A Randomized Controlled Trial Comparing STREAMLINE Canaloplasty to Trabecular Micro-Bypass Stent Implantation in Primary Open-Angle Glaucoma

被引:0
|
作者
Goldberg, Damien F. [1 ]
Orlich, Claudio [2 ]
Flowers, Brian E. [3 ]
Singh, Inder P. [4 ]
Tyson, Sydney [5 ]
Seibold, Leonard K. [6 ]
ElMallah, Mohammed K. [7 ]
Ison, Elysia M. [8 ]
Harbin, Med [8 ]
Reynolds, Heather [8 ]
Kahook, Malik Y. [9 ]
机构
[1] Wolstan & Goldberg Eye Associates, Torrance, CA USA
[2] Clin 20-20, San Jose, Costa Rica
[3] Ophthalmol Associates, Ft Worth, TX USA
[4] Eye Ctr Racine & Kenosha, Racine, WI USA
[5] Eye Associates & SurgiCenter Vineland, Vineland, NJ USA
[6] Univ Colorado, Eye Ctr, Dept Ophthalmol, Aurora, CO USA
[7] Ocala Eye, Ocala, FL USA
[8] New World Med, Rancho Cucamonga, CA USA
[9] Univ Colorado, Dept Ophthalmol, Anschutz Med Campus, Aurora, CO 80309 USA
来源
CLINICAL OPHTHALMOLOGY | 2024年 / 18卷
关键词
primary open-angle glaucoma; POAG; STREAMLINE; iStent inject W; canaloplasty; microinvasive glaucoma surgery; MIGS; KAHOOK DUAL BLADE; EXCISIONAL GONIOTOMY; INTRAOCULAR-PRESSURE; PHACOEMULSIFICATION; SURGERY;
D O I
10.2147/OPTH.S481945
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To report interim results of the VENICE study, a multi-center, randomized, controlled trial (RCT) comparing STREAMLINE Surgical System (STREAMLINE) canaloplasty with iStent inject W (iStent W) implantation in patients with mild- to-moderate primary open-angle glaucoma (POAG) undergoing phacoemulsification. Patients and Methods: Safety and efficacy analyses involving the first 72 randomized eyes are included in this report. Following pre- (Screening) and post-medication washout (Eligibility) visits, one eye per subject was randomized 1:1 to STREAMLINE or iStent W after undergoing uncomplicated phacoemulsification. Subjects were evaluated postoperatively at Day 1, Week 1, Month 1, 3, and 6. Intraocular pressure (IOP) measurements, number of IOP-lowering medications, and adverse events (AEs) were assessed at each follow-up visit. Results: Seventy-two eyes were randomized; 35 underwent STREAMLINE canaloplasty and 37 were implanted with the iStent W. Seventy eyes completed their 6-month follow-up. Both the mean morning post-washout Baseline IOP between STREAMLINE 24.86 +/- 3.05 mmHg and iStent W 25.16 +/- 3.41 mmHg and the mean IOP at 6 months between STREAMLINE eyes 16.52 +/- 3.63 mmHg and iStent W eyes 16.08 +/- 3.19 mmHg were not statistically significantly different (p=0.691 and 0.596, respectively). At 6 months, more eyes were on zero glaucoma medications in the STREAMLINE group (81.8%) compared to the iStent W group (78.4%). In medication-free eyes, the mean IOP was reduced from 24.80 +/- 2.79 mmHg to 16.00 +/- 3.40 mmHg and 24.60 +/- 3.18 mmHg to 15.80 +/- 2.21 mmHg in the STREAMLINE and iStent W groups, respectively (p=0.752). Both groups showed reduction in IOP-lowering medications at every visit, compared to pre-washout (Screening), with STREAMLINE resulting in numerically fewer medications 0.20 +/- 0.48 compared to iStent W 0.40 +/- 0.79 at 6 months (P=0.384). AEs were mild and self-limited. Conclusion: To our knowledge, the VENICE trial is the first RCT involving canaloplasty. These interim findings demonstrated comparable IOP and medication reduction between STREAMLINE canaloplasty and iStent W implantation, when combined with phacoemulsification.
引用
收藏
页码:2917 / 2928
页数:12
相关论文
共 50 条
  • [41] Efficacy and Safety of Pairing iStent Inject Trabecular Micro-Bypass and iAccess Precision Blade Goniotomy in Patients with Open-Angle Glaucoma
    Mark J. Gallardo
    Matthew Porter
    Ophthalmology and Therapy, 2023, 12 : 1973 - 1987
  • [42] Intraocular Pressure Fluctuation in Primary Open-Angle Glaucoma with Canaloplasty and Microcatheter Assisted Trabeculotomy
    Xin, Chen
    Wang, Ningli
    Wang, Huaizhou
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (24)
  • [43] Safety and efficacy of iStent Inject trabecular micro-bypass stents in combination with phacoemulsification for chronic open angle glaucoma associated with cataract
    Cela, D.
    Brasnu, E.
    Hamard, P.
    Baudouin, C.
    Labbe, A.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2023, 46 (02): : 129 - 136
  • [44] Excisional goniotomy vs trabecular microbypass stent implantation: a prospective randomized clinical trial in eyes with mild to moderate open-angle glaucoma
    Falkenberry, Suzanne
    Singh, Inder Paul
    Crane, Charles J.
    Haider, Mohammed Ali
    Morgan, Michael G.
    Grenier, Christopher P.
    Brubaker, Jacob W.
    Balasubramani, Goundappa K.
    Dorairaj, Syril
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (08) : 1165 - 1171
  • [45] Implantation of a CyPass Supraciliary Stent Combined With Targeted iStent Trabecular Microbypass Stents in a Phakic Patient With Primary Open-angle Glaucoma
    Chen, Kevin H.
    Kim, Won I.
    JOURNAL OF GLAUCOMA, 2018, 27 (02) : E37 - E39
  • [46] Trabecular microbypass stent implantation in pseudophakic eyes with open-angle glaucoma: Long-term results
    Ferguson, Tanner J.
    Ibach, Mitch
    Schweitzer, Justin
    Karpuk, Kayla
    Stephens, J. David
    Sudhagoni, Ramu
    Berdahl, John P.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (04) : 414 - 420
  • [47] Cost-effectiveness analysis of standalone trabecular micro-bypass stents in patients with mild-to-moderate open-angle glaucoma in Canada
    Patel, Vardhaman
    Ahmed, Ike
    Podbielski, Dominik
    Falvey, Heather
    Murray, Judith
    Goeree, Ron
    JOURNAL OF MEDICAL ECONOMICS, 2019, 22 (04) : 390 - 401
  • [48] Clinical Evaluation of the Aqueous Outflow System in Primary Open-Angle Glaucoma for Canaloplasty
    Grieshaber, Matthias C.
    Pienaar, Ane
    Olivier, Jan
    Stegmann, Robert
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (03) : 1498 - 1504
  • [49] Safety and Efficacy of Two Trabecular Micro-Bypass Stents as the Sole Procedure in Japanese Patients with Medically Uncontrolled Primary Open-Angle Glaucoma: A Pilot Case Series
    Shiba, Daisuke
    Hosoda, Shingo
    Yaguchi, Saori
    Ozeki, Naoki
    Yuki, Kenya
    Tsubota, Kazuo
    JOURNAL OF OPHTHALMOLOGY, 2017, 2017
  • [50] Implantation of trabecular micro-bypass stent using a novel “landing strip” technique
    Cindy X.Zheng
    Marlene R.Moster
    Priyanka Gogte
    Yang Dai
    Remy S.Manzi
    Michael Waisbourd
    International Journal of Ophthalmology, 2017, (05) : 738 - 741