Unbiased Euclidean Direction Search Algorithm for Partial Discharge Location in Cable Systems

被引:0
作者
Wang, Jie [1 ]
Lu, Lu [1 ]
Zhu, Guangya [2 ]
Yin, Kai-Li [3 ]
Zhou, Kai [2 ]
Chen, Badong [4 ]
机构
[1] Sichuan Univ, Coll Elect & Informat Engn, Chengdu 610065, Peoples R China
[2] Sichuan Univ, Coll Elect Engn, High Voltage Lab, Chengdu 610065, Peoples R China
[3] Qingdao Univ Sci & Technol, Coll Automat & Elect Engn, Qingdao 266520, Peoples R China
[4] Xi An Jiao Tong Univ, Inst Artificial Intelligence & Robot IAIR, Xian 710049, Peoples R China
基金
中国国家自然科学基金;
关键词
Noise measurement; Signal processing algorithms; Noise; Power cables; Cable insulation; Accuracy; Estimation; Cable shielding; Vectors; Transient analysis; Cable systems; location; normalized Euclidean direction search (EDS); partial discharge (PD); transient behavior; TOTAL LEAST-SQUARES; LOCALIZATION; KERNEL;
D O I
10.1109/TIM.2025.3538076
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Utilizing the unbiasedness criterion, this article proposes a bias-compensated normalized Euclidean direction search (BC-NEDS) algorithm with noisy inputs, which can effectively mitigate the impact of the bias by estimating the statistical properties of inputs. Moreover, the theoretical analysis of the BC-NEDS algorithm is conducted in a transient regime. Simulations verify the validity of the theoretical analysis and showcase the improved performance of the BC-NEDS algorithm. Partial discharge (PD) location techniques can be utilized to effectively monitor the condition of the electrical apparatus. Considering the performance of the conventional location algorithms based on the time difference of arrival (TDOA) method may notably degrade with noisy inputs. Hitherto, scarce literature concentrates on the PD location problem by leveraging adaptive filtering techniques. Such problem is essentially characterized by a noisy input model. This work aims to propose a new one-step algorithm to simultaneously denoise and achieve improved location accuracy with noisy input. The BC-NEDS algorithm is employed for solving the PD location problem. The BC-NEDS algorithm demonstrates the effectiveness in mitigating the bias arising from noisy inputs in both the direct and reflected PD signals and estimating the time difference to locate the PD signal of cable systems. Simulations and experimental studies exhibit that the BC-NEDS algorithm verifies the effectiveness and achieves enhanced location accuracy for cable systems.
引用
收藏
页数:13
相关论文
共 27 条
  • [21] Online partial discharge signal conditioning for φ-q-n representation under noisy condition in cable systems
    Shahsavarian, Tohid
    Shahrtash, Seyyed Mohammad
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2015, 9 (01) : 20 - 27
  • [22] Partial discharge localisation methodology for power transformers based on improved acoustic propagation route search algorithm
    Wang, Yan-Bo
    Fan, Yu-Hang
    Qin, Shao-Rui
    Chang, Ding-Ge
    Shao, Xian-Jun
    Mu, Hai-Bao
    Zhang, Guan-Jun
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2018, 12 (08) : 1023 - 1030
  • [23] Automatic partial discharge recognition using the cross wavelet transform in high voltage cable joint measuring systems using two opposite polarity sensors
    Mor, A. Rodrigo
    Munoz, F. A.
    Wu, J.
    Heredia, L. C. Castro
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2020, 117
  • [24] Simultaneous location of two partial discharge sources in power transformers based on acoustic emission using the modified binary partial swarm optimisation algorithm
    Hooshmand, Rahmat Allah
    Parastegari, Moein
    Yazdanpanah, Masoud
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2013, 7 (02) : 119 - 127
  • [25] Optimization scheme of partial discharge location of external insulation based on 2-D multiple signal classification algorithm
    Pei, Shaotong
    Liu, Dewang
    Ye, Zijian
    Yang, Jiajun
    Liu, Yunpeng
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2023, 17 (01) : 11 - 26
  • [26] An Efficient Algorithm for Partial Discharge Localization in High-Voltage Systems Using Received Signal Strength
    Khan, Umar F.
    Lazaridis, Pavlos I.
    Mohamed, Hamd
    Albarracin, Ricardo
    Zaharis, Zaharias D.
    Atkinson, Robert C.
    Tachtatzis, Christos
    Glover, Ian A.
    SENSORS, 2018, 18 (11)
  • [27] Multi-Source Partial Discharge Fault Location with Comprehensive Arrival Time Difference Extraction Method and Multi-Data Dynamic Weighting Algorithm
    Wang, Disheng
    Du, Lin
    Wang, Tao
    Zhao, Xiuna
    ENTROPY, 2023, 25 (04)