Evaluation of the Effectiveness of Continuous Glucose Monitors on Glycemic Control in Patients With Type 2 Diabetes Receiving Institutional Financial Assistance

被引:0
作者
Cheng, Kevin K. [1 ]
Cruz, Maxine F. Vera [2 ]
Tylee, Tracy S. [3 ]
Kelly, Mary S. [4 ]
机构
[1] Univ Washington Med, Dept Pharm, 1959 NE Pacific St, Box 356015, Seattle, WA 98195 USA
[2] Univ Washington, Sch Med, Seattle, WA USA
[3] Univ Washington Med, Dept Med, Div Endocrinol, Seattle, WA USA
[4] Univ Washington Med, Harborview Med Ctr, Dept Pharm, Seattle, WA USA
关键词
blood glucose; continuous glucose monitoring; diabetes mellitus; type; 2; financial assistance; hemoglobin A(1c); REAL-TIME;
D O I
10.1177/19322968251320122
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Current guidelines suggest utilizing continuous glucose monitoring (CGM) to improve hemoglobin A1c (HbA1c) in patients with diabetes. Financial cost remains a barrier to implementation. Medicare coverage criteria include all patients with diabetes treated with at least one injection of insulin per day, while Washington Medicaid is more restrictive. There remains a paucity of literature examining effectiveness of CGMs on clinical outcomes among patients with type 2 diabetes with lower incomes. Methods: This is a single-center, retrospective, observational study including adults with type 2 diabetes receiving institutional financial assistance for CGMs. A cohort with no CGM use is included for comparison. The primary outcome is change in HbA1c approximately three months after CGM implementation from baseline. Secondary outcomes include mean differences in number of antidiabetic agents and changes in insulin dose prior to and after CGM implementation. Results: Among the CGM cohort, most patients were of Hispanic ethnicity (77%) and a majority had no insurance (77%). The average HbA1c prior to CGM implementation was 8.3% and three months post-CGM was 7.7%, with a mean difference of -0.6% (P = .004). There were no statistically significant differences in the average number of antidiabetic agents, total daily dosages of insulin, or mean differences in the number of emergency room visits or hospitalizations prior to and post-implementation of a CGM. Conclusion: Overall, there is a statistical and clinical improvement in HbA1c before and after implementation of CGMs in patients with type 2 diabetes who meet Medicaid criteria for CGM coverage receiving financial assistance.
引用
收藏
页数:7
相关论文
共 25 条
[1]  
[Anonymous], 1993, NEW ENGL J MED, V329, P977, DOI [10.1056/NEJM199309303291401, DOI 10.1056/NEJM199309303291401]
[2]   Continuous Glucose Monitoring Versus Usual Care in Patients With Type 2 Diabetes Receiving Multiple Daily Insulin Injections A Randomized Trial [J].
Beck, Roy W. ;
Riddlesworth, Tonya D. ;
Ruedy, Katrina ;
Ahmann, Andrew ;
Haller, Stacie ;
Kruger, Davida ;
McGill, Janet B. ;
Polonsky, William ;
Price, David ;
Aronoff, Stephen ;
Aronson, Ronnie ;
Toschi, Elena ;
Kollman, Craig ;
Bergenstal, Richard .
ANNALS OF INTERNAL MEDICINE, 2017, 167 (06) :365-+
[3]  
Centers for Disease Control and Prevention (Diabetes), 2024, National diabetes statistics report
[4]  
Centers for Medicare & Medicaid Services (CMS), 2023, Glucose monitors
[5]   Comparative efficacy and safety of glucagon-like peptide 1 receptor agonists for the treatment of type 2 diabetes: A network meta-analysis [J].
Chen, Han ;
Li, Xin-Zhu ;
Chen, Jia-Qing ;
Ren, Tian-Shu ;
Zhang, Ying-Shi ;
Wang, Yi-Nuo ;
Zhao, Qing-Chun .
MEDICINE, 2023, 102 (27) :E34122
[6]   Patient Demographics and Clinical Outcomes Among Type 1 Diabetes Patients Using Continuous Glucose Monitors: Data From T1D Exchange Real-World Observational Study [J].
DeSalvo, Daniel J. ;
Noor, Nudrat ;
Xie, Cicilyn ;
Corathers, Sarah D. ;
Majidi, Shideh ;
McDonough, Ryan J. ;
Polsky, Sarit ;
Izquierdo, Roberto ;
Rioles, Nicole ;
Weinstock, Ruth ;
Obrynba, Kathryn ;
Roberts, Alissa ;
Vendrame, Francesco ;
Sanchez, Janine ;
Ebekozien, Osagie .
JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2023, 17 (02) :322-328
[7]   Clinical Implications of Real-time and Intermittently Scanned Continuous Glucose Monitoring [J].
Edelman, Steven V. ;
Argento, Nicholas B. ;
Pettus, Jeremy ;
Hirsch, Irl B. .
DIABETES CARE, 2018, 41 (11) :2265-2274
[8]  
Ehrhardt Nicole M, 2011, J Diabetes Sci Technol, V5, P668
[9]   Diabetes Technology: Standards of Care in Diabetes-2023 [J].
ElSayed, Nuha A. ;
Aleppo, Grazia ;
Aroda, Vanita R. ;
Bannuru, Raveendhara R. ;
Brown, Florence M. ;
Bruemmer, Dennis ;
Collins, Billy S. ;
Hilliard, Marisa E. ;
Isaacs, Diana ;
Johnson, Eric L. ;
Kahan, Scott ;
Khunti, Kamlesh ;
Leon, Jose ;
Lyons, Sarah K. ;
Perry, Mary Lou ;
Prahalad, Priya ;
Pratley, Richard E. ;
Seley, Jane Jeffrie ;
Stanton, Robert C. ;
Gabbay, Robert A. .
DIABETES CARE, 2023, 46 :S111-S127
[10]   Demonstrating the Clinical Impact of Continuous Glucose Monitoring Within an Integrated Healthcare Delivery System [J].
Isaacson, Brad ;
Kaufusi, Stephanie ;
Sorensen, Jeff ;
Joy, Elizabeth ;
Jones, Christopher ;
Ingram, Valerie ;
Mark, Nickolas ;
Phillips, Mike ;
Briesacher, Mark .
JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2022, 16 (02) :383-389