Correlation-Based Approach for Heart Rate Extraction Using UWB Impulse Radar

被引:0
|
作者
Le, Dang-Khanh [1 ]
机构
[1] Vietnam Maritime Univ, Dept Marine Engn, Hai Phong City, Vietnam
关键词
UWB radar; Remote vital signs measurement; Maritime safety; Chirp-Z correlation;
D O I
10.5391/IJFIS.2025.25.1.55
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
Ultra-wideband (UWB) radar technology has emerged as a significant tool in maritime applications due to its unique capabilities in high-resolution imaging, target detection, obstacle penetration, and vital signs monitoring. Unlike traditional radar systems, UWB radar offers unique advantages, including higher performance in complex environments, making it suitable for various maritime scenarios. These include vessel tracking, search and rescue operations, underwater exploration, and, especially, crew health situation monitoring. UWB impulse radar, in particular, is gaining significant attention for its ability to conduct contactless vital sign monitoring, particularly for measuring respiration and heart rate through thoracic motion. However, heartbeat signals are typically low in intensity and prone to interference from noise and non-stationary signals. This paper proposes a novel correlation-based approach designed to enhance the signal-to-noise ratio (SNR) and improve the accuracy of heart rate extraction. The approach employs the chirp Z-transform for higher frequency resolution, combined with a sliding window-based cross-correlation method to isolate and amplify vital signals in the frequency domain. Experimental results demonstrate that the proposed method significantly improves SNR, achieving a 30 dB increase in respiration and a 10 dB increase in heart rate compared to traditional methods. Furthermore, the approach reduces heart rate error to just 0.003 Hz, showcasing its potential for reliable vital sign monitoring. Future work will focus on exploring larger datasets and expanding this method for behind-wall detection applications.
引用
收藏
页码:55 / 62
页数:8
相关论文
共 50 条
  • [1] Heart rate extraction based on eigenvalues using UWB impulse radar remote sensing
    Minhhuy Le
    SENSORS AND ACTUATORS A-PHYSICAL, 2020, 303
  • [2] Multivariate Correlation of Higher Harmonics for Heart Rate Remote Measurement Using UWB Impulse Radar
    Minhhuy Le
    Binh Van Nguyen
    IEEE SENSORS JOURNAL, 2020, 20 (04) : 1859 - 1866
  • [3] Robust Heart Rate Detection Method using UWB Impulse Radar
    Cho, Hui-Sup
    Park, Young-Jin
    Lyu, Hong-Kun
    2016 INTERNATIONAL CONFERENCE ON INFORMATION AND COMMUNICATION TECHNOLOGY CONVERGENCE (ICTC 2016): TOWARDS SMARTER HYPER-CONNECTED WORLD, 2016, : 1138 - 1142
  • [4] Novel Heart Rate Detection Method Using UWB Impulse Radar
    Hui-Sup Cho
    Young-Jin Park
    Hong-Kun Lyu
    Jin-Ho Cho
    Journal of Signal Processing Systems, 2017, 87 : 229 - 239
  • [5] Novel Heart Rate Detection Method Using UWB Impulse Radar
    Cho, Hui-Sup
    Park, Young-Jin
    Lyu, Hong-Kun
    Cho, Jin-Ho
    JOURNAL OF SIGNAL PROCESSING SYSTEMS FOR SIGNAL IMAGE AND VIDEO TECHNOLOGY, 2017, 87 (02): : 229 - 239
  • [6] Detection of Heart Rate through a Wall Using UWB Impulse Radar
    Cho, Hui-Sup
    Park, Young-Jin
    JOURNAL OF HEALTHCARE ENGINEERING, 2018, 2018
  • [7] Correlation-Based UWB Radar for Thin Layer Resolution
    Taheri, Omid
    Maunder, Adam
    Mousavi, Pedram
    IEEE ANTENNAS AND WIRELESS PROPAGATION LETTERS, 2016, 15 : 901 - 904
  • [8] Phase-Based Methods for Heart Rate Detection Using UWB Impulse Doppler Radar
    Ren, Lingyun
    Wang, Haofei
    Naishadham, Krishna
    Kilic, Ozlem
    Fathy, Aly E.
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2016, 64 (10) : 3319 - 3331
  • [9] Noncontact Heartbeat Extraction Using UWB Impulse Radar
    Jing, Fangfei
    Tian, Xiaoqing
    Liang, Jing
    COMMUNICATIONS, SIGNAL PROCESSING, AND SYSTEMS, VOL. 1, 2022, 878 : 472 - 479
  • [10] Random Correlation-Based Receiver for Impulse Radio Communications in UWB Channels
    Qi Zhang
    Jiayin Qin
    Wireless Personal Communications, 2014, 79 : 21 - 30