Design and Modeling of a Plethysmographic Wearable Sensor for Heart Failure Non-invasive Edema Monitoring

被引:0
|
作者
Maurencig, S. [1 ]
Palmero, M. [1 ]
Algarin, A. [1 ]
Scagliusi, S. F. [1 ,2 ]
Perez, P. [1 ,2 ]
Martin, D. [1 ,4 ]
Huertas, G. [1 ,3 ]
Yufera, A. [1 ,2 ]
机构
[1] Univ Sevilla IMSE US, Inst Microelect Sevilla, Seville, Spain
[2] Univ Seville, Dept Elect Technol, ETSII, Seville, Spain
[3] Univ Seville, Phys Fac, Dept Elect & Electromagnetism, Seville, Spain
[4] Univ Seville, Biol Fac, Dept Cell Biol, Seville, Spain
关键词
Bioimpedance; Biomedical Sensor; Electrodes; Electronics Design; Heart Failure (HF); Plethysmography; Real-time monitoring; Wearable; BIOELECTRICAL-IMPEDANCE ANALYSIS;
D O I
10.1109/BIOSENSORS61405.2024.10712672
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Heart Failure (HF) is a multifaceted syndrome characterized by the heart's inability to effectively pump oxygen- and nutrient-rich blood to meet the body's demands, making it a leading cause of hospitalization among individuals aged 65 and older. With a concerning mortality rate of 50% within the initial 5 years post-diagnosis, there is currently no universally accepted set of diagnostic criteria for HF. Recently, bioimpedance (BI) analysis has emerged as a promising technique for identifying a pivotal symptom: changes in body volume attributable to edema. This study proposes the development of a portable plethysmographic device to conduct real-time tests of leg volume changes in a cost-effective and non-invasive manner. The device looks to enhance at-home patient monitoring, for prompt diagnosis, and it is characterized by its compactness, wearability, wireless functionality, lightweight nature, and energy efficiency. It employs four electrodes for BI test, and data are transmitted via Bluetooth to an Android device for further analysis and monitoring.(1)
引用
收藏
页数:4
相关论文
共 50 条
  • [31] A wearable aptamer nanobiosensor for non-invasive female hormone monitoring
    Cui Ye
    Minqiang Wang
    Jihong Min
    Roland Yingjie Tay
    Heather Lukas
    Juliane R. Sempionatto
    Jiahong Li
    Changhao Xu
    Wei Gao
    Nature Nanotechnology, 2024, 19 : 330 - 337
  • [32] A compact Non-Invasive Wearable Vital Signal Monitoring System
    Wei, Yuan
    Zahid, Adnan
    Heidari, Hadi
    Imran, Muhammad
    Abbasi, Qammer H.
    CONFERENCE PROCEEDINGS OF 2018 IEEE ASIA PACIFIC CONFERENCE ON POSTGRADUATE RESEARCH IN MICROELECTRONICS AND ELECTRONICS (PRIMEASIA 2018), 2018, : 55 - 59
  • [33] Non-Invasive Heart Rate Monitoring System using Giant Magneto Resistance Sensor
    Kalyan, Kubera
    Chugh, Vinit Kumar
    Anoop, C. S.
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 4873 - 4876
  • [34] Cotton thread-based wearable sensor for non-invasive simultaneous diagnosis of diabetes and kidney failure
    Promphet, Nadtinan
    Hinestroza, Juan P.
    Rattanawaleedirojn, Pranee
    Soatthiyanon, Niphaphun
    Siralertmukul, Krisana
    Potiyaraj, Pranut
    Rodthongkum, Nadnudda
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 321
  • [35] Development of a microfluidic wearable electrochemical sensor for the non-invasive monitoring of oxidative stress biomarkers in human sweat
    Ying, Zhiye
    Qiao, Lijuan
    Liu, Bingxin
    Gao, Li
    Zhang, Peng
    BIOSENSORS & BIOELECTRONICS, 2024, 261
  • [36] A Pilot Study of Blood Pressure Monitoring After Cardiac Surgery Using a Wearable, Non-invasive Sensor
    Kachel, Erez
    Constantini, Keren
    Nachman, Dean
    Carasso, Shemy
    Littman, Romi
    Eisenkraft, Arik
    Gepner, Yftach
    FRONTIERS IN MEDICINE, 2021, 8
  • [37] INTEGRATED SENSOR FOR NON-INVASIVE MONITORING OF FLOW IN PIPES
    VANOUDHEUSDEN, BW
    DEBRUIJN, JM
    HOOGEBOOM, PJ
    BEAUFORT, D
    HUIJSING, JH
    SENSORS AND ACTUATORS, 1989, 18 (3-4): : 259 - 267
  • [38] The utility of novel non-invasive technologies for remote hemodynamic monitoring in chronic heart failure
    Mabote, Thato
    Wong, Kenneth
    Cleland, John G. F.
    EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2014, 12 (08) : 923 - 928
  • [39] Non-Invasive Sensor for Grounding Grid Mesh Monitoring
    Souza Medeiros, Felipe Lucena
    Lazaridis, Pavlos
    Rocha Xavier, George Victor
    da Costa, Edson Guedes
    Rene Serres, Alexandre Jean
    2024 IEEE INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION AND INC/USNCURSI RADIO SCIENCE MEETING, AP-S/INC-USNC-URSI 2024, 2024, : 1833 - 1834
  • [40] A SENSOR FOR NON-INVASIVE MONITORING OF CARBON-DIOXIDE
    EBERHARD, P
    SCHAFER, R
    BRITISH JOURNAL OF CLINICAL EQUIPMENT, 1980, 5 (06): : 224 - 226