Reasons for Explantations of Posterior Chamber Phakic Intraocular Lenses in 1,490 Eyes

被引:0
|
作者
Coskunseven, Efekan [1 ,2 ]
Kayhan, Belma [3 ]
机构
[1] Zincirlikuyu Med Hosp, Refract Surg Dept, Istanbul, Turkiye
[2] Istanbul Yeni Yuzyil Univ, Fac Hlth Sci, Istanbul, Turkiye
[3] Univ Hlth Sci, Sultan II Abdulhamid Han Training & Res Hosp, Ophthalmol Dept, Istanbul, Turkiye
关键词
IMPLANTABLE COLLAMER LENS; OPTIMIZATION; MYOPIA;
D O I
10.3928/1081597X-20240913-03
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To investigate the reasons for the removal and/ or exchange of posterior chamber phakic intraocular lenses (PCPIOLs) and the outcomes of these procedures. METHODS: In this retrospective study, PCPIOL implantations performed between January 2015 and June 2023 in a single center were reviewed. The study group consisted of the files of eyes with removed and/or exchanged PCPIOL. Visual acuities, refraction errors, endothelial cell counts, and measurements of the vault before and after exchanges were recorded. Reasons for removal and/or exchange were evaluated. The tuck-and-pull technique was used in all explantations. RESULTS: Twenty-three of 1,490 eyes with PCPIOL implantation required removal and/or exchange. Of the explanted eyes, 17 were implanted with PCPIOLs for myopia (1.21% of all myopic corrections) and 6 were implanted with PCPIOLs for hyperopia (6.59% of all hyperopic corrections). The most common reason for removal and/or exchanges after implantation was inappropriate vault (10 of the 23 total removals and/or exchanges), followed by cataract development (7 of the 23 total removals and/or exchanges). A comparison of the biometric characteristics of eyes with PCPIOL removal and/ or exchange due to inappropriate vault with other PCPIOL implantations showed that anterior chamber depth, PCPIOL length, and white-to-white distance were significantly higher in the group of explanted eyes (P < .05). All eyes with high vault in myopic patients had a 13.2- or 13.7-mm length PCPIOL. CONCLUSIONS: The main reason for PCPIOL removal and/ or exchange is vault values outside the ideal limits and cataract development. Before ordering 13.2- and 13.7-mm long PCPIOLs, biometric data of both eyes and recommended PCPIOL sizes should be carefully reviewed.
引用
收藏
页码:e797 / e803
页数:7
相关论文
共 50 条
  • [21] Posterior chamber phakic intra lenses to improve outcomes in keratoconus patients
    Esteve-Taboada, Jose Juan
    Dominguez-Vicent, Alberto
    Ferrer-Blasco, Teresa
    Alfonso, Jose F.
    Montes-Mico, Robert
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (01) : 115 - 130
  • [22] Intraocular lens power calculation in a posterior chamber phakic intraocular lens implanted eye
    Yasa, Dilek
    Kose, Bulent
    Sucu, Mehmet Emin
    Agca, Alper
    INTERNATIONAL OPHTHALMOLOGY, 2020, 40 (08) : 2017 - 2022
  • [23] Posterior chamber collagen copolymer phakic intraocular lenses to correct myopia: Five-year follow-up
    Alfonso, Jose F.
    Baamonde, Begona
    Fernandez-Vega, Luis
    Fernandes, Paulo
    Gonzalez-Meijome, Jose M.
    Montes-Mico, Robert
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (05) : 873 - 880
  • [24] Intraocular lens power calculation in a posterior chamber phakic intraocular lens implanted eye
    Dilek Yaşa
    Bülent Köse
    Mehmet Emin Sucu
    Alper Ağca
    International Ophthalmology, 2020, 40 : 2017 - 2022
  • [25] Bilensectomy: Safety and Visual Outcomes in Angle-Supported, Iris-Fixated, and Posterior Chamber Phakic Intraocular Lenses
    Vargas, Veronica
    Alio, Jorge L.
    del Barrio, Jorge L. Alio
    Canto-Cerdan, Mario
    Barraquer, Rafael I.
    Duch, Francisco
    Marinho, Antonio
    JOURNAL OF REFRACTIVE SURGERY, 2023, 39 (02) : 128 - +
  • [26] Outcome of posterior chamber phakic intraocular lens procedure to correct myopia
    Al Sabaani, Nasser
    Al Assiri, Abdullah
    Al Torbak, Abdullah
    Al Motawa, Saeed
    SAUDI JOURNAL OF OPHTHALMOLOGY, 2013, 27 (04) : 259 - 266
  • [27] Simulated prototype of posterior chamber phakic intraocular lens for presbyopia correction
    Perez-Vives, Cari
    Ferrer-Blasco, Teresa
    Cervino-Exposito, Alejandro
    Madrid-Costa, David
    Montes-Mico, Robert
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (10) : 2266 - 2273
  • [28] Implanting a posterior chamber phakic intraocular lens in highly myopic eyes with peripheral primary iris and ciliary body cysts
    Zhao, Jing
    Luo, Dongqiang
    Sun, Yong
    Niu, Lingling
    Zhao, Feng
    Wang, Xiaoying
    Wang, Hua
    Chen, Qian
    Zhou, Xingtao
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2019, 29 (02) : 171 - 177
  • [29] Comparison of clinical outcomes and vault between two types of posterior phakic intraocular lenses in correction of myopia and myopic astigmatism
    Chingan, Alexandre
    El Maftouhi, Adil
    Gobeaut, M.
    El Kaim, Pauline
    Baudouin, Christophe
    Trinh, Liem
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2025,
  • [30] In vivo optical quality of posterior-chamber phakic implantable collamer lenses with a central port
    Montes-Mico, Robert
    Pastor-Pascual, Francisco
    Artiaga-Elordi, Enrique
    Ruiz-Mesa, Ramon
    Tana-Rivero, Pedro
    EYE AND VISION, 2021, 8 (01)