Acoustic Radiation Force Optical Coherence Elastography of the Crystalline Lens: Safety

被引:0
作者
Zevallos-Delgado, Christian [1 ]
Mekonnen, Taye Tolu [1 ]
Duvvuri, Chaitanya [2 ]
Rohman, Leana [3 ,4 ]
Schumacher, Justin [5 ]
Singh, Manmohan [1 ]
Aglyamov, Salavat R. [6 ]
Twa, Michael D. [2 ]
Parel, Jean-Marie [3 ,4 ]
Scarcelli, Giuliano [5 ]
Manns, Fabrice [3 ,4 ]
Larin, Kirill V. [1 ]
机构
[1] Univ Houston, Dept Biomed Engn, 2517 Cullen Blvd,Room 2027, Houston, TX 77204 USA
[2] Univ Houston, Coll Optometry, Houston, TX USA
[3] Univ Miami, Bascom Palmer Eye Inst, Ophtalm Biophys Ctr, Miller Sch Med, Miami, FL USA
[4] UNIV MIAMI, COLL ENGN, Dept Biomed Engn, MIAMI, FL USA
[5] Univ Maryland, Bioengn Brain & Behav Inst, Fischell Dept, College Pk, MD USA
[6] Univ Houston, Dept Mech Engn, Houston, TX USA
来源
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY | 2024年 / 13卷 / 12期
基金
美国国家卫生研究院;
关键词
crystalline lens; acoustic radiation force; safety; optical coherence elastography; PROBE;
D O I
10.1167/tvst.13.12.36
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the safety of acoustic radiation force optical coherence elastography in the crystalline lens in situ. Methods: Acoustic radiation force (ARF) produced by an immersion single-element ultrasound transducer (nominal frequency = 3.5 MHz) was characterized using a needle hydrophone and used for optical coherence elastography (OCE) of the crystalline lens. Preamplified signals at 50, 100, 250, 500, 750, 1000, and 1250 mV peak amplitude were tested on ex vivo porcine eyes (n = 21). Three-dimensional optical coherence tomography (OCT) and confocal microscopy images were acquired before and after ARF exposure to each signal amplitude to determine damage. Results: The acoustic intensity of the ultrasound transducer at 100-mV preamplified peak amplitude input demonstrated a signal-to-noise ratio high enough for tracking elastic wave propagation in the lens and spatial-peak pulse-average (SPPA) intensity of 24.1 W/cm(2) and mechanical index (MI) of 0.46. The SPPA intensity was lower than the U.S. Food and Drug Administration (FDA) safety limit (28 W/cm(2)), but the MI was twice the safety limit (0.23). OCT structural and confocal microscopy images showed damage only at levels exceeding 1150 W/cm(2) and 3.2 for SPPA intensity and MI, respectively. Conclusions: OCT and confocal microscopy showed that, even when the intensity exceeded FDA recommendations (>100 mV), no noticeable damage was observed. Although a further reduction in acoustic intensity is necessary to meet FDA safety limits, ARF-based elastography shows promise for safe clinical translation in quantitatively characterizing lenticular biomechanical properties. Translational Relevance: This work assessed the safety standards for acoustic radiation force to be used in human lens elastography according to the FDA safety limits.
引用
收藏
页数:9
相关论文
共 39 条
  • [11] Schmitt J., OCT elastography: imaging microscopic deformation and strain of tissue, Opt Express, 3, pp. 199-211, (1998)
  • [12] Wang RK, Nuttall AL., Phase-sensitive optical coherence tomography imaging of the tissue motion within the organ of Corti at a sub-nanometer scale: a preliminary study, J Biomed Opt, 15, (2010)
  • [13] Huang D, Swanson EA, Lin CP, Et al., Optical coherence tomography, Science, 254, pp. 1178-1181, (1991)
  • [14] Mekonnen T, Zevallos-Delgado C, Zhang H, Singh M, Aglyamov SR, Larin KV., The lens capsule significantly affects the viscoelastic properties of the lens as quantified by optical coherence elastography, Front Bioeng Biotechnol, 11, (2023)
  • [15] Mekonnen T, Zevallos-Delgado C, Singh M, Aglyamov SR, Larin KV., Multifocal acoustic radiation force-based reverberant optical coherence elastography for evaluation of ocular globe biomechanical properties, J Biomed Opt, 28, (2023)
  • [16] Wu C, Aglyamov S, Zhang H, Larin KV., Measur-ing the elastic wave velocity in the lens of the eye as a function of intraocular pressure using optical coherent elastography, Quantum Elec, 49, (2019)
  • [17] Zevallos-Delgado C, Mekonnen T, Zvietcovich F, Singh M, Aglyamov S, Larin K., Assessing porcine iris elasticity and mechanical anisotropy with optical coherence elastography, J Biomed Photonics Eng, 7, (2021)
  • [18] Qu Y, He Y, Saidi A, Et al., In vivo elasticity map-ping of posterior ocular layers using acoustic radiation force optical coherence elastography, Invest Ophthalmol Vis Sci, 59, pp. 455-461, (2018)
  • [19] Kirby MA, Pelivanov I, Song S, Et al., Optical coherence elastography in ophthalmology, J Biomed Opt, 22, pp. 1-28, (2017)
  • [20] Petrella L, Fernandes P, Santos M, Et al., Safety assessment of an A-scan ultrasonic system for ophthalmic use, J Ultrasound Med, 39, pp. 2143-2150, (2020)