Evaluation of the impact of cardiac implantable electronic devices on cine MRI for real-time adaptive cardiac radioablation on a 1.5 T MR-linac

被引:0
|
作者
Akdag, Osman [1 ]
Mandija, Stefano [1 ,2 ]
Borman, Pim T. S. [1 ]
Tzitzimpasis, Paris [1 ]
van Lier, Astrid L. H. M. W. [1 ]
Keesman, Rick [3 ]
Raaymakers, Bas W. [1 ]
Fast, Martin F. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiotherapy, Heidelberglaan 100, NL-3584 CX Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Ctr Image Sci, Computat Imaging Grp MR Diag & Therapy, Utrecht, Netherlands
[3] Radboud Univ Nijmegen, Med Ctr, Dept Radiotherapy, Nijmegen, Netherlands
关键词
cardiac radiotherapy; MRI-guided radiotherapy; real-time; MAGNETIC-RESONANCE; TREATING PATIENTS; RADIATION; SAFETY;
D O I
10.1002/mp.17438
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Stereotactic arrhythmia radioablation (STAR) is a novel treatment approach for refractory ventricular tachycardia (VT). The risk of treatment-induced toxicity and geographic miss can be reduced with online MRI-guidance on an MR-linac. However, most VT patients carry cardiac implantable electronic devices (CIED), which compromise MR images. Purpose: Robust MR-linac imaging sequences are required for cardiac visualization and accurate motion monitoring in presence of a CIED during MRI-guided STAR. We optimized two clinically available cine sequences for cardiorespiratory motion estimation in presence of a CIED on a 1.5 T MR-linac. The image quality, motion estimation accuracy, and geometric fidelity using these cine sequences were evaluated. Methods: Clinically available 2D balanced steady-state free precession (bSSFP, voxel size = 3.0 3.0 10 mm(3), T-scan = 96 ms, bandwidth (BW) = 1884 Hz/px) and -spoiled gradient echo (-GRE, voxel size = 4.0 4.0 10 mm(3), T-scan = 97 ms, BW = 500 Hz/px) sequences were adjusted for real-time cardiac visualization and cardiorespiratory motion estimation on a 1.5 T Unity MR-linac (Elekta AB, Stockholm, Sweden), while complying with safety guidelines for MRI in presence of CIEDs (specific absorption rate < 2 W/kg and dB/dt< 80 mT/s). Cine acquisitions were performed in five healthy volunteers, with and without an implantable cardioverter- defibrillator (ICD) placed on the clavicle, and a VT patient. Generalized divergence-curl (GDC) deformable image registration (DIR) was used for automated landmark motion estimation in the left ventricle (LV). Gaussian processes (GP), a machine-learning technique, was trained using GDC landmarks and deployed for real-time cardiorespiratory motion prediction. B0-mapping was performed to assess geometric image fidelity in the presence of CIEDs. Results: CIEDs introduced banding artifacts partially obscuring cardiac structures in bSSFP acquisitions. In contrast, the T-1-GRE was more robust to CIED-induced artifacts at the expense of a lower signal-to-noise ratio. In presence of an ICD, image-based cardiorespiratory motion estimation was possible for 85% (100%) of the volunteers using the bSSFP (T-1-GRE) sequence. The in-plane 2D root-mean-squared deviation (RMSD) range between GDC-derived landmarks and manual annotations using the bSSFP (T-1-GRE) sequence was 3.1-3.3 (3.3-4.1) mm without ICD and 4.6-4.6 (3.2-3.3) mm with ICD. Without ICD, the RMSD between the GP-predictions and GDC-derived landmarks ranged between 0.9 and 2.2 mm (1.3-3.0 mm) for the bSSFP (T-1-GRE) sequence. With ICD, the RMSD between the GP-predictions and GDC-derived landmarks ranged between 1.3 and 2.2 mm (1.2-3.2 mm) using the bSSFP (T-1-GRE) sequence resulting in an RMSD-increase of 42%-143% (bSSFP) and -61%-142% (T-1-GRE). Lead-induced spatial distortions ranged between -0.2 and 0.2 mm (-0.7-1.2 mm) using the bSSFP (T1-GRE) sequence. The 98(th) percentile range of the spatial distortions in the gross target volume of the patient was between 0.0 and 0.4 mm (0.0-1.8 mm) when using bSSFP (T-1-GRE). Conclusions: Tailored bSSFP and T-1-GRE sequences can facilitate real-time cardiorespiratory estimation using GP trained with GDC-derived landmarks in the majority of landmark locations in the LV despite the presence of CIEDs. The need for high temporal resolution noticeably reduced achievable spatial resolution of the cine MRIs. However, the effect of the CIED-induced artifacts is device, patient and sequence dependent and requires specific assessment per case.
引用
收藏
页码:99 / 112
页数:14
相关论文
共 16 条
  • [11] Computationally Efficient Implicit Training Strategy for Unrolled Networks (IMUNNE): A Preliminary Analysis Using Accelerated Real-Time Cardiac Cine MRI
    Iakovlev, Nikolay
    Schiffers, Florian A.
    Tapia, Santiago L.
    Shen, Daming
    Hong, Kyungpyo
    Markl, Michael
    Lee, Daniel C.
    Katsaggelos, Aggelos K.
    Kim, Daniel
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2025, 72 (01) : 187 - 197
  • [12] Initial clinical experience of Stereotactic Body Radiation Therapy (SBRT) for liver metastases, primary liver malignancy, and pancreatic cancer with 4D-MRI based online adaptation and real-time MRI monitoring using a 1.5 Tesla MR-Linac
    Hal, William A.
    Straza, Michael W.
    Chen, Xinfeng
    Mickevicius, Nikolai
    Erickson, Beth
    Schultz, Chris
    Awan, Musaddiq
    Ahunbay, Ergun
    Li, X. Allen
    Paulson, Eric S.
    PLOS ONE, 2020, 15 (08):
  • [13] Modifying the trajectory of epicardial leads can substantially reduce MRI-induced RF heating in pediatric patients with a cardiac implantable electronic device at 1.5T
    Jiang, Fuchang
    Bhusal, Bhumi
    Nguyen, Bach
    Monge, Michael
    Webster, Gregory
    Kim, Daniel
    Bonmassar, Giorgio
    Popsecu, Andrada R.
    Golestanirad, Laleh
    MAGNETIC RESONANCE IN MEDICINE, 2023, 90 (06) : 2510 - 2523
  • [14] The use of 1.5 T magnetic resonance imaging for therapeutic decisions in patients with cardiac implantable electronic devices and significant neurological, neurosurgical and neuro-oncology diagnostic indications
    Hawryluk, Lukasz
    Sterlinski, Maciej
    Marczak, Magdalena
    Misko, Jolanta
    Podgorski, Jan Krzysztof
    Szwed, Hanna
    NEUROLOGIA I NEUROCHIRURGIA POLSKA, 2015, 49 (01) : 16 - 23
  • [15] Fully automatic, retrospective enhancement of real-time acquired cardiac cine MR images using image-based navigators and respiratory motion-corrected averaging
    Kellman, Peter
    Chefd'hotel, Christophe
    Lorenz, Christine H.
    Mancini, Christine
    Arai, Andrew E.
    McVeigh, Elliot R.
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (04) : 771 - 778
  • [16] Feasibility of free-breathing, GRAPPA-based, real-time cardiac cine assessment of left-ventricular function in cardiovascular patients at 3T
    Zhu, Xiaomei
    Schwab, Felix
    Marcus, Roy
    Hetterich, Holger
    Theisen, Daniel
    Kramer, Harald
    Notohamiprodjo, Mike
    Schlett, Christopher L.
    Nikolaou, Konstantin
    Reiser, Maximilian F.
    Bamberg, Fabian
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (05) : 849 - 855