Non-metal framework for removable partial dentures - A 2-year follow-up clinical report

被引:0
|
作者
Gomes, Isabel [1 ]
Goncalves, Joana [2 ]
Martins, Joao Paulo [1 ]
Lopes, Luis Pires [1 ,3 ]
机构
[1] Univ Lisbon, Fac Med Dentaria, Unidade Invest & Ciencias Orais & Biomed UICOB, Lisbon, Portugal
[2] Univ Lisbon, Fac Med Dentaria, Lisbon, Portugal
[3] Lab Instrumentacao Engn Biomed & Fis Radiacao LIBP, Lisbon, Portugal
来源
REVISTA PORTUGUESA DE ESTOMATOLOGIA MEDICINA DENTARIA E CIRURGIA MAXILOFACIAL | 2024年 / 65卷 / 03期
关键词
CAD-CAM; PEEK; Removable partial denture; DENTAL IMPLANTS; PEEK; PROSTHESIS;
D O I
10.24873/j.rpemd.2024.10.1223
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Traditional removable partial dentures (RPDs) with cobalt-chromium frameworks have been used for several decades, restoring the masticatory function. However, these frameworks have been documented as aesthetically unacceptable due to the display of metal clasps. The patients' increased demands regarding the aesthetic aspects of rehabilitation treatment led to the introduction of new, more aesthetic materials in clinical practice. One of the main materials is polyetheretherketone (PEEK). This clinical report presents PEEK as an alternative material for fabricating RPD frameworks for a Class III Kennedy partial edentulous mandible. The framework was constructed using CAD/CAM manufacturing, and the process combined laboratory scanning, digital framework design, resin try-in milling, and PEEK framework milling. The framework showed good adaptation to the abutment teeth and surrounding tissues. The patient was followed for 2 years without complaints and was grateful for the aesthetics. During this period, there were no signs of degradation in the framework, and the clasps were still as retentive as they were at the initial appointment, with only some pigmentation of the structure being observed. (Rev Port Estomatol Med Dent Cir Maxilofac. 2024;65(3):148-155) (c) 2024 Sociedade Portuguesa de Estomatologia e Medicina Dentaria. Published by SPEMD. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:148 / 155
页数:8
相关论文
共 50 条
  • [21] Osseointegrated implants in a patient with Papillon-Lefevre syndrome -: A 41/2-year follow-up
    Ullbro, C
    Crossner, CG
    Lundgren, T
    Stålblad, PÅ
    Renvert, S
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2000, 27 (12) : 951 - 954
  • [22] Outcome of an uncemented hydroxyapatite coated hemiarthroplasty for displaced femoral neck fractures: a clinical and radiographic 2-year follow-up study
    Eschen, Jacob
    Kring, Soren
    Brix, Michael
    Ban, Ilija
    Troelsen, Anders
    HIP INTERNATIONAL, 2012, 22 (05) : 574 - 579
  • [23] Retrospective clinical evaluation of 2-to 6-unit implant-supported fixed partial dentures: Mean follow-up of 9 years
    Chrcanovic, Bruno R.
    Kisch, Jeno
    Larsson, Christel
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2020, 22 (02) : 201 - 212
  • [24] Bone Regeneration in the Anterior Maxilla With Titanium Mesh and Advanced-Platelet-Rich Fibrin: A Case Report With 2-Year Follow-up
    Araujo, Carlos Roberto Garcia
    de Araujo, Roberto Carlos
    Araujo, Cristiano Garcia
    Carvalho, Ana Paula
    Cota, Luis Otavio Miranda
    Martins-Junior, Paulo Antonio
    Pelegrine, Andre Antonio
    JOURNAL OF ORAL IMPLANTOLOGY, 2024, 50 (05) : 514 - 518
  • [25] Immediate, non-submerged, root-analogue zirconia implants placed into single-rooted extraction sockets: 2-year follow-up of a clinical study
    Pirker, W.
    Kocher, A.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2009, 38 (11) : 1127 - 1132
  • [26] Relapse and failure rates between CAD/CAM and conventional fixed retainers: a 2-year follow-up of a randomized controlled clinical trial
    Tran, Giau
    Rucker, Ryan
    Foley, Patrick
    Bankhead, Brent
    Adel, Samar M.
    Kim, Ki Beom
    EUROPEAN JOURNAL OF ORTHODONTICS, 2024, 46 (01)
  • [27] Influence of Implant-Prosthetic Connection on Peri-implant Bone Loss: A Prospective Clinical Trial with 2-Year Follow-up
    Agustin-Panadero, Ruben
    Leon-Martinez, Raquel
    Labaig-Rueda, Carlos
    Faus-Lopez, Joan
    Fernanda Sola-Ruiz, Ma
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (04) : 963 - 968
  • [28] Polyetheretherketone versus titanium CAD-CAM framework for implant-supported fixed complete dentures: a retrospective study with up to 5-year follow-up
    Wang, Jing
    Wu, Peng
    Liu, Hai-Lin
    Zhang, Ling
    Liu, Li-Peng
    Ma, Chu-Fan
    Chen, Ji-Hua
    JOURNAL OF PROSTHODONTIC RESEARCH, 2022, 66 (02) : 279 - 287
  • [29] Monolithic implant-supported lithium disilicate (LS2) crowns in a complete digital workflow: A prospective clinical trial with a 2-year follow-up
    Joda, Tim
    Ferrari, Marco
    Bragger, Urs
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2017, 19 (03) : 505 - 511
  • [30] Prospective study with a 2-year follow-up on immediate implant loading in the edentulous mandible with a definitive restoration using intra-oral welding
    Degidi, Marco
    Nardi, Diego
    Piattelli, Adriano
    CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (04) : 379 - 385