Acoustic Radiation Force Optical Coherence Elastography of the Crystalline Lens: Safety

被引:0
作者
Zevallos-Delgado, Christian [1 ]
Mekonnen, Taye Tolu [1 ]
Duvvuri, Chaitanya [2 ]
Rohman, Leana [3 ,4 ]
Schumacher, Justin [5 ]
Singh, Manmohan [1 ]
Aglyamov, Salavat R. [6 ]
Twa, Michael D. [2 ]
Parel, Jean-Marie [3 ,4 ]
Scarcelli, Giuliano [5 ]
Manns, Fabrice [3 ,4 ]
Larin, Kirill V. [1 ]
机构
[1] Univ Houston, Dept Biomed Engn, 2517 Cullen Blvd,Room 2027, Houston, TX 77204 USA
[2] Univ Houston, Coll Optometry, Houston, TX USA
[3] Univ Miami, Bascom Palmer Eye Inst, Ophtalm Biophys Ctr, Miller Sch Med, Miami, FL USA
[4] UNIV MIAMI, COLL ENGN, Dept Biomed Engn, MIAMI, FL USA
[5] Univ Maryland, Bioengn Brain & Behav Inst, Fischell Dept, College Pk, MD USA
[6] Univ Houston, Dept Mech Engn, Houston, TX USA
来源
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY | 2024年 / 13卷 / 12期
基金
美国国家卫生研究院;
关键词
crystalline lens; acoustic radiation force; safety; optical coherence elastography; PROBE;
D O I
10.1167/tvst.13.12.36
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the safety of acoustic radiation force optical coherence elastography in the crystalline lens in situ. Methods: Acoustic radiation force (ARF) produced by an immersion single-element ultrasound transducer (nominal frequency = 3.5 MHz) was characterized using a needle hydrophone and used for optical coherence elastography (OCE) of the crystalline lens. Preamplified signals at 50, 100, 250, 500, 750, 1000, and 1250 mV peak amplitude were tested on ex vivo porcine eyes (n = 21). Three-dimensional optical coherence tomography (OCT) and confocal microscopy images were acquired before and after ARF exposure to each signal amplitude to determine damage. Results: The acoustic intensity of the ultrasound transducer at 100-mV preamplified peak amplitude input demonstrated a signal-to-noise ratio high enough for tracking elastic wave propagation in the lens and spatial-peak pulse-average (SPPA) intensity of 24.1 W/cm(2) and mechanical index (MI) of 0.46. The SPPA intensity was lower than the U.S. Food and Drug Administration (FDA) safety limit (28 W/cm(2)), but the MI was twice the safety limit (0.23). OCT structural and confocal microscopy images showed damage only at levels exceeding 1150 W/cm(2) and 3.2 for SPPA intensity and MI, respectively. Conclusions: OCT and confocal microscopy showed that, even when the intensity exceeded FDA recommendations (>100 mV), no noticeable damage was observed. Although a further reduction in acoustic intensity is necessary to meet FDA safety limits, ARF-based elastography shows promise for safe clinical translation in quantitatively characterizing lenticular biomechanical properties. Translational Relevance: This work assessed the safety standards for acoustic radiation force to be used in human lens elastography according to the FDA safety limits.
引用
收藏
页数:9
相关论文
共 39 条
  • [1] Liu Z, Huang S, Zheng Y, Et al., The lens epithelium as a major determinant in the development, main-tenance, and regeneration of the crystalline lens, Prog Retin Eye Res, 92, (2023)
  • [2] Roskamp KW, Paulson CN, Brubaker WD, Mar-tin RW., Function and aggregation in structural eye lens crystallins, Acc Chem Res, 53, pp. 863-874, (2020)
  • [3] Wagner S, Zrenner E, Strasser T., Emmetropes and myopes differ little in their accommodation dynamics but strongly in their ciliary muscle mor-phology, Vision Res, 163, pp. 42-51, (2019)
  • [4] Rohman L, Ruggeri M, Ho A, Parel JM, Manns F., Lens thickness microfluctuations in young and prepresbyopic adults during steady-state accom-modation, Invest Ophthalmol Vis Sci, 64, (2023)
  • [5] Zhang H, Singh M, Zvietcovich F, Larin K, Aglyamov S., Age-related changes in the viscoelas-ticity of rabbit lens characterised by surface wave dispersion analysis, Quantum Elec, 52, (2022)
  • [6] Park S, Yoon H, Larin KV, Emelianov SY, Aglyamov SR., The impact of intraocular pressure on elastic wave velocity estimates in the crystalline lens, Phys Med Biol, 62, pp. N45-N57, (2017)
  • [7] Katz JA, Karpecki PM, Dorca A, Et al., Presbyopia-a review of current treatment options and emerg-ing therapies, Clin Ophthalmol, 15, pp. 2167-2178, (2021)
  • [8] Ambekar YS, Singh M, Zhang J, Et al., Mul-timodal quantitative optical elastography of the crystalline lens with optical coherence elastography and Brillouin microscopy, Biomed Opt Express, 11, pp. 2041-2051, (2020)
  • [9] Scarcelli G, Kim P, Yun SH., In vivo measure-ment of age-related stiffening in the crystalline lens by Brillouin optical microscopy, Biophys J, 101, pp. 1539-1545, (2011)
  • [10] Zhang H, Wu C, Singh M, Nair A, Aglyamov S, Larin K., Optical coherence elastography of cold cataract in porcine lens, J Biomed Opt, 24, pp. 1-7, (2019)