Scanning K-edge subtraction (SKES) imaging with laser-compton x-ray sources

被引:0
作者
Reutershan, Trevor [1 ,2 ]
Nguyen, Christine V. [1 ]
Effarah, Haytham H. [1 ,2 ]
Nelson, Eric C. [1 ]
Chesnut, Kyle D. [1 ]
Barty, Christopher P. J. [1 ,2 ,3 ]
机构
[1] Univ Calif Irvine, Dept Phys & Astron, Irvine, CA 92697 USA
[2] Univ Calif Irvine, Beckman Laser Inst & Med Clin, Irvine, CA USA
[3] Lumitron Technol Inc, Irvine, CA USA
基金
美国国家卫生研究院;
关键词
contrast-enhanced mammography; dual-energy; K-edge subtraction; laser-Compton; DIGITAL MAMMOGRAPHY; BREAST DENSITY; CONTRAST; GEANT4; SIMULATIONS; PERFORMANCE; RADIATION; DETECTOR; CT;
D O I
10.1002/mp.17638
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundK-edge subtraction (KES) imaging is a dual-energy imaging technique that enhances contrast by subtracting images taken with x-rays that are above and below the K-edge energy of a specified contrast agent. The resulting reconstruction spatially identifies where the contrast agent accumulates, even when obscured by complex and heterogeneous distributions of human tissue. This method is most successful when x-ray sources are quasimonoenergetic and tunable, conditions that have traditionally only been met at synchrotrons. Laser-Compton x-ray sources (LCSs) are a compact alternative to synchrotron radiation with a quasimonoenergetic x-ray spectrum. One limitation in the clinical application of KES imaging with LCSs has been the extensive time required to tune the x-ray spectrum to two different energies.PurposeWe introduce an imaging technique called scanning K-edge subtraction (SKES) that leverages the angle-correlated laser-Compton x-ray spectrum in the setting of mammography. The feasibility and utility of this technique will be evaluated through a series of simulation studies. The goal of SKES imaging is to enable rapid K-edge subtraction imaging using a laser-Compton x-ray source. The technique does not rely on the time-consuming process of tuning laser-Compton interaction parameters.MethodsLaser-Compton interaction physics are modeled using conditions based on an X-band linear electron accelerator architecture currently under development using a combination of 3D particle tracking software and Mathematica. The resulting angle-correlated laser-Compton x-ray beam is propagated through digitally compressed breast phantoms containing iodine contrast-enhanced inserts and then to a digital flat-panel detector using a Matlab Monte Carlo propagation software. This scanning acquisition technique is compared to the direct energy tuning method (DET), as well as to a clinically available dual-energy contrast-enhanced mammography (CEM) system.ResultsKES imaging in a scanning configuration using an LCS was able to generate a KES image of comparable quality to the direct energy tuning method. SKES was able to detect tumors with iodine contrast concentrations lower than what is clinically available today including lesions that are typically obscured by dense fibroglandular tissue. After normalizing to mean glandular dose, SKES is able to generate a KES image with equal contrast to CEM using only 3% of the dose.ConclusionsBy leveraging the unique quasimonochromatic and angle-correlated x-ray spectrum offered by LCSs, a contrast-enhanced subtraction image can be obtained with significantly more contrast and less dose compared to conventional systems, and improve tumor detection in patients with dense breast tissue. The scanning configuration of this technique could accelerate the clinical translation of this technology.
引用
收藏
页码:2475 / 2492
页数:18
相关论文
共 55 条
[1]   Characterization and applications of a tunable, laser-based, MeV-class Compton-scattering γ-ray source [J].
Albert, F. ;
Anderson, S. G. ;
Gibson, D. J. ;
Hagmann, C. A. ;
Johnson, M. S. ;
Messerly, M. ;
Semenov, V. ;
Shverdin, M. Y. ;
Rusnak, B. ;
Tremaine, A. M. ;
Hartemann, F. V. ;
Siders, C. W. ;
McNabb, D. P. ;
Barty, C. P. J. .
PHYSICAL REVIEW SPECIAL TOPICS-ACCELERATORS AND BEAMS, 2010, 13 (07)
[2]  
[Anonymous], 1989, Technical Report ICRU44.
[3]  
[Anonymous], 2023, Mammography Quality Standards Act
[4]  
Badano A, 2018, JAMA NETW OPEN, V1, DOI [10.1001/jamanetworkopen.2018.5474, 10.1007/s42001-018-0015-z]
[5]   Design, construction, and test of compact, distributed-charge, X-band accelerator systems that enable image-guided, VHEE FLASH radiotherapy [J].
Barty, Christopher P. J. ;
Algots, J. Martin ;
Amador, Alexander J. ;
Barty, James C. R. ;
Betts, Shawn M. ;
Castaneda, Marcelo A. ;
Chu, Matthew M. ;
Daley, Michael E. ;
Lopez, Ricardo A. De Luna ;
Diviak, Derek A. ;
Effarah, Haytham H. ;
Feliciano, Roberto ;
Garcia, Adan ;
Grabiel, Keith J. ;
Griffin, Alex S. ;
Hartemann, Frederic V. ;
Heid, Leslie ;
Hwang, Yoonwoo ;
Imeshev, Gennady ;
Jentschel, Michael ;
Johnson, Christopher A. ;
Kinosian, Kenneth W. ;
Lagzda, Agnese ;
Lochrie, Russell J. ;
May, Michael W. ;
Molina, Everardo ;
Nagel, Christopher L. ;
Nagel, Henry J. ;
Peirce, Kyle R. ;
Peirce, Zachary R. ;
Quinonez, Mauricio E. ;
Raksi, Ferenc ;
Ranganath, Kelanu ;
Reutershan, Trevor ;
Salazar, Jimmie ;
Schneider, Mitchell E. ;
Seggebruch, Michael W. L. ;
Yang, Joy Y. ;
Yeung, Nathan H. ;
Zapata, Collette B. ;
Zapata, Luis E. ;
Zepeda, Eric J. ;
Zhang, Jingyuan .
FRONTIERS IN PHYSICS, 2024, 12
[6]  
Barty CPJ., 2019, US Patent, Patent No. 10508998
[7]  
Barty CPJ., 2017, Modulated method for efficient, narrowbandwidth, laser Compton Xray and gammaray sources
[8]   Grid and slot scan scatter reduction in mammography: Comparison by using Monte Carlo techniques [J].
Boone, JM ;
Seibert, JA ;
Tang, CM ;
Lane, SM .
RADIOLOGY, 2002, 222 (02) :519-527
[9]   Validation of GEANT4, an object-oriented Monte Carlo toolkit, for simulations in medical physics [J].
Carrier, JF ;
Archambault, L ;
Beaulieu, L ;
Roy, R .
MEDICAL PHYSICS, 2004, 31 (03) :484-492
[10]   Analysis of Breast Cancer Mortality in the US-1975 to 2019 [J].
Caswell-Jin, Jennifer L. ;
Sun, Liyang P. ;
Munoz, Diego ;
Lu, Ying ;
Li, Yisheng ;
Huang, Hui ;
Hampton, John M. ;
Song, Juhee ;
Jayasekera, Jinani ;
Schechter, Clyde ;
Alagoz, Oguzhan ;
Stout, Natasha K. ;
Trentham-Dietz, Amy ;
Lee, Sandra J. ;
Huang, Xuelin ;
Mandelblatt, Jeanne S. ;
Berry, Donald A. ;
Kurian, Allison W. ;
Plevritis, Sylvia K. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2024, 331 (03) :233-241