The Impact of Intraoperative Transit-Time Flow Measurement on Off-Pump and On-Pump Bypass Surgery Based on Three Months: A Propensity Score Matching Study

被引:0
作者
Calik, Eyup Serhat [1 ]
Arslan, Umit [1 ]
机构
[1] Ataturk Univ, Dept Cardiovasc Surg, Fac Med, TR-25240 Erzurum, Turkiye
关键词
transit-time flow measurement; coronary artery bypass graft surgery; on-pump; off-pump; GRAFT FAILURE; QUALITY ASSESSMENT; CORONARY; ARTERIAL; OUTCOMES; PATENCY;
D O I
10.59958/hsf.7989
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The goal of this study was to investigate how transit-time flow measurement (TTFM) parameters influenced the success of coronary bypass surgeries using the on-pump coronary artery bypass (ONCAB) and off- pump coronary artery bypass (OPCAB) techniques and to compare the rates of early graft failure and major adverse cardiac and cerebrovascular events (MACCE). Methods: We retrospectively analyzed subjects who underwent coronary bypass surgery at our institution between 2017 and 2023 and compared the TTFM data of patients divided into two groups based on the surgical method: ONCAB and OPCAB. We compared the postoperative and first three months' MACCE data to assess the impact of TTFM on the two surgical methods. Results: Of the 2032 patients who underwent coronary bypass, we analyzed data from 1540 patients in the ONCAB group and 194 patients in the OP- CAB group. After propensity score matching, the TTFM data of 192 patients in both groups were compared. In the ONCAB group, a mean of 3.28 +/- 0.7 grafts per patient was used, while 2.22 +/- 0.6 grafts were used in the OP- CAB group (p = 0.001). TTFM identified problems with 19 (4.7%) grafts in the ONCAB group and 29 (8%) grafts in the OPCAB group, leading to their revision (p = 0.001). Overall, the pulsatile index (PI) values in the OPCAB group were significantly higher than in the ONCAB group. Hospital mortality was 3.1% in the ONCAB group and 2.6% in the OPCAB group (p = 0.286). MACCE and graft failure rates were similar in the first three months. Conclusions: Utilizing TTFM to assess graft quality during surgery enhances coronary bypass surgery in both ONCAB and OPCAB procedures. The enhanced results are particularly crucial for a process like OPCAB surgery, which necessitates the expertise and experience of a surgeon and is challenging to execute.
引用
收藏
页码:E1339 / E1350
页数:12
相关论文
共 48 条
[31]   On-pump versus off-pump coronary artery bypass surgery in high-risk patients: Operative results of a prospective randomized trial (on-off study) [J].
Lemma, Massimo G. ;
Coscioni, Enrico ;
Tritto, Francesco P. ;
Centofanti, Paolo ;
Fondacone, Corrado ;
Salica, Andrea ;
Rossi, Agnese ;
De Santo, Tiziana ;
Di Benedetto, Giuseppe ;
Piazza, Luigi ;
Rinaldi, Mauro ;
Schinosa, Antonio L. De Luca Tupputi ;
De Paulis, Ruggero ;
Contino, Monica ;
Genoni, Michele .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2012, 143 (03) :625-631
[32]   The off-pump technique in redo coronary artery bypass grafting reduces mortality and major morbidities: propensity score analysis of data from the Japan Cardiovascular Surgery Database [J].
Dohi, Masahiro ;
Miyata, Hiroaki ;
Doi, Kiyoshi ;
Okawa, Kazunari ;
Motomura, Noboru ;
Takamoto, Shinichi ;
Yaku, Hitoshi .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2015, 47 (02) :299-308
[33]   Does Early Graft Patency Benefit from Perioperative Statin Therapy? A Propensity Score-Matched Study of Patients Undergoing Off-Pump Coronary Artery Bypass Surgery [J].
Chen, Shanglin ;
Wu, Hengchao ;
Yang, Tao ;
Li, Baotong ;
Hu, Yuanyu ;
Sun, Hansong .
CARDIOVASCULAR THERAPEUTICS, 2019, 2019
[34]   Preserved autoregulation of coronary flow after off-pump coronary artery bypass grafting: retrospective assessment of intraoperative transit time flowmetry with and without intra-aortic balloon counterpulsation [J].
Nakajima, Hiroyuki ;
Iguchi, Atsushi ;
Tabata, Mimiko ;
Kambe, Masaru ;
Ikeda, Masahiro ;
Uwabe, Kazuhiko ;
Asakura, Toshihisa ;
Niinami, Hiroshi .
JOURNAL OF CARDIOTHORACIC SURGERY, 2016, 11
[35]   Impact of the Time of Coronary Angiography on Acute Kidney Injury After Elective Off-Pump Coronary Artery Bypass Surgery [J].
Lee, Eun-Ho ;
Chin, Ji-Hyun ;
Joung, Kyoung-Woon ;
Choi, Dae-Kee ;
Kim, Wook-Jong ;
Lee, Jung-Bok ;
Hahm, Kyung-Don ;
Sim, Ji-Yeon ;
Choi, In-Cheol .
ANNALS OF THORACIC SURGERY, 2013, 96 (05) :1635-1642
[36]   Impact of mild preoperative renal insufficiency on in-hospital and long-term outcomes after off-pump coronary artery bypass grafting: a retrospective propensity score matching analysis [J].
Ji, Qiang ;
Xia, Limin ;
Shi, YunQing ;
Ma, RunHua ;
Wang, ChunSheng ;
Mei, YunQing ;
Ding, WenJun .
JOURNAL OF CARDIOTHORACIC SURGERY, 2016, 11
[37]   Transit time flow measurement predicts graft patency in off-pump coronary artery bypass grafting upon 5-year angiographic follow-up [J].
Caiwu Zeng ;
Xiaomi Li ;
Yan Dai ;
Ye Zhou ;
Chenglong Li ;
Nan Liu ;
Jiangang Wang .
Journal of Cardiothoracic Surgery, 16
[38]   Transit time flow measurement predicts graft patency in off-pump coronary artery bypass grafting upon 5-year angiographic follow-up [J].
Zeng, Caiwu ;
Li, Xiaomi ;
Dai, Yan ;
Zhou, Ye ;
Li, Chenglong ;
Liu, Nan ;
Wang, Jiangang .
JOURNAL OF CARDIOTHORACIC SURGERY, 2021, 16 (01)
[39]   Effect of Preoperatively Continued Aspirin Use on Early and Mid-Term Outcomes in Off-Pump Coronary Bypass Surgery: A Propensity Score-Matched Study of 1418 Patients [J].
Xiao, Fucheng ;
Wu, Hengchao ;
Sun, Hansong ;
Pan, Shiwei ;
Xu, Jianping ;
Song, Yunhu .
PLOS ONE, 2015, 10 (02)
[40]   Preserved autoregulation of coronary flow after off-pump coronary artery bypass grafting: retrospective assessment of intraoperative transit time flowmetry with and without intra-aortic balloon counterpulsation [J].
Hiroyuki Nakajima ;
Atsushi Iguchi ;
Mimiko Tabata ;
Masaru Kambe ;
Masahiro Ikeda ;
Kazuhiko Uwabe ;
Toshihisa Asakura ;
Hiroshi Niinami .
Journal of Cardiothoracic Surgery, 11