Monte Carlo calculated beam quality correction factors for high energy photon and electron fields

被引:0
|
作者
Czarnecki, Damian [1 ]
Zink, Klemens [1 ,2 ]
机构
[1] Univ Appl Sci THM, Inst Med Phys & Radiat Protect, Wiesenstr 14, D-35390 Giessen, Germany
[2] Marburg Univ Hosp, Dept Radiotherapy & Radiooncol, D-35043 Marburg, Germany
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2025年 / 131卷
关键词
Dosimetry; Beam quality correction factor; Ionization chamber; Monte carlo simulation; REFERENCE DOSIMETRY;
D O I
10.1016/j.ejmp.2025.104939
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Although several studies provide data on reference dosimetry, ionization chambers are in clinical use worldwide, for which no or only a few correction factors for beam quality are available. The aim of this study was to calculate beam quality correction factors in electron and photon fields for four cylindrical ionization chamber, i.e. CC08, CC04, Razor T Chamber and Razor T Nano Chamber (all IBA, Dosimetry, Schwarzenbruck, Germany). Method: Monte Carlo simulations were performed with the EGSnrc code system to calculate the beam quality correction factor k(Q). Therefore, a detailed Monte Carlo based model of the four ionization chambers were created to calculate the dose in the sensitive volume. Electron and photon spectra of clinical linear accelerators within the entire energy range of therapeutic linear accelerators were used as radiation source. Results: k(Q) values as a function of the beam quality specifiers TPR20,10 and R-50 were calculated for high energy photon and electron fields, respectively. The data was fitted against recommended equations for photon and electron dosimetry with a chi(2) between 6.4e-7 and 4.2e-6. Conclusion: Electron and photon beam quality correction factors k(Q) were calculated by Monte Carlo simulations for the cylindrical ionization chambers CC08, CC04, Razor (TM) Chamber and Razor (TM) Nano Chamber to provide k(Q) values for absolute dosimetry according to the TRS 398 dosimetry protocol.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Determination of the beam quality correction factor for the microLion chamber in a clinical photon beam
    Choi, Sang Hyoun
    Kim, Chan Hyeong
    Do Huh, Hyun
    Kim, Kum-Bae
    Kim, SeongHoon
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2013, 62 (01) : 152 - 158
  • [22] Monte Carlo calculation of beam quality correction factors in proton beams using TOPAS/GEANT4
    Baumann, Kilian-Simon
    Kaupa, Sina
    Bach, Constantin
    Engenhart-Cabillic, Rita
    Zink, Klemens
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (05)
  • [23] Comparison of skin dose calculated by the dose tracking system (DTS) with a beam angular correction factor and that calculated by Monte-Carlo
    Sun, Sheng-Hsuan
    Rudin, Stephen
    Bednarek, Daniel R.
    MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING, 2021, 11595
  • [24] Calculation of beam quality correction factors for various thimble ionization chambers using the Monte Carlo code PENELOPE
    Erazo, Fabian
    Lallena, Antonio M.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2013, 29 (02): : 163 - 170
  • [25] Dose discrepancies between Monte Carlo calculations and measurements in the buildup region for a high-energy photon beam
    Ding, GX
    MEDICAL PHYSICS, 2002, 29 (11) : 2459 - 2463
  • [26] Sensitive volume effects on Monte Carlo calculated ion chamber response in magnetic fields
    Malkov, Victor N.
    Rogers, D. W. O.
    MEDICAL PHYSICS, 2017, 44 (09) : 4854 - 4858
  • [27] Monte Carlo calculation of beam quality correction for solid-state detectors and phantom scatter correction at 137Cs energy
    Selvam, T. Palani
    Mishra, Subhalaxmi
    Vishwakarma, R. S.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (01): : 339 - 350
  • [28] Beam quality correction factors for ionization chambers in a 0.35 T magnetic resonance (MR)-linac - A Monte Carlo study
    Khan, Ahtesham Ullah
    DeWerd, Larry A.
    Yadav, Poonam
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 119
  • [29] GEANT4-based Monte Carlo Simulation of Beam Quality Correction Factors for the Leksell Gamma Knife® Perfexion™
    Thomas Schaarschmidt
    Tae Hoon Kim
    Yong Kyun Kim
    Hye Jeong Yang
    Hyun-Tai Chung
    Journal of the Korean Physical Society, 2018, 73 : 1814 - 1820
  • [30] A study of the beam quality correction factor in clinical proton beam conditions using Monte Carlo simulations
    Kwon, Yong-Cheol
    Pak, Sang-Il
    Jo, Hyon-Suk
    Jeong, Seonghoon
    Lee, Se Byeong
    Kim, In Jung
    Yi, Chul-Young
    Shin, Wook-Geun
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2022, 81 (11) : 1128 - 1134