Biomimetic Strategies of Slip Sensing, Perception, and Protection in Prosthetic Hand Grasp

被引:0
|
作者
Xie, Anran [1 ]
Zhang, Zhuozhi [1 ]
Zhang, Jie [1 ]
Li, Tie [2 ]
Chen, Weidong [3 ]
Patton, James [4 ]
Lan, Ning [1 ,3 ,4 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Biomed Engn, Shanghai 200030, Peoples R China
[2] Chinese Acad Sci, Suzhou Inst Nanotech & Nanobion, i Lab, Suzhou 215123, Peoples R China
[3] Shanghai Jiao Tong Univ, Inst Med Robot, Dept Automat, Shanghai 200240, Peoples R China
[4] Univ Illinois, Richard & Loan Hill Dept Biomed Engn, Chicago, IL 60607 USA
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
slip sensor; bi-state sensory feedback; biomimetic sensorimotor control; prosthetic hand; slip prevention; PRECISION GRIP; FORCE; RESPONSES; FRICTION; FEEDBACK; MODELS; MUSCLE;
D O I
10.3390/biomimetics9120751
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This study develops biomimetic strategies for slip prevention in prosthetic hand grasps. The biomimetic system is driven by a novel slip sensor, followed by slip perception and preventive control. Here, we show that biologically inspired sensorimotor pathways can be restored between the prosthetic hand and users. A Ruffini endings-like slip sensor is used to detect shear forces and identify slip events directly. The slip information and grip force are encoded into a bi-state sensory coding that evokes vibration and buzz tactile sensations in subjects with transcutaneous electrical nerve stimulation (TENS). Subjects perceive slip events under various conditions based on the vibration sensation and voluntarily adjust grip force to prevent further slipping. Additionally, short-latency compensation for grip force is also implemented using a neuromorphic reflex pathway. The reflex loop includes a sensory neuron and interneurons to adjust the activations of antagonistic muscles reciprocally. The slip prevention system is tested in five able-bodied subjects and two transradial amputees with and without reflex compensation. A psychophysical test for perception reveals that the slip can be detected effectively, with a success accuracy of 96.57%. A slip protection test indicates that reflex compensation yields faster grasp adjustments than voluntary action, with a median response time of 0.30 (0.08) s, a rise time of 0.26 (0.03) s, an execution time of 0.56 (0.07) s, and a slip distance of 0.39 (0.10) cm. Prosthetic grip force is highly correlated to that of an intact hand, with a correlation coefficient of 96.85% (2.73%). These results demonstrate that it is feasible to reconstruct slip biomimetic sensorimotor pathways that provide grasp stability for prosthetic users.
引用
收藏
页数:16
相关论文
共 41 条
  • [1] Multilevel control of an anthropomorphic prosthetic hand for grasp and slip prevention
    Barone, Roberto
    Ciancio, Anna Lisa
    Romeo, Rocco Antonio
    Davalli, Angelo
    Sacchetti, Rinaldo
    Guglielmelli, Eugenio
    Zollo, Loredana
    ADVANCES IN MECHANICAL ENGINEERING, 2016, 8 (09) : 1 - 13
  • [2] Prosthetic Hand with Biomimetic Tactile Sensing and Force Feedback
    Navaraj, William Taube
    Nassar, Habib
    Dahiya, Ravinder
    2019 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2019,
  • [3] Evaluation of Model-Based Biomimetic Control of Prosthetic Finger Force for Grasp
    Luo, Qi
    Niu, Chuanxin M.
    Liu, Jiayue
    Chou, Chih-Hong
    Hao, Manzhao
    Lan, Ning
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2021, 29 : 1723 - 1733
  • [4] A Simple Method for Slip Detection of Prosthetic Hand
    Yang, Bei
    Duan, Xiaogang
    Deng, Hua
    2015 IEEE INTERNATIONAL CONFERENCE ON INFORMATION AND AUTOMATION, 2015, : 2159 - 2164
  • [5] Stability of perception of the hand's aperture in a grasp
    Butler, Annie A.
    Heroux, Martin E.
    van Eijk, Tess
    Gandevia, Simon C.
    JOURNAL OF PHYSIOLOGY-LONDON, 2019, 597 (24): : 5973 - 5984
  • [6] A natural biomimetic prosthetic hand with neuromorphic tactile sensing for precise and compliant grasping
    Sankar, Sriramana
    Cheng, Wen-Yu
    Zhang, Jinghua
    Slepyan, Ariel
    Iskarous, Mark M.
    Greene, Rebecca J.
    Debrabander, Rene
    Chen, Junjun
    Gupta, Arnav
    Thakor, Nitish V.
    SCIENCE ADVANCES, 2025, 11 (10):
  • [7] Capacitive-Piezoelectric Tandem Architecture for Biomimetic Tactile Sensing in Prosthetic Hand
    Navaraj, William Taube
    Ozioko, Oliver
    Dahiya, Ravinder
    2018 IEEE SENSORS, 2018, : 784 - 787
  • [8] Neuromorphic compliant control facilitates human-prosthetic performance for hand grasp functions
    Xie, Anran
    Zhang, Zhuozhi
    Zhang, Jie
    Chen, Weidong
    Patton, James
    Lan, Ning
    NEUROMORPHIC COMPUTING AND ENGINEERING, 2025, 5 (01):
  • [9] Recognition of hand grasp preshaping patterns applied to prosthetic hand electromyography control
    Yang, Dapeng
    Zhao, Jingdong
    Li, Nan
    Jiang, Li
    Liu, Hong
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2012, 48 (15): : 1 - 8
  • [10] Reflex regulation of model-based biomimetic control for a tendon-driven prosthetic hand
    Luo, Qi
    Chou, Chih-Hong
    Liang, Wenyuan
    Tang, Hongbin
    Du, Ronghua
    Wei, Kexiang
    Zhang, Wenming
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2025, 101