Rotating multi-channel high-sensitivity integrating sphere gas sensing based on NDIR

被引:0
|
作者
Zhang, Songsong [1 ]
Wu, Haitao [1 ,2 ]
Liu, Shuning [1 ,2 ]
Zhang, Long [1 ]
Xu, Xiangbao [1 ]
Luo, Huiming [1 ]
Chen, Jiachang [1 ]
Li, Jialin [1 ]
He, Ting [1 ,2 ]
Zhong, Fang [1 ,2 ]
Li, Qing [1 ,2 ]
Hu, Weida [1 ,2 ]
机构
[1] Univ Chinese Acad Sci, Hangzhou Inst Adv Study, Sch Phys & Optoelect Engn, Hangzhou 310024, Peoples R China
[2] Chinese Acad Sci, Shanghai Inst Tech Phys, State Key Lab Infrared Phys, Shanghai 200083, Peoples R China
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2025年 / 428卷
基金
中国国家自然科学基金;
关键词
NDIR; Integrating sphere system; Multi-channel; Rotating; Gas detection; CARBON-DIOXIDE; MU-M; SENSOR; SPECTROSCOPY; SYSTEM; CO2;
D O I
10.1016/j.snb.2025.137242
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Non-dispersive infrared (NDIR) gas detection is capable of detecting multiple gases simultaneously and has the advantages of high stability, selectivity and fast response time, making it ideal for greenhouse gas detection. However, in traditional NDIR gas sensors, the infrared detector must be paired with a bandpass filter to select the target gas, and multiple pairs of bandpass filters and detectors are required for mixed-gas testing, which makes the sensor bulky and increases the cost. Here, we propose a gas sensor based on NDIR with a rotating multichannel integrating sphere. Unlike the traditional detector array approach, we utilize the symmetry of the integrating sphere and integrate multiple filter channels along the equatorial direction. By simple rotation, multiple gases can be measured simultaneously, significantly reducing costs. At the same time, relying on the ultra-long equivalent optical range provided by the integrating sphere structure, we are able to achieve ultrahigh sensitivity while miniaturizing the sensor. Experiments show that the detection limits for five common gases at 25 degrees C demonstrate, CO2, C2H2, CH4, N2O, and CO, are 1.87 ppm, 8.52 ppm, 23.4 ppm, 3.64 ppm, and 40.66 ppm, respectively. Furthermore, we have designed a high-precision concentration reconstruction scheme for the spectrally overlapping gases, which can effectively compensate for the errors caused by cross-interference problems through algorithms. The integrating sphere system in this paper has the advantages of miniaturization multi-channel and high sensitivity, which provides a new method for NDIR mixed gas detection.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Terahertz metasurfaces based on bound states in the continuum (BIC) for high-sensitivity refractive index sensing
    Liu, Xinyan
    Li, Fuyu
    Li, Yuanxun
    Tang, Tingting
    Liao, Yulong
    Lu, Yongcheng
    Wen, Qiye
    OPTIK, 2022, 261
  • [32] A high-sensitivity liquid concentration-sensing structure based on a phoxonic crystal slot nanobeam
    Li, Ke-Yu
    Sun, Xiao-Wei
    Song, Ting
    Wen, Xiao-Dong
    Wang, Yi-Wen
    Liu, Xi-Xuan
    Liu, Zi-Jiang
    JOURNAL OF APPLIED PHYSICS, 2022, 131 (02)
  • [33] Characteristics of a new multi-channel sensing device based on C-type photonic crystal fibers
    Wu, Qi-lu
    Zhao, Yong
    Zhang, Ya-nan
    Yang, Yang
    OPTICS AND LASER TECHNOLOGY, 2021, 134
  • [34] A multi-channel optical sensing system based on back propagation neural network for mixed ion solution
    Hou J.
    Peng J.
    Liu K.
    Liang Z.
    Yao J.
    Li J.
    Tang T.
    Optik, 2023, 291
  • [35] A High Sensitivity Gas Sensing Mechanism Based on Mode Localization and Adsorption Expansion
    Xiang, Jiajia
    Xia, Cao
    Lin, Sijian
    Zhao, Zhujie
    Zhang, Lijia
    Xia, Yuanlin
    He, Liang
    Wang, Dong F.
    Wang, Zhuqing
    IEEE SENSORS JOURNAL, 2024, 24 (07) : 9734 - 9743
  • [36] High-sensitivity optical sensing of temperature based on side-polished fiber with polymer nanoporous cladding
    Zhong, Yongchun
    Li, Shan
    Tang, Li
    Chen, Zhe
    Yu, Jianhui
    Guan, Heyuan
    Lu, Huihui
    Zhang, Yong
    OPTICAL ENGINEERING, 2016, 55 (10)
  • [37] A FPGA-Based High Speed Multi-Channel Simultaneous Signal Acquisition Method for PET
    Hu, W.
    Choi, Y.
    Jung, J. H.
    Kang, J. H.
    Min, B. J.
    Huh, Y. S.
    Shin, S. H.
    Lim, H. K.
    Chung, Y. H.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2870 - +
  • [38] Fault Diagnosis of High-speed Train Bogie Based on Spectrogram and Multi-channel Voting
    Su, Liyuan
    Ma, Lei
    Qin, Na
    Huang, Deqing
    Kemp, Andrew
    PROCEEDINGS OF 2018 IEEE 7TH DATA DRIVEN CONTROL AND LEARNING SYSTEMS CONFERENCE (DDCLS), 2018, : 22 - 26
  • [39] A new multi-channel synchronous sampling technique based on high-speed serial communication
    Jiang, Lei
    Zhou, Hualiang
    Zheng, Yuping
    Xia, Yu
    Yao, Jiwen
    Wu, Tonghua
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2012, 36 (09): : 82 - 85
  • [40] Design of a multi-channel high speed FIFO applied to HDLC processor based on PCI bus
    Huang, B
    Wang, ZG
    Qiao, LF
    Lu, YL
    2002 INTERNATIONAL CONFERENCE ON COMMUNICATIONS, CIRCUITS AND SYSTEMS AND WEST SINO EXPOSITION PROCEEDINGS, VOLS 1-4, 2002, : 1476 - 1480