Meta-Analysis of Pulsed-Field Ablation Versus- High-Power Short-Duration Ablation for Atrial Fibrillation

被引:0
作者
Xue, Jun [1 ]
Huang, Qunying [2 ]
Yu, Fuling [2 ]
Mao, Yinjun [3 ,4 ]
机构
[1] First Hosp Putian City, Dept Pharm, Putian, Peoples R China
[2] Fujian Med Univ, Affiliated Hosp 1, Dept Cardiol, Fuzhou, Peoples R China
[3] Fujian Med Univ, Affiliated Hosp 1, Dept Pharm, Fuzhou, Peoples R China
[4] Fujian Med Univ, Affiliated Hosp 1, Natl Reg Med Ctr, Dept Pharm, Binhai Campus, Fuzhou, Peoples R China
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2025年 / 48卷 / 02期
关键词
atrial fibrillation; high-power short-duration ablation; meta-analysis; procedural efficiency; pulsed-field ablation; PULMONARY VEIN ISOLATION; RADIOFREQUENCY ABLATION; SAFETY; CRYOBALLOON; OUTCOMES; LESIONS; TIP;
D O I
10.1111/pace.15141
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
PurposeTo optimize the effectiveness and safety of pulmonary vein isolation, pulsed-field ablation (PFA) and high-power short-duration ablation (HPSD) have recently been incorporated into clinical practice. The objective of this study is to conduct a comparative analysis, focusing on the efficacy, safety, and procedural efficiency of PFA and HPSD in the treatment of atrial fibrillation (AF).MethodsA thorough search was performed across multiple databases to identify trials that compared PFA with HPSD for AF from their inception until July 2024. The odds ratio (OR) and mean difference (MD), accompanied by a 95% confidence interval (CI), were employed as indicators of treatment efficacy.ResultsThe analysis included six eligible trials, encompassing a total enrollment of 1382 patients. No statistically significant disparities were observed in terms of freedom from any atrial arrhythmia (OR 1.10; 95% CI 0.75, 1.63) or periprocedural complications (OR 1.04; 95% CI 0.52, 2.09) between the two ablation techniques. The likelihood of requiring a repeat ablation procedure was significantly reduced with PFA compared to HPSD (OR 0.63; 95% CI 0.41-0.97); however, there was no significant difference in the incidence of PV reconnection between patients initially treated with HPSD and those using PFA (OR 0.83; 95% CI 0.53-1.30). The PFA technique demonstrated significantly shorter procedure time (MD -34.58; 95% CI -45.20, -23.96) and left atrium (LA) dwell time (MD -34.52; 95% CI -58.42, -10.61), but longer fluoroscopy time (MD 8.81; 95% CI 6.25, 11.37). The subgroup analyses revealed that PFA continued to exhibit superior procedure time and LA dwell time but inferior fluoroscopy time.ConclusionThe efficacy and safety profiles of both PFA and HPSD are comparable in patients undergoing ablation therapy for AF; however, PFA is associated with shorter procedural time and longer fluoroscopy time.
引用
收藏
页码:180 / 191
页数:12
相关论文
共 33 条
[11]   Bronchial Safety After Pulsed Field Ablation for Paroxysmal Atrial Fibrillation [J].
Fueting, Anna ;
Reinsch, Nico ;
Brokkaar, Lenny ;
Hartl, Stefan ;
Hoewel, Dennis ;
Essling, Anika ;
Bell, John ;
Rausch, Eva ;
Neven, Kars .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2023, 16 (04) :E011547
[12]   Quantifying heterogeneity in a meta-analysis [J].
Higgins, JPT ;
Thompson, SG .
STATISTICS IN MEDICINE, 2002, 21 (11) :1539-1558
[13]  
Hindricks G, 2021, EUR HEART J, V42, P546, DOI [10.1093/eurheartj/ehaa945, 10.1093/eurheartj/ehaa612]
[14]   Safety and outcome of very if high-power short-duration ablation using 70 W for pulmonary vein isolation in patients with paroxysmal atrial fibrillation [J].
Kottmaier, Marc ;
Popa, Miruna ;
Bourier, Felix ;
Reents, Tilko ;
Cifuentes, Jairo ;
Semmler, Verena ;
Telishevska, Martha ;
Otgonbayar, Ulamnemekh ;
Koch-Buettner, Katharina ;
Lennerz, Carsten ;
Bartkowiak, Marcin ;
Kornmayer, Marielouise ;
Rousseva, Elena ;
Brkic, Amir ;
Grebmer, Christian ;
Kolb, Christoph ;
Hessling, Gabriele ;
Deisenhofer, Isabel .
EUROPACE, 2020, 22 (03) :388-393
[15]   Cryoballoon or Radiofrequency Ablation for Paroxysmal Atrial Fibrillation [J].
Kuck, Karl-Heinz ;
Brugada, Josep ;
Fuernkranz, Alexander ;
Metzner, Andreas ;
Ouyang, Feifan ;
Chun, K. R. Julian ;
Elvan, Arif ;
Arentz, Thomas ;
Bestehorn, Kurt ;
Pocock, Stuart J. ;
Albenque, Jean-Paul ;
Tondo, Claudio .
NEW ENGLAND JOURNAL OF MEDICINE, 2016, 374 (23) :2235-2245
[16]   High-Power and Short-Duration Ablation for Pulmonary Vein Isolation Biophysical Characterization [J].
Leshem, Eran ;
Zilberman, Israel ;
Tschabrunn, Cory M. ;
Barkagan, Michael ;
Contreras-Valdes, Fernando M. ;
Govari, Assaf ;
Anter, Elad .
JACC-CLINICAL ELECTROPHYSIOLOGY, 2018, 4 (04) :467-479
[17]   Meta-analysis of high-power short-duration versus cryoballoon ablation for atrial fibrillation [J].
Lin, Limin ;
Huang, Ying ;
Huang, Qunying ;
Yu, Fuling ;
Mao, Yinjun .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2024, 47 (08) :1013-1024
[18]   Cell death due to electroporation - A review [J].
Napotnik, Tina Batista ;
Polajzer, Tamara ;
Miklavcic, Damijan .
BIOELECTROCHEMISTRY, 2021, 141 (141)
[19]   Myocardial injury and inflammation following pulsed-field ablation and very high-power short-duration ablation for atrial fibrillation [J].
Popa, Miruna A. ;
Bahlke, Fabian ;
Kottmaier, Marc ;
Foerschner, Leonie ;
Bourier, Felix ;
Lengauer, Sarah ;
Telishevska, Marta ;
Krafft, Hannah ;
Englert, Florian ;
Reents, Tilko ;
Lennerz, Carsten ;
Caluori, Guido ;
Jais, Pierre ;
Hessling, Gabriele ;
Deisenhofer, Isabel .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2024, 35 (02) :317-327
[20]   Results from a multicentre comparison of cryoballoon vs. radiofrequency ablation for paroxysmal atrial fibrillation: is cryoablation more reproducible? [J].
Providencia, Rui ;
Defaye, Pascal ;
Lambiase, Pier D. ;
Pavin, Dominique ;
Cebron, Jean-Pierre ;
Halimi, Franck ;
Anselme, Frederic ;
Srinivasan, Neil ;
Albenque, Jean-Paul ;
Boveda, Serge .
EUROPACE, 2017, 19 (01) :48-57