Comparative Evaluation of Consumer Wearable Devices for Atrial Fibrillation Detection: Validation Study

被引:0
作者
Wouters, Femke [1 ,2 ]
Gruwez, Henri [1 ,2 ,3 ,4 ]
Smeets, Christophe [1 ,2 ]
Pijalovic, Anessa [2 ]
Wilms, Wouter [2 ]
Vranken, Julie [1 ,2 ]
Pieters, Zoe [5 ]
Van Herendael, Hugo [3 ]
Nuyens, Dieter [3 ]
Rivero-Ayerza, Maximo [3 ]
Vandervoort, Pieter [1 ,2 ,3 ]
Haemers, Peter [4 ]
Pison, Laurent [1 ,3 ]
机构
[1] Hasselt Univ, Fac Med & Life Sci, Limburg Clin Res Ctr, Mobile Hlth Unit, Martelarenlaan 42, B-3500 Hasselt, Belgium
[2] Ziekenhuis Oost Limburg, Dept Future Hlth, Genk, Belgium
[3] Ziekenhuis Oost Limburg, Dept Cardiol, Genk, Belgium
[4] Katholieke Univ Leuven, Dept Cardiovasc Sci, Leuven, Belgium
[5] Hasselt Univ, Data Sci Inst, Hasselt, Belgium
关键词
atrial fibrillation; AF; mobile health; photoplethysmography; electrocardiography; smartphone; consumer wearable device; wearable devices; detection; electrocardiogram; ECG; mHealth; RISK-FACTOR; STROKE; SMARTWATCH; ECG;
D O I
10.2196/65139
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: Consumer-oriented wearable devices (CWDs) such as smartphones and smartwatches have gained prominence for their ability to detect atrial fibrillation (AF) through proprietary algorithms using electrocardiography or photoplethysmography (PPG)-based digital recordings. Despite numerous individual validation studies, a direct comparison of interdevice performance is lacking. Objective: This study aimed to evaluate and compare the ability of CWDs to distinguish between sinus rhythm and AF. Methods: Patients exhibiting sinus rhythm or AF were enrolled through a cardiology outpatient clinic. The participants were instructed to perform heart rhythm measurements using a handheld 6-lead electrocardiogram (ECG) device (KardiaMobile 6L), a smartwatch-derived single-lead ECG (Apple Watch), and two PPG-based smartphone apps (FibriCheck and Preventicus) in a random sequence, with simultaneous 12-lead reference ECG as the gold standard. Results: A total of 122 participants were included in the study: median age 69 (IQR 61-77) years, 63.9% (n=78) men, 25% (n=30) with AF, 9.8% (n=12) without prior smartphone experience, and 73% (n=89) without experience in using a smartwatch. The sensitivity to detect AF was 100% for all devices. The specificity to detect sinus rhythm was 96.4% (95% CI 89.5%-98.8%) for KardiaMobile 6L, 97.8% (95% CI 91.6%-99.5%) for Apple Watch, 98.9% (95% CI 92.5%-99.8%) for FibriCheck, and 97.8% (95% CI 91.5%-99.4%) for Preventicus (P=.50). Insufficient quality measurements were observed in 10.7% (95% CI 6.3%-17.5%) of cases for both KardiaMobile 6L and Apple Watch, 7.4% (95% CI 3.9%-13.6%) for FibriCheck, and 14.8% (95% CI 9.5%-22.2%) for Preventicus (P=.21). Participants preferred Apple Watch over the other devices to monitor their heart rhythm. Conclusions: In this study population, the discrimination between sinus rhythm and AF using CWDs based on ECG or PPG was highly accurate, with no significant variations in performance across the examined devices. Trial Registration: ClinicalTrials.gov NCT06023290; https://clinicaltrials.gov/study/NCT06023290
引用
收藏
页数:11
相关论文
共 28 条
  • [1] Photoplethysmography and its application in clinical physiological measurement
    Allen, John
    [J]. PHYSIOLOGICAL MEASUREMENT, 2007, 28 (03) : R1 - R39
  • [2] Mobile Health for Arrhythmia Diagnosis and Management
    Baman, Jayson R.
    Mathew, Daniel T.
    Jiang, Michael
    Passman, Rod S.
    [J]. JOURNAL OF GENERAL INTERNAL MEDICINE, 2022, 37 (01) : 188 - 197
  • [3] Mobile health technology in atrial fibrillation
    Bonini, Niccolo
    Vitolo, Marco
    Imberti, Jacopo Francesco
    Proietti, Marco
    Romiti, Giulio Francesco
    Boriani, Giuseppe
    Paaske Johnsen, Soren
    Guo, Yutao
    Lip, Gregory Y. H.
    [J]. EXPERT REVIEW OF MEDICAL DEVICES, 2022, 19 (04) : 327 - 340
  • [4] Epidemiology and natural history of atrial fibrillation: Clinical implications
    Chugh, SS
    Blackshear, JL
    Shen, WK
    Hammill, SC
    Gersh, BJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 371 - 378
  • [5] Wearables in cardiology: Here to stay
    Dagher, Lilas
    Shi, Hanyuan
    Zhao, Yan
    Marrouche, Nassir F.
    [J]. HEART RHYTHM, 2020, 17 (05) : 889 - 895
  • [6] Validation of a novel smartphone-based photoplethysmographic method for ambulatory heart rhythm diagnostics: the SMARTBEATS study
    Fernstad, Jonatan
    Svennberg, Emma
    Aberg, Peter
    Kemp Gudmundsdottir, Katrin
    Jansson, Anders
    Engdahl, Johan
    [J]. EUROPACE, 2024, 26 (04):
  • [7] Smartphone detection of atrial fibrillation using photoplethysmography: a systematic review and meta-analysis
    Gill, Simrat
    Bunting, Karina, V
    Sartini, Claudio
    Cardoso, Victor Roth
    Ghoreishi, Narges
    Uh, Hae-Won
    Williams, John A.
    Suzart-Woischnik, Kiliana
    Banerjee, Amitava
    Asselbergs, Folkert W.
    Eijkemans, Mjc
    Gkoutos, Georgios, V
    Kotecha, Dipak
    [J]. HEART, 2022, 108 (20) : 1600 - 1607
  • [8] Real-world validation of smartphone-based photoplethysmography for rate and rhythm monitoring in atrial fibrillation
    Gruwez, Henri
    Ezzat, Daniel
    Van Puyvelde, Tim
    Dhont, Sebastiaan
    Meekers, Evelyne
    Bruckers, Liesbeth
    Wouters, Femke
    Kellens, Michiel
    Van Herendael, Hugo
    Rivero-Ayerza, Maximo
    Nuyens, Dieter
    Haemers, Peter
    Pison, Laurent
    [J]. EUROPACE, 2024, 26 (04):
  • [9] Accuracy of Physicians Interpreting Photoplethysmography and Electrocardiography Tracings to Detect Atrial Fibrillation: INTERPRET-AF
    Gruwez, Henri
    Evens, Stijn
    Proesmans, Tine
    Duncker, David
    Linz, Dominik
    Heidbuchel, Hein
    Manninger, Martin
    Vandervoort, Pieter
    Haemers, Peter
    Pison, Laurent
    [J]. FRONTIERS IN CARDIOVASCULAR MEDICINE, 2021, 8
  • [10] 2020 ESC Guidelines for the diagnosis and management of atrial fibrillation developed in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS): The Task Force for the diagnosis and management of atrial fibrillation of the European Society of Cardiology (ESC) Developed with the special contribution of the European Heart Rhythm Association (EHRA) of the ESC (vol 42, pg 373, 2021)
    Hindricks, Gerhard
    Potpara, Tatjana
    Dagres, Nikolaos
    Arbelo, Elena
    Bax, Jeroen J.
    Blomstroem-Lundqvist, Carina
    Boriani, Giuseppe
    Castella, Manuel
    Dan, Gheorghe-Andrei
    Dilaveris, Polychronis E.
    Fauchier, Laurent
    Filippatos, Gerasimos
    Kalman, Jonathan M.
    La Meir, Mark
    Lane, Deirdre A.
    Lebeau, Jean-Pierre
    Lettino, Maddalena
    Lip, Gregory Y. H.
    Pinto, Fausto J.
    Thomas, G. Neil
    Valgimigli, Marco
    Van Gelder, Isabelle C.
    Van Putte, Bart P.
    Watkins, Caroline L.
    [J]. EUROPEAN HEART JOURNAL, 2021, 42 (40) : 4194 - 4194