摘要
Background: Percutaneous pedicle screw (PPS) placement has become a pivotal technique in spinal surgery, increasing surgical efficiency and limiting the invasiveness of surgical procedures. The aim of this study was to analyze the accuracy of computer- assisted PPS placement with a standardized technique in the lateral decubitus position. Methods: A retrospective review of prospectively collected data was performed on 44 consecutive patients treated between 2021 and 2023 with lateral decubitus single- position surgery. PPS placement was assessed by computed tomography scans, and breaches were graded based on the magnitude and direction of the breach. Facet joint violations were assessed. Variables collected included patient demographics, indication, intraoperative complications, operative time, fluoroscopy time, estimated blood loss, and length of stay. Results: Forty- four patients, with 220 PPSs were identified. About 79.5% of all patients underwent anterior lumbar interbody fusion only, 13.6% underwent lateral lumbar interbody fusion only, and 6.8% received a combination of both anterior lumbar interbody fusion and lateral lumbar interbody fusion. Eleven screw breaches (5%) were identified: 10 were Grade II breaches (<2 mm), and 1 was a Grade IV breach (>4 mm). All breaches were lateral. About 63.6% involved down- side screws indicating a trend toward the laterality of breaches for down- side pedicles. When analyzing breaches by level, 1.2% of screws at L5, 13% at L4, and 11.1% at L3 demonstrated Grade II breaches. No facet joint violations were noted. Conclusion: PPS placement utilizing computer- assisted navigation in lateral decubitus single- position surgery is both safe and accurate. An overall breach rate of 5% was found; considering a safe zone of 2 mm, only 1 screw (0.5%) demonstrated a relevant breach. Clinical Relevance:PPS placement is both safe and accurate. Breaches are rare, and when breaches do occur, they are lateral. Level of Evidence: 3.
引用
收藏
页码:365 / 374
页数:11
相关论文
共 26 条
[1]   Methods to determine pedicle screw placement accuracy in spine surgery: a systematic review [J].
Aoude, Ahmed A. ;
Fortin, Maryse ;
Figueiredo, Rainer ;
Jarzem, Peter ;
Ouellet, Jean ;
Weber, Michael H. .
EUROPEAN SPINE JOURNAL, 2015, 24 (05) :990-1004
[2]   Single position lateral decubitus anterior lumbar interbody fusion (ALIF) and posterior fusion reduces complications and improves perioperative outcomes compared with traditional anterior-posterior lumbar fusion [J].
Ashayeri, Kimberly ;
Leon, Carlos ;
Tigchelaar, Seth ;
Fatemi, Parastou ;
Follett, Matt ;
Cheng, Ivan ;
Thomas, J. Alex ;
Medley, Mark ;
Braly, Brett ;
Kwon, Brian ;
Eisen, Leon ;
Protopsaltis, Themistocles S. ;
Buckland, Aaron J. .
SPINE JOURNAL, 2022, 22 (03) :419-428
[3]   MIS Single-position Lateral and Oblique Lateral Lumbar Interbody Fusion and Bilateral Pedicle Screw Fixation Feasibility and Perioperative Results [J].
Blizzard, Daniel J. ;
Thomas, J. Alex .
SPINE, 2018, 43 (06) :440-446
[4]   Lateral decubitus single position anterior posterior surgery improves operative efficiency, improves perioperative outcomes, and maintains radiological outcomes comparable with traditional anterior posterior fusion at minimum 2-year follow-up [J].
Buckland, Aaron J. ;
Braly, Brett A. ;
O'Malley, Nicholas A. ;
Ashayeri, Kimberly ;
Protopsaltis, Themistocles S. ;
Kwon, Brian ;
Cheng, Ivan ;
Thomas, J. Alex .
SPINE JOURNAL, 2023, 23 (05) :685-694
[5]   Single position circumferential fusion improves operative efficiency, reduces complications and length of stay compared with traditional circumferential fusion [J].
Buckland, Aaron J. ;
Ashayeri, Kimberly ;
Leon, Carlos ;
Manning, Jordan ;
Eisen, Leon ;
Medley, Mark ;
Protopsaltis, Themistocles S. ;
Thomas, J. Alex .
SPINE JOURNAL, 2021, 21 (05) :810-820
[6]   CT accuracy of percutaneous versus open pedicle screw techniques: a series of 1609 screws [J].
Chapman, Todd M. ;
Blizzard, Daniel J. ;
Brown, Christopher R. .
EUROPEAN SPINE JOURNAL, 2016, 25 (06) :1781-1786
[7]   Template guided cervical pedicle screw instrumentation [J].
Farshad, Mazda ;
Spirig, Jose Miguel ;
Winkler, Elin ;
Suter, Daniel ;
Farshad-Amacker, Nadja ;
Jarvers, Jan-Sven ;
Tschoeke, Sven Kevin ;
Heyde, Christoph-Eckhard ;
Calek, Anna-Katharina .
NORTH AMERICAN SPINE SOCIETY JOURNAL, 2022, 10
[8]   Percutaneous Pedicle Screw Placement in the Lumbar Spine A Comparison Study Between the Novel Guidance System and the Conventional Fluoroscopy Method [J].
Gu, Guangfei ;
Zhang, Hailong ;
He, Shisheng ;
Cai, Xiaobing ;
Gu, Xin ;
Jia, Jianbo ;
Fu, Qingsong ;
Zhou, Xu .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2015, 28 (09) :E522-E527
[9]   Assessing Procedural Accuracy in Lateral Spine Surgery: A Retrospective Analysis of Percutaneous Pedicle Screw Placement with Intraoperative CT Navigation [J].
Hiyama, Akihiko ;
Sakai, Daisuke ;
Katoh, Hiroyuki ;
Nomura, Satoshi ;
Watanabe, Masahiko .
JOURNAL OF CLINICAL MEDICINE, 2023, 12 (21)
[10]   Accuracy of pedicle screw insertion in the thoracic and lumbar spine: a comparative study between percutaneous screw insertion and conventional open technique [J].
Ikeuchi, Hiroko ;
Ikuta, Ko .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2016, 136 (09) :1195-1202