Long-Term Mortality and Impact of Implantation-Associated Factors on the Incidence of Patient-Prosthesis Mismatch After Transcatheter Aortic Valve Implantation in Patients With Small Annuli

被引:0
作者
Voigtlaender-Buschmann, Lisa [1 ,2 ]
von der Heide, Ina [1 ]
Gossling, Alina [1 ]
Waldschmidt, Lara [1 ]
Hannen, Laura [1 ]
Grundmann, David [1 ]
Ludwig, Sebastian [1 ]
Demal, Till [2 ]
Bhadra, Oliver D. [2 ]
Schofer, Niklas [1 ]
Reichenspurner, Hermann [2 ,3 ]
Blankenberg, Stefan [1 ]
Conradi, Lenard [2 ,3 ]
Schaefer, Andreas [2 ,3 ]
Seiffert, Moritz [1 ,2 ,4 ]
机构
[1] Univ Heart & Vasc Ctr Hamburg, Dept Cardiol, Hamburg, Germany
[2] Univ Heart & Vasc Ctr Hamburg, Dept Cardiovasc Surg, Hamburg, Germany
[3] German Ctr Cardiovasc Res DZHK, Partner Site Hamburg Lubeck Kiel, Mainz, Germany
[4] Ruhr Univ Bochum, BG Univ Hosp Bergmannsheil, Dept Cardiol & Angiol, Bochum, Germany
关键词
prosthesis-patient mismatch; aortic stenosis; small aortic annuli; transcatheter aortic valve implantation; HIGH-RISK PATIENTS; CLINICAL IMPACT; REPLACEMENT; METAANALYSIS; SURVIVAL; STENOSIS;
D O I
10.1016/j.amjcard.2024.10.033
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Prosthesis-patient mismatch (PPM) is a common phenomenon after transcatheter aortic valve implantation (TAVI), especially in patients with small aortic annuli. Whether factors during implantation, such as the implantation depth, have an impact on the occurrence of PPM is currently unclear. The objectives of our study were to (1) investigate the influence of procedure planning- and implantation-related factors on the occurrence of PPM and (2) evaluate the impact of PPM on long-term mortality after TAVI. Data from 315 patients with small aortic annuli, defined as multidetector computed tomography-derived annulus area <400 mm(2), treated with transfemoral TAVI between 2014 and 2021 were retrospectively analyzed. TAVI was performed with ballon-expandable valves (BEVs) in 113 and self-expanding valves (SEVs) in 202 cases. PPM was defined according to Valve Academic Research Consortium 3 and follow-up was obtained within 5 years after TAVI. Overall, PPM occurred in 121 patients (38.4%) and was significantly more frequent in patients treated with BEVs (54.9%) than with SEVs (29.2%, p <0.001). Evaluation of planning- and implantation-related factors found that deeper implantation of BEVs significantly increased the risk of PPM (p = 0.014), whereas no association was observed in SEVs. The overall mortality rates at 3 and 5 years were 25.5% and 43.1%, respectively, without significant differences between patients with and without PPM. In conclusion, PPM occurred frequently, especially after BEV implantation. In these patients, implantation depth was identified as a predictor of PPM, whereas no association was found for SEV implantation. In addition, there was no difference in longer-term mortality between patients with and without PPM.
引用
收藏
页码:23 / 29
页数:7
相关论文
共 24 条
  • [1] Patient Prosthesis Mismatch After SAVR and TAVR
    Bleiziffer, Sabine
    Rudolph, Tanja K.
    [J]. FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [2] Aortic Stenosis and Small Aortic Annulus Clinical Challenges and Current Therapeutic Alternatives
    Freitas-Ferraz, Afonso B.
    Tirado-Conte, Gabriela
    Dagenais, Francois
    Ruel, Marc
    Al-Atassi, Talal
    Dumont, Eric
    Mohammadi, Siamak
    Bernier, Mathieu
    Pibarot, Philippe
    Rodes-Cabau, Josep
    [J]. CIRCULATION, 2019, 139 (23) : 2685 - 2702
  • [3] Généreux P, 2021, EUR HEART J, V42, P1825, DOI [10.1093/eurheartj/ehaa799, 10.1016/j.jacc.2021.02.038]
  • [4] Patient-prosthesis mismatch: surgical aortic valve replacement versus transcatheter aortic valve replacement in high risk patients with aortic stenosis
    Ghanta, Ravi K.
    Kron, Irving L.
    [J]. JOURNAL OF THORACIC DISEASE, 2016, 8 (10) : E1441 - E1443
  • [5] The impact of prosthesispatient mismatch on long-term survival after aortic valve replacement: a systematic review and meta-analysis of 34 observational studies comprising 27 186 patients with 133 141 patient-years
    Head, Stuart J.
    Mokhles, Mostafa M.
    Osnabrugge, Ruben L. J.
    Pibarot, Philippe
    Mack, Michael J.
    Takkenberg, Johanna J. M.
    Bogers, Ad J. J. C.
    Kappetein, Arie Pieter
    [J]. EUROPEAN HEART JOURNAL, 2012, 33 (12) : 1518 - 1529
  • [6] Self-Expanding or Balloon-Expandable TAVR in Patients with a Small Aortic Annulus
    Herrmann, Howard C.
    Mehran, Roxana
    Blackman, Daniel J.
    Bailey, Stephen
    Moellmann, Helge
    Abdel-Wahab, Mohamed
    Ben Ali, Walid
    Mahoney, Paul D.
    Ruge, Hendrik
    Wood, David A.
    Bleiziffer, Sabine
    Ramlawi, Basel
    Gada, Hemal
    Petronio, Anna Sonia
    Resor, Charles D.
    Merhi, William
    del Blanco, Bruno Garcia
    Attizzani, Guilherme F.
    Batchelor, Wayne B.
    Gillam, Linda D.
    Guerrero, Mayra
    Rogers, Toby
    Rovin, Joshua D.
    Szerlip, Molly
    Whisenant, Brian
    Deeb, G. Michael
    Grubb, Kendra J.
    Padang, Ratnasari
    Fan, Myra T.
    Althouse, Andrew D.
    Tchetche, Didier
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2024,
  • [7] Prosthesis-Patient Mismatch in Patients Undergoing Transcatheter Aortic Valve Replacement From the STS/ACC TVT Registry
    Herrmann, Howard C.
    Daneshvar, Samuel A.
    Fonarow, Gregg C.
    Stebbins, Amanda
    Vemulapalli, Sreekanth
    Desai, Nimesh D.
    Malenka, David J.
    Thourani, Vinod H.
    Rymer, Jennifer
    Kosinski, Andrzej S.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (22) : 2701 - 2711
  • [8] Prosthesis-patient mismatch after transcatheter implantation of contemporary balloon-expandable and self-expandable valves in small aortic annuli
    Leone, Pier Pasquale
    Regazzoli, Damiano
    Pagnesi, Matteo
    Costa, Giuliano
    Teles, Rui
    Adamo, Marianna
    Taramasso, Maurizio
    De Marco, Federico
    Mangieri, Antonio
    Kargoli, Faraj
    Ohno, Yohei
    Saia, Francesco
    Ielasi, Alfonso
    Ribichini, Flavio
    Maffeo, Diego
    Kim, Won-Keun
    Maisano, Francesco
    Van Mieghem, Nicolas M.
    Colombo, Antonio
    Reimers, Bernhard
    Latib, Azeem
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2023, 102 (05) : 931 - 943
  • [9] Meta-Analysis Comparing Risk Factors, Incidence, and Outcomes of Patients With Versus Without Prosthesis-Patient Mismatch Following Transcatheter Aortic Valve Implantation
    Lim, Oliver Zi Hern
    Mai, Aaron Shengting
    Ng, Chen Han
    Tang, Ansel
    Chin, Yip Han
    Kong, Gwyneth
    Ho, Yeung Jek
    Ong, Joy
    Tay, Edgar
    Kuntjoro, Ivandito
    Chew, Nicholas Ws
    Lim, Yinghao
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2022, 170 : 91 - 99
  • [10] Short-Term Outcome and Hemodynamic Performance of Next-Generation Self-Expanding Versus BalloonExpandable Transcatheter Aortic Valves in Patients With Small Aortic Annulus A Multicenter Propensity-Matched Comparison
    Mauri, Victor
    Kim, Won K.
    Abumayyaleh, Mohammad
    Walther, Thomas
    Moellmann, Helge
    Schaefer, Ulrich
    Conradi, Lenard
    Hengstenberg, Christian
    Hilker, Michael
    Wahlers, Thorsten
    Baldus, Stephan
    Rudolph, Volker
    Madershahian, Navid
    Rudolph, Tanja K.
    [J]. CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (10)