Monte Carlo calculated beam quality correction factors for high energy photon and electron fields

被引:0
|
作者
Czarnecki, Damian [1 ]
Zink, Klemens [1 ,2 ]
机构
[1] Univ Appl Sci THM, Inst Med Phys & Radiat Protect, Wiesenstr 14, D-35390 Giessen, Germany
[2] Marburg Univ Hosp, Dept Radiotherapy & Radiooncol, D-35043 Marburg, Germany
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2025年 / 131卷
关键词
Dosimetry; Beam quality correction factor; Ionization chamber; Monte carlo simulation; REFERENCE DOSIMETRY;
D O I
10.1016/j.ejmp.2025.104939
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Although several studies provide data on reference dosimetry, ionization chambers are in clinical use worldwide, for which no or only a few correction factors for beam quality are available. The aim of this study was to calculate beam quality correction factors in electron and photon fields for four cylindrical ionization chamber, i.e. CC08, CC04, Razor T Chamber and Razor T Nano Chamber (all IBA, Dosimetry, Schwarzenbruck, Germany). Method: Monte Carlo simulations were performed with the EGSnrc code system to calculate the beam quality correction factor k(Q). Therefore, a detailed Monte Carlo based model of the four ionization chambers were created to calculate the dose in the sensitive volume. Electron and photon spectra of clinical linear accelerators within the entire energy range of therapeutic linear accelerators were used as radiation source. Results: k(Q) values as a function of the beam quality specifiers TPR20,10 and R-50 were calculated for high energy photon and electron fields, respectively. The data was fitted against recommended equations for photon and electron dosimetry with a chi(2) between 6.4e-7 and 4.2e-6. Conclusion: Electron and photon beam quality correction factors k(Q) were calculated by Monte Carlo simulations for the cylindrical ionization chambers CC08, CC04, Razor (TM) Chamber and Razor (TM) Nano Chamber to provide k(Q) values for absolute dosimetry according to the TRS 398 dosimetry protocol.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Comparison of doses calculated by the Monte Carlo method and measured by Lif TLD in the buildup region for a 60Co photon beam
    Budanec, M.
    Knezevic, Z.
    Bokulic, T.
    Mrcela, I.
    Vrtar, M.
    Vekic, B.
    Kusic, Z.
    APPLIED RADIATION AND ISOTOPES, 2008, 66 (12) : 1925 - 1929
  • [42] Small fields characterization of teletherapy cobalt-60 photon beam: An experimental and Monte-Carlo study
    Singh A.
    Singh G.
    Saini A.
    Kinhikar R.A.
    Kumar P.
    Measurement: Sensors, 2023, 25
  • [43] Estimation of inhomogenity correction factors for a Co-60 beam using Monte Carlo simulation
    Praveenkumar, R. D.
    Santhosh, K. P.
    Augustine, A.
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2011, 7 (03) : 308 - 313
  • [44] Monte Carlo simulation of projection electron beam lithography
    Sun, X.
    Xiao, P.
    Ding, Z. J.
    NANOSCIENCE AND TECHNOLOGY, PTS 1 AND 2, 2007, 121-123 : 1097 - 1101
  • [45] A Monte Carlo approach for small electron beam dosimetry
    Rincón, M
    Sánchez-Doblado, F
    Perucha, M
    Leal, A
    Arráns, R
    Carrasco, E
    Sánchez-Calzado, JA
    Errazquin, L
    RADIOTHERAPY AND ONCOLOGY, 2001, 58 (02) : 179 - 185
  • [46] A Monte-Carlo simulation of the equilibrium beam polarization in ultra-high energy electron (positron) storage rings
    Duan, Zhe
    Bai, Mei
    Barber, Desmond P.
    Qin, Qing
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 793 : 81 - 91
  • [47] Dosimetric variation due to the photon beam energy in the small-animal irradiation: A Monte Carlo study
    Chow, James C. L.
    Leung, Michael K. K.
    Lindsay, Patricia E.
    Jaffray, David A.
    MEDICAL PHYSICS, 2010, 37 (10) : 5322 - 5329
  • [48] MONTE CARLO SIMULATIONS OF THE PHOTON CALIBRATION FIELDS AT THE UNDERGROUND LABORATORY OF PTB
    Kowatari, M.
    Dombrowski, H.
    Neumaier, S.
    RADIATION PROTECTION DOSIMETRY, 2010, 142 (2-4) : 125 - 135
  • [49] Monte Carlo Simulation of Electron Trajectory in Solid for Electron Beam Lithography
    Nagao, Akie
    Hosaka, Sumio
    ADVANCED MICRO-DEVICE ENGINEERING IV, 2014, 596 : 101 - 106
  • [50] Benchmark test of Monte-Carlo simulation for high resolution electron beam lithography
    Rommel, Marcus
    Hoffmann, Karl E.
    Reindl, Thomas
    Weis, Juergen
    Unal, Nezih
    Hofmann, Ulrich
    MICROELECTRONIC ENGINEERING, 2012, 98 : 202 - 205