Design and Modeling of a Plethysmographic Wearable Sensor for Heart Failure Non-invasive Edema Monitoring

被引:0
|
作者
Maurencig, S. [1 ]
Palmero, M. [1 ]
Algarin, A. [1 ]
Scagliusi, S. F. [1 ,2 ]
Perez, P. [1 ,2 ]
Martin, D. [1 ,4 ]
Huertas, G. [1 ,3 ]
Yufera, A. [1 ,2 ]
机构
[1] Univ Sevilla IMSE US, Inst Microelect Sevilla, Seville, Spain
[2] Univ Seville, Dept Elect Technol, ETSII, Seville, Spain
[3] Univ Seville, Phys Fac, Dept Elect & Electromagnetism, Seville, Spain
[4] Univ Seville, Biol Fac, Dept Cell Biol, Seville, Spain
关键词
Bioimpedance; Biomedical Sensor; Electrodes; Electronics Design; Heart Failure (HF); Plethysmography; Real-time monitoring; Wearable; BIOELECTRICAL-IMPEDANCE ANALYSIS;
D O I
10.1109/BIOSENSORS61405.2024.10712672
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Heart Failure (HF) is a multifaceted syndrome characterized by the heart's inability to effectively pump oxygen- and nutrient-rich blood to meet the body's demands, making it a leading cause of hospitalization among individuals aged 65 and older. With a concerning mortality rate of 50% within the initial 5 years post-diagnosis, there is currently no universally accepted set of diagnostic criteria for HF. Recently, bioimpedance (BI) analysis has emerged as a promising technique for identifying a pivotal symptom: changes in body volume attributable to edema. This study proposes the development of a portable plethysmographic device to conduct real-time tests of leg volume changes in a cost-effective and non-invasive manner. The device looks to enhance at-home patient monitoring, for prompt diagnosis, and it is characterized by its compactness, wearability, wireless functionality, lightweight nature, and energy efficiency. It employs four electrodes for BI test, and data are transmitted via Bluetooth to an Android device for further analysis and monitoring.(1)
引用
收藏
页数:4
相关论文
共 50 条
  • [41] Flexible, Non-invasive, and Wearable Fish Heart Rate Monitoring Tag for Guiding Aquaculture in Marine Ranching
    Zhang, Hai
    Wei, Zihong
    Wu, Diye
    Dai, Zhuhang
    Hughes, Danny
    Sugahara, Tohru
    Izumi, Shintaro
    Yang, Yang
    2024 IEEE SENSORS, 2024,
  • [42] Non-invasive technologies for heart failure, systolic and diastolic dysfunction modeling: a scoping review
    Al Younis, Sona M.
    Hadjileontiadis, Leontios J.
    Stefanini, Cesare
    Khandoker, Ahsan H.
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [43] INVASIVE OR NON-INVASIVE MONITORING
    HUGENHOL.PG
    HEIKKILA, J
    HAGEMEIJ.F
    ARNTZENI.AC
    POOL, J
    PALADINO, D
    CIRCULATION, 1972, 46 (04) : 75 - &
  • [44] Wearable biosensors and biofuel cells for continuous non-invasive epidermal monitoring
    Jia, Wenzhao
    Bandodkar, Amay Jairaj
    Valdes-Ramirez, Gabriela
    Wang, Joseph
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 248
  • [45] In vivo wearable non-invasive glucose monitoring based on dielectric spectroscopy
    Liu, Yuhang
    Xia, Meng
    Nie, Zedong
    Li, Jingzhen
    Zeng, Yicheng
    Wang, Lei
    PROCEEDINGS OF 2016 IEEE 13TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING (ICSP 2016), 2016, : 1388 - 1391
  • [46] Clinical assessment of a non-invasive wearable MEMS pressure sensor array for monitoring of arterial pulse waveform, heart rate and detection of atrial fibrillation
    Matti Kaisti
    Tuukka Panula
    Joni Leppänen
    Risto Punkkinen
    Mojtaba Jafari Tadi
    Tuija Vasankari
    Samuli Jaakkola
    Tuomas Kiviniemi
    Juhani Airaksinen
    Pekka Kostiainen
    Ulf Meriheinä
    Tero Koivisto
    Mikko Pänkäälä
    npj Digital Medicine, 2
  • [47] Clinical assessment of a non-invasive wearable MEMS pressure sensor array for monitoring of arterial pulse waveform, heart rate and detection of atrial fibrillation
    Kaisti, Matti
    Panula, Tuukka
    Leppanen, Joni
    Punkkinen, Risto
    Tadi, Mojtaba Jafari
    Vasankari, Tuija
    Jaakkola, Samuli
    Kiviniemi, Tuomas
    Airaksinen, Juhani
    Kostiainen, Pekka
    Meriheina, Ulf
    Koivisto, Tero
    Pankaala, Mikko
    NPJ DIGITAL MEDICINE, 2019, 2 (1)
  • [48] Microflotronic Arterial Tonometry for Continuous Wearable Non-Invasive Hemodynamic Monitoring
    Philip Digiglio
    Ruya Li
    Wenqi Wang
    Tingrui Pan
    Annals of Biomedical Engineering, 2014, 42 : 2278 - 2288
  • [49] Non-invasive Techniques for Heart Rate Monitoring: A Review
    Naik, Rasika
    Jadhav, Manjiri
    Mahankuda, Puja
    Gupta, Bhoomi
    SMART TRENDS IN COMPUTING AND COMMUNICATIONS, VOL 3, SMARTCOM 2024, 2024, 947 : 263 - 273