Detection of AFB1 by Immunochromatographic Test Strips Based on Double-Probe Signal Amplification with Nanobody and Biotin-Streptavidin System

被引:1
|
作者
Li, Yifan [2 ]
Li, Zhenfeng [3 ]
Jia, Baozhu [4 ]
Tu, Zhui [1 ]
Zeng, Juntao [2 ]
Pang, Jiarui [2 ]
Ren, Wenjie [2 ]
Huang, Zhibing [1 ]
He, Baoshan [2 ]
Wang, Zhihua [2 ]
机构
[1] Nanchang Univ, State Key Lab Food Sci & Technol, Nanchang 330047, Peoples R China
[2] Henan Univ Technol, Natl Engn Res Ctr Wheat & Corn Further Proc, Zhengzhou 450001, Peoples R China
[3] Guangzhou Nabo Antibody Technol Co Ltd, Guangzhou 510530, Peoples R China
[4] Guangdong Univ Educ, Coll Biol & Food Engn, Guangzhou 510303, Peoples R China
关键词
immunochromatographic test strip; AFB(1); nanobody; signal amplification;
D O I
10.3390/foods13213396
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Aflatoxin B-1 (AFB(1)) is highly toxic and difficult to prevent. It is mainly produced by fungi and exists in plants and animals and is classified by the World Health Organization as a class I carcinogen, posing a serious threat to human and animal health. Therefore, it is important to establish an efficient, sensitive, and on-site detection method for AFB1 to protect human health. The immunochromatographic test strip method is simple, sensitive, and can achieve real-time detection. However, traditional immunochromatographic test strips have low sensitivity due to their relatively weak optical properties. In this study, Nb-G8 was biotinylated using a chemical method. Two sizes of gold nanoflowers (AuNFs) were prepared and combined with biotinylated G8 and streptavidin to form two types of probes. These probes were sprayed on gold standard pads and expanded pads, respectively, to enhance the signals through the high affinity interaction between streptavidin and biotin. Under the optimal experimental conditions, the half maximal inhibitory concentration (IC50) of this method was 5.0 ng/mL and the limit of detection (IC10) was 0.03 ng/mL, which increased the sensitivity of the test strip by four-fold compared with that of the traditional biotinylated nanoantibody immunochromatography test strip and had a wider detection range. In conclusion, the use of a high-affinity amplification signal between biotin and streptavidin is a valuable method for the detection of aflatoxin.
引用
收藏
页数:16
相关论文
共 16 条
  • [1] An immediate and antibody protected carboxyl quantum dot immunochromatographic analysis hierarchical signal amplification test strip based on biotin-streptavidin system for the detection of aflatoxin B1 in peanuts
    Yuan, Bei
    Liu, Qiang
    Yang, Qingqing
    Pang, Chengchen
    Xu, Haitao
    Du, Xiaohui
    Wei, Lin
    Nie, Kunying
    Guo, Yemin
    Sun, Xia
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2024, 125
  • [2] Novel dual immunochromatographic test strip based on double antibodies and biotin-streptavidin system for simultaneous sensitive detection of aflatoxin M1 and ochratoxin A in milk
    Sun, Jiadi
    Li, Miao
    Xing, Fuguo
    Wang, Haiming
    Zhang, Yinzhi
    Sun, Xiulan
    FOOD CHEMISTRY, 2022, 375
  • [3] Nanobody-based electrochemical competitive immunosensor for the detection of AFB1 through AFB1-HCR as signal amplifier
    Liu, Xin
    Wen, Yangping
    Wang, Wenjun
    Zhao, Zitong
    Han, Yi
    Tan, Kaijie
    Wang, Dan
    MICROCHIMICA ACTA, 2020, 187 (06)
  • [4] Nanobody-based electrochemical competitive immunosensor for the detection of AFB1 through AFB1-HCR as signal amplifier
    Xin Liu
    Yangping Wen
    Wenjun Wang
    Zitong Zhao
    Yi Han
    Kaijie Tang
    Dan Wang
    Microchimica Acta, 2020, 187
  • [5] Ultrasensitive simultaneous detection of four biomarkers based on hybridization chain reaction and biotin-streptavidin signal amplification strategy
    Zhu, Qiang
    Chai, Yaqin
    Zhuo, Ying
    Yuan, Ruo
    BIOSENSORS & BIOELECTRONICS, 2015, 68 : 42 - 48
  • [6] Optical fiber immunosensor based on graphene oxide and biotin-streptavidin(SA) signal amplification system for rapid and sensitive detection of 17ß-estradiol(E2)
    Guo, Wanmei
    Guo, Qi
    Yu, Hongwen
    Yu, Yongsen
    Jin, Guangyong
    ADVANCED SENSOR SYSTEMS AND APPLICATIONS XII, 2022, 12321
  • [7] Electrochemical immunosensor for N6-methyladenosine detection in human cell lines based on biotin-streptavidin system and silver-SiO2 signal amplification
    Yin, Huanshun
    Wang, Haiyan
    Jiang, Wenjing
    Zhou, Yunlei
    Ai, Shiyun
    BIOSENSORS & BIOELECTRONICS, 2017, 90 : 494 - 500
  • [8] Immunomagnetic bead-based biotin-streptavidin system for highly efficient detection of aflatoxin B1 in agricultural products
    Li, Ming
    Zhang, Yuanyuan
    Zhao, Rujin
    Liu, Zhenjiang
    Hong, Xia
    Cui, Yin
    Xue, Yonglai
    Du, Daolin
    RSC ADVANCES, 2018, 8 (46) : 26029 - 26035
  • [9] Development of two immunochromatographic test strips based on signal amplification and selenium nanoparticles for the rapid detection of T-2 mycotoxin
    Chen, Xianrui
    Gao, Zhipeng
    Long, Tingting
    Xie, Jianhua
    Li, Xiujiang
    Huang, Zhibing
    FOOD CHEMISTRY, 2023, 424
  • [10] A novel Recjf Exo signal amplification strategy based on bioinformatics-assisted truncated aptamer for efficient fluorescence detection of AFB1
    Fan, Yiting
    Amin, Khalid
    Jing, Wendan
    Lyu, Bo
    Wang, Sainan
    Fu, Hongling
    Yu, Hansong
    Yang, Huanhuan
    Li, Jiaxin
    INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2024, 254