Toward rapid silica analysis of CPDM samples: Deposition of recovered dust and analysis by FTIR

被引:1
|
作者
Greth, August [1 ]
Sarver, Emily [1 ]
机构
[1] Virginia Polytech Inst & State Univ, Dept Min & Minerals Engn, Blacksburg, VA 24061 USA
关键词
Continuous personal dust monitor; Fourier transform infrared spectroscopy; respirable coal mine dust; respirable crystalline silica; RESPIRABLE CRYSTALLINE SILICA; X-RAY-DIFFRACTION; COAL-MINE DUST; INFRARED SPECTROMETRY; CONTINUED INCREASE; QUARTZ; FILTERS; PREVALENCE;
D O I
10.1080/15459624.2024.2421008
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The ongoing resurgence of severe Coal Workers' Pneumoconiosis in the US has been linked to overexposure to respirable crystalline silica (RCS, which is predominantly present as quartz and regulated as such). Capabilities that enable more frequent RCS monitoring are highly sought. Recent developments include field-based quartz analysis of traditional filter samples-collected on polyvinyl chloride (PVC) filters-using portable Fourier Transform Infrared spectroscopy (FTIR). However, most respirable dust samples in US coal mines are collected with a continuous personal dust monitor (CPDM) that enables real-time tracking of total respirable dust mass concentration. FTIR cannot directly analyze the collected dust sample due to the materials and construction of the sampling substrate. To address this issue, a simple three-step method was envisioned wherein the dust could be recovered into a suspension, redeposited onto a PVC filter using a syringe filter apparatus, and then analyzed by FTIR. The current study was conducted to develop the redeposition and analysis steps. It specifically considers the issues of the PVC filter size and deposition pattern yielded by typical filtration apparatuses and the FTIR scanning locations to establish a model that predicts quartz mass from the spectral data. Of the options tested here, the following combination was found to be optimal: 25-mm PVC filter with dust deposition using an inline syringe filter holder (which yields a "wheel and spoke" pattern), and FTIR analysis at four center-offset locations (90 degrees apart, 8-mm from the center) from which the spectral data were averaged. Under these conditions, the predicted quartz mass on filters with respirable dust deposited from one of two geologic source materials (i.e., representing real coal mine silica sources) was observed to have a standard error of 0.011 mg (11 mu g) for samples with an expected quartz mass of less than 0.150 mg (which equated to a total sample mass of less than about 1.5 mg). For samples with higher expected quartz masses, standard error increased, suggesting that dust deposition becomes less uniform with increasing total sample mass.
引用
收藏
页码:87 / 100
页数:14
相关论文
共 50 条
  • [31] Analysis of Dust Deposition on PV Arrays by CFD Simulation
    Wu, Zuyu
    Li, Wei
    Kuka, Sokol
    Alkahtani, Mohammed
    45TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2019), 2019, : 5439 - 5443
  • [32] Comparison of different digestion methods for elemental analysis of airborne dust and dust deposition
    Lumpp, R.
    Klein, M.
    Bieber, E.
    Bunzel, F.
    Eckermann, U.
    Frels, C.
    Guenther, W.
    Hagemann, C.
    Koch, C.
    Olschewski, A.
    Temme, C.
    GEFAHRSTOFFE REINHALTUNG DER LUFT, 2012, 72 (1-2): : 64 - 71
  • [33] An analysis of the dust halo and extinction toward X Persei
    Valencic, Lynne A.
    Smith, Randall K.
    ASTROPHYSICAL JOURNAL, 2008, 672 (02): : 984 - 995
  • [34] Study on rapid and nondestructive analysis of danshen formula particles by FTIR
    Wu, Jing
    Sun, Su-Qin
    Zhou, Qun
    Yu, Lu
    Guang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis, 2007, 27 (08): : 1535 - 1538
  • [35] Rapid analysis of emergency urine and water samples
    S. L. Maxwell
    Journal of Radioanalytical and Nuclear Chemistry, 2008, 275 : 497 - 502
  • [36] Rapid analysis of emergency urine and water samples
    Maxwell, S. L., III
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2008, 275 (03) : 497 - 502
  • [37] Study on rapid and nondestructive analysis of danshen formula particles by FTIR
    Wu, Jing
    Sun, Su-qin
    Zhou, Qun
    Yu, Lu
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2007, 27 (08) : 1535 - 1538
  • [38] Rapid procedure for the analysis of radionuclides in liquid samples
    Parsa, Bahman
    Henitz, James
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2013, 245
  • [39] ANALYSIS OF COMPLEX FLAVOR SAMPLES - GC-FTIR SPECTROSCOPY AS A RAPID IDENTIFICATION TOOL USING A SPECIFIC FTIR-VAPOR-PHASE FLAVOR-LIBRARY
    FISCHBOECK, G
    KELLNER, R
    PFANNHAUSER, W
    AGRICULTURE, FOOD CHEMISTRY AND THE CONSUMER, VOLS 1 AND 2: THE CONSUMER AND FOOD, ANALYTICAL FOOD CHEMISTRY AND AGRICULTURAL PRODUCTION, BIOTECHNOLOGY AND BIOASSAYS - IMPACT OF TECHNOLOGY ON FOOD QUALITY, FOOD CHEMISTRY AND QUALITY ASSURANCE, 1989, : 631 - 633
  • [40] Inverse Analysis of Rapid and Localized Energy Deposition
    S. G. Lambrakos
    J. G. Michopoulos
    Journal of Materials Engineering and Performance, 2010, 19 : 928 - 935