Biomechanical properties of porcine cornea; planar biaxial tests versus uniaxial tensile tests

被引:0
|
作者
Hatami-Marbini, Hamed [1 ]
Emu, Md Esharuzzaman [1 ]
机构
[1] Univ Illinois, Mech & Ind Engn Dept, Chicago, IL USA
关键词
Porcine cornea; Anisotropy; Biaxial experiments; Uniaxial tensile tests; MECHANICAL-PROPERTIES; BEHAVIOR;
D O I
10.1016/j.jmbbm.2025.106955
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The cornea is a transparent tissue whose mechanical properties are important for its optical and physiological functions. The mechanical properties of cornea depend on the composition and microstructure of its extracellular matrix, which is composed of collagen fibrils with preferential orientations. The present research was done in order to characterize corneal mechanical response using the biaxial mechanical testing method and to compare biaxial measurements with those found from uniaxial tensile tests. For this purpose, thirty square-shaped specimens excised from the center of porcine cornea were mounted into an ElectroForce TestBench device such that their superior/inferior (SI) and nasal/temporal (NT) meridians were aligned with motor axes. Furthermore, ten corneal strips dissected from the NT direction (n = 5) and SI direction (n = 5) were mounted into an RSA-G2 Solid Analyzer testing machine. The biaxial experiments were performed at stretch ratios of 1:1, 1:0.5, 0.5:1, 1:0.01, and 0.01:1 and displacement rates of 2 mm/min (n = 20) and 10 mm/min (n = 10). The uniaxial experiments were done using the displacement rate of 2 mm/min. The planar square-shaped samples tested under equibiaxial loading showed similar mechanical response in NT and SI directions. Furthermore, uniaxial experiments revealed no significant difference in tensile response of corneal strips excised from NT and SI directions. However, equibiaxial testing tensile stresses were significantly larger than those found from uniaxial tensile measurements. The mechanical behavior of cornea in biaxial tests was dependent on the applied stretch ratio. The differences and similarities between uniaxial and biaxial experimental measurements were discussed and it was concluded that the planar biaxial testing method characterized the mechanical response of cornea by mimicking its in vivo loading state more closely than uniaxial experiments.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] NUMERICAL STUDY OF CRUCIFORM SPECIMENS FOR BIAXIAL TENSILE TESTS
    Puente Medellin, Luis F.
    Balvantin, Antonio
    Diosdado-De la Pena, J. A.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2016, VOL. 14, 2017,
  • [22] Size Effects on Mechanical Properties of Copper Thin Sheet in Uniaxial Tensile Tests
    Gong, Feng
    Guo, Bin
    MATERIALS SCIENCE-MEDZIAGOTYRA, 2014, 20 (04): : 509 - 512
  • [23] Uniaxial and biaxial mechanical properties of porcine linea alba
    Cooney, Gerard M.
    Moerman, Kevin M.
    Takaza, Michael
    Winter, Des C.
    Simms, Ciaran K.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2015, 41 : 68 - 82
  • [24] Uniaxial and equi-biaxial tension tests of silicone elastomer
    Meier, P
    Khader, S
    Preuss, R
    Dietrich, J
    Voges, D
    CONSTITUTIVE MODELS FOR RUBBER III, 2003, : 99 - 106
  • [25] Deformation Behavior of the Mg-Zn-Ca-Ce Alloy Sheets Subjected to Uniaxial and Biaxial Tensile Tests
    Wang, Guangang
    Huang, Guangsheng
    Liu, Ke
    Zhang, Junlei
    Jiang, Bin
    Tang, Aitao
    Pan, Fusheng
    METALS AND MATERIALS INTERNATIONAL, 2021, 27 (11) : 4322 - 4332
  • [26] A comparison of biomechanical properties between human and porcine cornea
    Zeng, YJ
    Yang, J
    Huang, K
    Lee, ZH
    Lee, XY
    JOURNAL OF BIOMECHANICS, 2001, 34 (04) : 533 - 537
  • [27] Uniaxial Cyclic and Tensile Tests on Structural Metallic Materials
    Hartloper, Alexander R.
    Ozden, Selimcan
    Sousa, Albano de Castro e
    Lignos, Dimitrios G.
    JOURNAL OF STRUCTURAL ENGINEERING, 2023, 149 (05)
  • [28] Relationship between uniaxial and strip biaxial tensile properties of fabrics
    Zheng, Jiaming
    Komatsu, Takuya
    Takatera, Masayuki
    Inui, Shigeru
    Bao, Limin
    Shimizu, Yoshio
    TEXTILE RESEARCH JOURNAL, 2008, 78 (03) : 224 - 231
  • [29] Influence of analytical methods versus clamping procedure on biomechanical response of cornea through experimental strip tests
    Khan, M. Arsalan
    Elsheikh, Ahmed
    Rizvi, Z. H.
    Khan, I. Ahmad
    MATERIALS TODAY-PROCEEDINGS, 2021, 44 : 4375 - 4380
  • [30] Characterization of Hyperelastic (Rubber) Material Using Uniaxial and Biaxial Tension Tests
    Jamil, Adeel Yawar
    Irshad, Muhammad Ahsan
    Azmat, Zeeshan
    ADVANCED MATERIALS FOR APPLIED SCIENCE AND TECHNOLOGY II, 2012, 570 : 1 - +