Reasons for Explantations of Posterior Chamber Phakic Intraocular Lenses in 1,490 Eyes

被引:0
|
作者
Coskunseven, Efekan [1 ,2 ]
Kayhan, Belma [3 ]
机构
[1] Zincirlikuyu Med Hosp, Refract Surg Dept, Istanbul, Turkiye
[2] Istanbul Yeni Yuzyil Univ, Fac Hlth Sci, Istanbul, Turkiye
[3] Univ Hlth Sci, Sultan II Abdulhamid Han Training & Res Hosp, Ophthalmol Dept, Istanbul, Turkiye
关键词
IMPLANTABLE COLLAMER LENS; OPTIMIZATION; MYOPIA;
D O I
10.3928/1081597X-20240913-03
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To investigate the reasons for the removal and/ or exchange of posterior chamber phakic intraocular lenses (PCPIOLs) and the outcomes of these procedures. METHODS: In this retrospective study, PCPIOL implantations performed between January 2015 and June 2023 in a single center were reviewed. The study group consisted of the files of eyes with removed and/or exchanged PCPIOL. Visual acuities, refraction errors, endothelial cell counts, and measurements of the vault before and after exchanges were recorded. Reasons for removal and/or exchange were evaluated. The tuck-and-pull technique was used in all explantations. RESULTS: Twenty-three of 1,490 eyes with PCPIOL implantation required removal and/or exchange. Of the explanted eyes, 17 were implanted with PCPIOLs for myopia (1.21% of all myopic corrections) and 6 were implanted with PCPIOLs for hyperopia (6.59% of all hyperopic corrections). The most common reason for removal and/or exchanges after implantation was inappropriate vault (10 of the 23 total removals and/or exchanges), followed by cataract development (7 of the 23 total removals and/or exchanges). A comparison of the biometric characteristics of eyes with PCPIOL removal and/ or exchange due to inappropriate vault with other PCPIOL implantations showed that anterior chamber depth, PCPIOL length, and white-to-white distance were significantly higher in the group of explanted eyes (P < .05). All eyes with high vault in myopic patients had a 13.2- or 13.7-mm length PCPIOL. CONCLUSIONS: The main reason for PCPIOL removal and/ or exchange is vault values outside the ideal limits and cataract development. Before ordering 13.2- and 13.7-mm long PCPIOLs, biometric data of both eyes and recommended PCPIOL sizes should be carefully reviewed.
引用
收藏
页码:e797 / e803
页数:7
相关论文
共 50 条
  • [1] Phakic posterior chamber intraocular lenses
    Kook, Daniel
    Mayer, Wolfgang J.
    Steinwender, Gernot
    Kohnen, Thomas
    SPEKTRUM DER AUGENHEILKUNDE, 2019, 33 (06) : 160 - 164
  • [2] A review of posterior chamber phakic intraocular lenses
    Reinstein, Dan Z.
    MacGregor, Cheryl
    Archer, Timothy J.
    Gupta, Ruchi
    Potter, Joseph G.
    CURRENT OPINION IN OPHTHALMOLOGY, 2024, 35 (02) : 138 - 146
  • [3] Posterior chamber phakic intraocular lenses after penetrating keratoplasty
    Alfonso, Jose F.
    Lisa, Carlos
    Abdelhamid, Abdelhamid
    Montes-Mico, Robert
    Poo-Lopez, Arancha
    Ferrer-Blasco, Teresa
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (07) : 1166 - 1173
  • [4] Posterior Chamber Phakic Intraocular Lenses for the Correction of Myopia: Factors Influencing the Postoperative Refraction
    Serra, Pedro
    Trancon, Angel Sanchez
    Sierra, Oscar Torrado
    Baptista, Antonio
    Manito, Santiago Cerpa
    OPTICS, 2021, 2 (04): : 292 - 305
  • [5] Femtosecond laser-assisted cataract surgery in eyes with foldable anterior or posterior chamber phakic intraocular lenses
    Kohnen, Thomas
    Steinwender, Gernot
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (02) : 124 - 128
  • [6] Vault changes after cyclopentolate instillation in eyes with posterior chamber phakic intraocular lens
    Gargallo-Martinez, Beatriz
    Javier Garcia-Medina, Jose
    Rubio-Velazquez, Elena
    Fernandes, Paulo
    Villa-Collar, Cesar
    Gonzalez-Meijome, Jose M.
    Gutierrez-Ortega, Ramon
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [7] Changes of ocular biometry in eyes with posterior chamber phakic intraocular lens implantation
    Kayhan, B.
    Coskunseven, E.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2022, 45 (04): : 377 - 383
  • [8] Collagen copolymer toric posterior chamber phakic intraocular lens in eyes with keratoconus
    Alfonso, Jose F.
    Fernandez-Vega, Luis
    Lisa, Carlos
    Fernandes, Paulo
    Gonzalez-Meijome, Jose M.
    Montes-Mico, Robert
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (06) : 906 - 916
  • [9] Collagen copolymer toric posterior chamber phakic intraocular lenses to correct high myopic astigmatism
    Alfonso, Jose F.
    Baamonde, Begona
    Madrid-Costa, David
    Fernandes, Paulo
    Jorge, Jorge
    Montes-Mico, Robert
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (08) : 1349 - 1357
  • [10] Etiology and outcomes of current posterior chamber phakic intraocular lens extraction
    Hayakawa, Hideki
    Kamiya, Kazutaka
    Ando, Wakako
    Takahashi, Masahide
    Shoji, Nobuyuki
    SCIENTIFIC REPORTS, 2020, 10 (01)