
    Wolf, Thomas Gerhard
    Paque, Frank
    Zeller, Maximilian
    Willershausen, Brita
    Briseno-Marroquin, Benjamin
    JOURNAL OF ENDODONTICS, 2016, 42 (04) : 610 - 614
  • [39] Location-Dependent Human Osteoarthritis Cartilage Response to Realistic Cyclic Loading: Ex-Vivo Analysis on Different Knee Compartments
    Assirelli, Elisa
    Caravaggi, Paolo
    Mazzotti, Antonio
    Ursini, Francesco
    Leardini, Alberto
    Belvedere, Claudio
    Neri, Simona
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [40] Quantified coronary frequency domain optical coherence tomography signal analysis for the evaluation of erythrocyte-rich thrombus: ex-vivo validation study
    Yoshitaka Shiratori
    Masato Watanabe
    Nobuaki Suzuki
    Toshio Fukusato
    Ken Kozuma
    The International Journal of Cardiovascular Imaging, 2017, 33 : 587 - 594