Multi-institutional study on image quality for a novel CBCT solution on O-ring linac

被引:0
作者
Agulles-Pedros, Luis [1 ,2 ]
Macdonald, R. Lee [2 ]
Cherpak, Amanda Jean [2 ]
Dixit, Nayha [3 ]
Dong, Lei [4 ]
Zhao, Tianyu [5 ]
Thind, Kundan [6 ]
Doemer, Anthony [6 ]
Teo, Boon-Keng [4 ]
Su, Shiqin [7 ]
Moncion, Alexander [8 ]
Robar, James L. [2 ]
机构
[1] Univ Nacl Colombia, Dept Med Phys, Phys Dept, Nova Scotia Hlth Author, 5820 Univ Ave, Halifax, NS B3K 6R8, Canada
[2] Nova Scotia Hlth, Dept Med Phys, 5820 Univ St, Halifax, NS B3H1V7, Canada
[3] Varian Adv Oncol Solut, Phys Clin Operat, Palo Alto, CA USA
[4] Univ Penn, Dept Radiat Oncol, Philadelphia, PA USA
[5] Univ S Florida, Radiat Oncol, Tampa, FL USA
[6] Henry Ford Hlth, Radiat Oncol, Detroit, MI USA
[7] Univ Texas MD Anderson Canc Ctr, Radiat Phys, Houston, TX USA
[8] Univ Michigan, Dept Radiat Oncol, Ann Arbor, MI USA
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2025年
关键词
CBCT; image analysis; image quality; new technology; phantom image; BEAM COMPUTED-TOMOGRAPHY; CT; NUMBER;
D O I
10.1002/acm2.70023
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: This work presents a multi-institutional study on image quality provided by a novel cone beam computed tomography (CBCT). The main goal is to investigate the consistency of imaging performance across multiple institutions. Methods: Phantoms for measuring relative electron density (RED) and image quality were sent to six institutions for imaging on Ethos and Halcyon units equipped with HyperSight CBCT. The imaging protocols included tube potential from 100 to 140 kVp and exposure from 80 to 800 mAs. Imaging performance was evaluated with regard to RED versus Hounsfield units (HU), uniformity, contrast-to-noise ratio (CNR), slice thickness, circular symmetry, modulation transfer function (MTF), and spatial resolution. Results: Among all institutions, some variability was observed among institutions in the RED-to-HU relationship, especially for RED values greater than 1, although no outliers were found (|z-score| < 2 in all cases). In this range, RED/HU slopes were 475 +/- 25 10(-6) RED/HU at 100kVp, 505 +/- 20 10(-6) RED/HU at 125kVp, and 550 +/- 20 10(-6) RED/HU at 140kVp. Radial uniformity ranged from 1 to 7 HU, depending on protocol. Circular symmetry for two points 50 mm apart showed consistency within one-pixel dimension. Integral nonuniformity was between 1 and 10, with no difference observed between vertical and horizontal dimensions. Contrast rods with 1% gave CNR = 0.5, 1 and 2 for 100(88), 125(176), and 140(528) in kVp(mAs), and contrast rods with 0.5% had CNR = 0.2, 0.4 and 0.8 for 100(88), 125(176), and 140(528) in kVp(mAs). Spatial resolution given by MTF at 10% and 50% yielded values of 0.55 +/- 0.01 mm(-1) and 0.35 +/- 0.02 mm(-1), respectively. Conclusions: This multi-institutional analysis of CBCT imaging performance showed consistency in radial uniformity, circular symmetry, integral nonuniformity, contrast, and spatial resolution. Some variability was seen in the RED-to-HU relationship for RED > 1 depending on exposure. More data from different institutions would be necessary to establish more robust statistical metrics, which ensure quality parameters.
引用
收藏
页数:13
相关论文
共 39 条
  • [1] AgullesPedrs L., 2024, AAPM 2024 Annual Meeting Abstract ID 9708
  • [2] Alsleem HA., 2020, Med Sci (Basel), V8
  • [3] AUTOMATIC MEASUREMENT OF CT NUMBER LINEARITY IN THREE TYPES OF CATPHAN PHANTOMS
    Anam, Choirul
    Amilia, Riska
    Naufal, Ariij
    Dougherty, Geoff
    [J]. JURNAL TEKNOLOGI-SCIENCES & ENGINEERING, 2023, 85 (06): : 155 - 160
  • [4] Automated MTF measurement in CT images with a simple wire phantom
    Anam, Choirul
    Fujibuchi, Toshioh
    Haryanto, Freddy
    Budi, Wahyu Setia
    Sutanto, Heri
    Adi, Kusworo
    Muhlisin, Zaenul
    Dougherty, Geoff
    [J]. POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2019, 25 (03): : 179 - 187
  • [5] Adaptive radiation therapy: When, how and what are the benefits that literature provides?
    Avgousti, R.
    Antypas, C.
    Armpilia, C.
    Simopoulou, F.
    Karaiskos, P.
    Liakouli, Z.
    Kouloulias, V.
    Kyrodimos, E.
    Moulopoulos, L. A.
    Zygogianni, A.
    [J]. CANCER RADIOTHERAPIE, 2022, 26 (04): : 622 - 636
  • [6] Quality assurance for image-guided radiation therapy utilizing CT-based technologies: A report of the AAPM TG-179
    Bissonnette, Jean-Pierre
    Balter, Peter A.
    Dong, Lei
    Langen, Katja M.
    Lovelock, D. Michael
    Miften, Moyed
    Moseley, Douglas J.
    Pouliot, Jean
    Sonke, Jan-Jakob
    Yoo, Sua
    [J]. MEDICAL PHYSICS, 2012, 39 (04) : 1946 - 1963
  • [7] Evaluation of a cone-beam computed tomography system calibrated for accurate radiotherapy dose calculation
    Bogowicz, Marta
    Lustermans, Didier
    Taasti, Vicki Trier
    Hazelaar, Colien
    Verhaegen, Frank
    Fonseca, Gabriel Paiva
    van Elmpt, Wouter
    [J]. PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 29
  • [8] Can different Catphan phantoms be used in a multi-centre audit of radiotherapy CT image quality?
    Davis, Anne T.
    Palmer, Antony L.
    Nisbet, Andrew
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 78 : 38 - 47
  • [9] A study on image quality provided by a kilovoltage cone-beam computed tomography
    Garayoa, Julia
    Castro, Pablo
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (01): : 239 - 257
  • [10] ACR benchmark testing of a novel high-speed ring-gantry linac kV-CBCT system
    Haertter, Allison
    Salerno, Michael
    Koger, Brandon
    Kennedy, Christopher
    Alonso-Basanta, Michelle
    Dong, Lei
    Teo, Boon-Keng
    Li, Taoran
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (05):