Real-World Low-Dose CT Image Denoising by Patch Similarity Purification

被引:0
|
作者
Song, Zeya [1 ]
Xue, Liqi [1 ]
Xu, Jun [1 ,2 ]
Zhang, Baoping [3 ,4 ,5 ]
Jin, Chao [3 ,4 ,5 ]
Yang, Jian [3 ,4 ,5 ]
Zou, Changliang [1 ]
机构
[1] Nankai Univ, Sch Stat & Data Sci, Tianjin 300071, Peoples R China
[2] Chinese Univ Hong Kong, Guangdong Prov Key Lab Big Data Comp, Shenzhen 518172, Peoples R China
[3] Xi An Jiao Tong Univ, Affiliated Hosp 1, Dept Radiol, Xian 710061, Peoples R China
[4] Shaanxi Engn Res Ctr Computat Imaging & Med Intell, Xian 710061, Peoples R China
[5] Xian Key Lab Med Computat Imaging, Xian 710061, Peoples R China
基金
中国国家自然科学基金;
关键词
Image denoising; Computed tomography; Noise; Training; Noise reduction; Purification; Transformers; Rabbits; Image edge detection; Training data; Low-dose CT image denoising; deep learning; data purification strategy; radiation dose reduction; GENERATIVE ADVERSARIAL NETWORK; COMPUTED-TOMOGRAPHY; NOISE; CLASSIFICATION; REDUCTION;
D O I
10.1109/TIP.2024.3515878
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Reducing the radiation dose in CT scanning is important to alleviate the damage to the human health in clinical scenes. A promising way is to replace the normal-dose CT (NDCT) imaging by low-dose CT (LDCT) imaging with lower tube voltage and tube current. This often brings severe noise to the LDCT images, which adversely affects the diagnosis accuracy. Most of existing LDCT image denoising networks are trained either with synthetic LDCT images or real-world LDCT and NDCT image pairs with huge spatial misalignment. However, the synthetic noise is very different from the complex noise in real-world LDCT images, while the huge spatial misalignment brings inaccurate predictions of tissue structures in the denoised LDCT images. To well utilize real-world LDCT and NDCT image pairs for LDCT image denoising, in this paper, we introduce a new Patch Similarity Purification (PSP) strategy to construct high-quality training dataset for network training. Specifically, our PSP strategy first perform binarization for each pair of image patches cropped from the corresponding LDCT and NDCT image pairs. For each pair of binary masks, it then computes their similarity ratio by common mask calculation, and the patch pair can be selected as a training sample if their mask similarity ratio is higher than a threshold. By using our PSP strategy, each training set of our Rabbit and Patient datasets contain hundreds of thousands of real-world LDCT and NDCT image patch pairs with negligible misalignment. Extensive experiments demonstrate the usefulness of our PSP strategy on purifying the training data and the effectiveness of training LDCT image denoising networks on our datasets. The code and dataset are provided at https://github.com/TuTusong/PSP.
引用
收藏
页码:196 / 208
页数:13
相关论文
共 50 条
  • [1] Zero-Shot Low-Dose CT Image Denoising via Patch-Based Content-Guided Diffusion Models
    Su, Bo
    Hu, Xiangyun
    Zha, Yunfei
    Wu, Zijun
    Ma, Yuncheng
    Xu, Jiabo
    Zhang, Baochang
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2025, 74
  • [2] Cross-Domain Low-Dose CT Image Denoising With Semantic Preservation and Noise Alignment
    Huang, Jiaxin
    Chen, Kecheng
    Ren, Yazhou
    Sun, Jiayu
    Pu, Xiaorong
    Zhu, Ce
    IEEE TRANSACTIONS ON MULTIMEDIA, 2024, 26 : 8771 - 8782
  • [3] Enabling Predication of the Deep Learning Algorithms for Low-Dose CT Scan Image Denoising Models: A Systematic Literature Review
    Zubair, Muhammad
    Md Rais, Helmi B.
    Ullah, Fasee
    Al-Tashi, Qasem
    Faheem, Muhammad
    Ahmad Khan, Arfat
    IEEE ACCESS, 2024, 12 : 79025 - 79050
  • [4] Scale-Sensitive Generative Adversarial Network for Low-Dose CT Image Denoising
    Wang, Yanling
    Han, Zefang
    Zhang, Xiong
    Shangguan, Hong
    Zhang, Pengcheng
    Li, Jie
    Xiao, Ning
    IEEE ACCESS, 2024, 12 : 98693 - 98706
  • [5] SDCNN: Self-Supervised Disentangled Convolutional Neural Network for Low-Dose CT Denoising
    Liu, Yuhang
    Shu, Huazhong
    Chi, Qiang
    Zhang, Yue
    Liu, Zidong
    Wu, Fuzhi
    Coatrieux, Jean-Louis
    Liu, Yi
    Wang, Lei
    Zhang, Pengcheng
    Gui, Zhiguo
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2025, 74
  • [6] Emulating Low-Dose PCCT Image Pairs With Independent Noise for Self-Supervised Spectral Image Denoising
    Wang, Sen
    Yang, Yirong
    Stevens, Grant M.
    Yin, Zhye
    Wang, Adam S.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2025, 44 (01) : 530 - 542
  • [7] A Novel Attention-Guided Enhanced U-Net With Hybrid Edge-Preserving Structural Loss for Low-Dose CT Image Denoising
    Zubair, Muhammad
    Md Rais, Helmi
    Alazemi, Talal
    IEEE ACCESS, 2025, 13 : 6909 - 6923
  • [8] AdaIN-Based Tunable CycleGAN for Efficient Unsupervised Low-Dose CT Denoising
    Gu, Jawook
    Ye, Jong Chul
    IEEE TRANSACTIONS ON COMPUTATIONAL IMAGING, 2021, 7 : 73 - 85
  • [9] Separation-based model for low-dose CT image denoising
    Chen, Wenbin
    Bai, Junjie
    Gu, Xiaohua
    Li, Yuyan
    Shao, Yanling
    Zhang, Quan
    Liu, Yi
    Liu, Yanli
    Gui, Zhiguo
    JOURNAL OF ENGINEERING-JOE, 2020, 2020 (12): : 1198 - 1208
  • [10] A Novel Total Variation Model for Low-Dose CT Image Denoising
    Chen, Wenbin
    Shao, Yanling
    Wang, Yanling
    Zhang, Quan
    Liu, Yi
    Yao, Linhong
    Chen, Yan
    Yang, Guanru
    Gui, Zhiguo
    IEEE ACCESS, 2018, 6 : 78892 - 78903