LC-ESI-MS/MS method for the accurate quantification of eight nitrosamines in pharmaceutical products

被引:0
作者
Danis, Ibrahim [1 ,2 ,3 ]
Unal, Durisehvar Ozer [1 ,2 ]
机构
[1] Istanbul Univ, Fac Pharm, Dept Analyt Chem, Istanbul, Turkiye
[2] Istanbul Univ, Drug Res Ctr, TR-34116 Istanbul, Turkiye
[3] Istanbul Univ, Inst Hlth Sci, Istanbul, Turkiye
关键词
Nitrosamine; impurity; pharmaceutical products; chromatography; mass spectrometry; IMPURITIES; ISTANBUL;
D O I
10.1177/14690667251328823
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
In 2018, the Food and Drug Administration and the European Medicines Agency identified nitrosamine impurities in certain drugs, prompting detailed investigations by international regulatory authorities. According to ICH M7 (R1) guidelines, nitrosamines are classified as Class 1 substances, the most hazardous category, based on their carcinogenic and mutagenic properties. They are also recognized as probable human carcinogens by the International Agency for Research on Cancer. Since nitrosamine-induced DNA damage poses significant health risks, identifying potential nitrosamines in pharmaceutical products is crucial. In this study, a simple and efficient extraction method was designed to minimize matrix effects. These effects were evaluated using calibration curves prepared for each drug product in their respective matrices. The developed method was performed using an Agilent 1260 series HPLC system and an Agilent 6460 triple quadrupole tandem mass spectrometer. An Inertsil ODS-3 C18 (5 mu m, 4.6 x 150 mm) column was employed for chromatographic separation. A triple quadrupole mass detector with electrospray ionization was used for detection, and multiple reaction monitoring was employed for quantification. The correlation coefficients (r(2)) were at least 0.999 for all eight nitrosamines. Limit of detection and limit of quantification values were determined as 0.05-0.8 ng/mL and 0.1-2.0 ng/mL, respectively. Validation results demonstrated satisfactory selectivity, accuracy, precision, and stability. The results demonstrated that the developed method is capable of reliably detecting potential nitrosamines present in pharmaceutical products at trace levels. This method contributes significantly to pharmaceutical safety and can serve as a valuable tool for future analyses.
引用
收藏
页数:12
相关论文
共 51 条
  • [1] Cost-effective, green HPLC determination of losartan, valsartan and their nitrosodiethylamine impurity: application to pharmaceutical dosage forms
    Abd El-Hay, Soad S.
    Elhenawee, Magda
    Maged, Khaled
    Ibrahim, Adel Ehab
    [J]. ROYAL SOCIETY OPEN SCIENCE, 2022, 9 (06):
  • [2] A novel fast analytical method for the determination of N-nitroso vonoprazan in vonoprazan tablets and raw materials using LC-ESI-MS/MS
    Abuothman, Mohammad
    Deeb, Ahmad A.
    Hailat, Mohammad
    Abuyaman, Omar
    Aldoqum, Hani M.
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2024,
  • [3] Development and validation of high-performance liquid chromatography-Orbitrap mass spectrometric method for quantification of NDMA in ranitidine drug products and evaluation of antioxidants as inhibitors of classical nitrosation reaction
    Aishwarya, Dande
    Nikhil, Pallaprolu
    Natesan, Subramanian
    Velayutham, Ravichandiran
    Peraman, Ramalingam
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2024, 38 (11)
  • [4] The ECHO technique -: the more effective way of data evaluation in liquid chromatography-tandem mass spectrometry analysis
    Alder, L
    Lüderitz, S
    Lindtner, K
    Stan, HJ
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2004, 1058 (1-2) : 67 - 79
  • [5] [Anonymous], 2020, Nitrosamine impurities in human medicinal products
  • [6] A Critical N-Nitrosamine Impurity of Anticoagulant Drug, Rivaroxaban: Synthesis, Characterization, Development of LC-MS/MS Method for Nanogram Level Quantification
    Baksam, Vijaya Kumar
    Saritha, Nimmakayala
    Devineni, Subba Rao
    Jain, Mohit
    Kumar, Prashanth
    Shandilya, Sanjeev
    Kumar, Pramod
    [J]. CHROMATOGRAPHIA, 2022, 85 (01) : 73 - 82
  • [7] BARNES JM, 1954, BRIT J IND MED, V11, P167
  • [8] Development and Validation of a Method for the Semi-Quantitative Determination of N-Nitrosamines in Active Pharmaceutical Ingredient Enalapril Maleate by Means of Derivatisation and Detection by HPLC with Fluorimetric Detector
    Boczar, Dariusz
    Wyszomirska, Elzbieta
    Zabrzewska, Beata
    Chyla, Anna
    Michalska, Katarzyna
    [J]. APPLIED SCIENCES-BASEL, 2021, 11 (16):
  • [9] Cancer IAfRo, 2012, Agents classified by the IARC monographs, V1-106
  • [10] Development of a sensitive LC-MS/MS method for simultaneous determination of three nitrosamines in losartan API and assessment of nitrosamines formation
    Carlos, Graciela
    Martini, Paulo R. R.
    Machioli, Lilian F.
    Garcia, Cassia, V
    Paim, Clesio S.
    de Oliveira, Tiago Franco
    Mendez, Andreas S. L.
    [J]. MICROCHEMICAL JOURNAL, 2025, 208