Intraindividual Comparison of Ultrahigh-Spatial-Resolution Photon-Counting Detector CT and Energy-Integrating Detector CT for Coronary Stenosis Measurement

被引:17
作者
Vecsey-Nagy, Milan [1 ,2 ]
Tremamunno, Giuseppe [1 ,3 ]
Schoepf, U. Joseph [1 ]
Gnasso, Chiara [1 ,4 ]
Zsarnoczay, Emese [1 ,5 ]
Fink, Nicola [1 ,6 ]
Kravchenko, Dmitrij [1 ,7 ]
Halfmann, Moritz C. [8 ]
Laux, Gerald S. [9 ]
O'Doherty, Jim [1 ,10 ]
Szilveszter, Balint [2 ]
Maurovich-Horvat, Pal [5 ]
Kabakus, Ismail Mikdat [1 ]
Suranyi, Pal Spruill [1 ]
Varga-Szemes, Akos [1 ]
Emrich, Tilman [1 ,8 ]
机构
[1] Med Univ South Carolina, Dept Radiol & Radiol Sci, Charleston, SC USA
[2] Semmelweis Univ, Heart & Vasc Ctr, Budapest, Hungary
[3] Sapienza Univ Rome, Dept Med Surg Sci & Translat Med, Radiol Unit, Rome, Italy
[4] IRCCS San Raffaele Sci Inst, Expt Imaging Ctr, Milan, Italy
[5] Semmelweis Univ, Med Imaging Ctr, Dept Radiol, MTA SE Cardiovasc Imaging Res Grp, Budapest, Hungary
[6] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Radiol, Munich, Germany
[7] Univ Hosp Bonn, Dept Diagnost & Intervent Radiol, Bonn, Germany
[8] Johannes Gutenberg Univ Mainz, Univ Med Ctr, Dept Diagnost & Intervent Radiol, Mainz, Germany
[9] Johannes Gutenberg Univ Mainz, Univ Med Ctr, Dept Cardiol, Mainz, Germany
[10] Siemens Med Solut, Malvern, PA USA
关键词
computed tomography angiography; coronary angiography; coronary artery disease; coronary stenosis; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; QUANTIFICATION; PREDICTORS;
D O I
10.1161/CIRCIMAGING.124.017112
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: A recent simulation study proposed that stenosis measurements on coronary computed tomography (CT) angiography are influenced by the improved spatial resolution of photon-counting detector (PCD)-CT. The aim of the current study was to evaluate the impact of ultrahigh-spatial-resolution (UHR) on coronary stenosis measurements and Coronary Artery Disease Reporting and Data System (CAD-RADS) reclassification rates in patients undergoing coronary CT angiography on both PCD-CT and energy-integrating detector (EID)-CT and to compare measurements against quantitative coronary angiography. METHODS: Patients with coronary calcification on EID-CT (collimation, 192x0.6 mm) were prospectively enrolled for a research coronary CT angiography with UHR PCD-CT (collimation, 120x0.2 mm) within 30 days (between April 1, 2023 and January 31, 2024). PCD-CT was acquired with the same or lower CT dose index and equivalent contrast media volume as EID-CT. Percentage diameter stenosis (PDS) for calcified, partially calcified, and noncalcified lesions were compared between scanners. Patient-level reclassification rates for CAD-RADS were evaluated. The accuracy of PDS measurements was validated against quantitative coronary angiography in patients who underwent invasive coronary angiography. RESULTS: In total, PDS of 278 plaques were quantified in 49 patients (calcified, 202; partially calcified, 51; noncalcified, 25). PCD-CT-based PDS values were lower than EID-CT measurements for calcified (45.1 +/- 20.7 versus 54.6 +/- 19.2%; P<0.001) and partially calcified plaques (44.3 +/- 19.6 versus 54.9 +/- 20.0%; P<0.001), without significant differences for noncalcified lesions (39.1 +/- 15.2 versus 39.0 +/- 16.0%; P=0.98). The reduction in stenosis degrees led to a 49.0% (24/49) reclassification rate to a lower CAD-RADS with PCD-CT. In a subset of 12 patients with 56 lesions, UHR-based PDS values showed higher agreement with quantitative coronary angiography (mean difference, 7.3%; limits of agreement, -10.7%/25.2%) than EID-CT measurements (mean difference, 17.4%; limits of agreement, -6.9%/41.7%). CONCLUSIONS: Compared with conventional EID-CT, UHR PCD-CT results in lower PDS values and more accurate stenosis measurements in coronary plaques with calcified components and leads to a substantial Coronary Artery Disease Reporting and Data System reclassification rate in 49.0% of patients.
引用
收藏
页数:9
相关论文
共 32 条
[1]   Photon-Counting Detector CT-Based Vascular Calcium Removal Algorithm Assessment Using a Cardiac Motion Phantom [J].
Allmendinger, Thomas ;
Nowak, Tristan ;
Flohr, Thomas ;
Klotz, Ernst ;
Hagenauer, Junia ;
Alkadhi, Hatem ;
Schmidt, Bernhard .
INVESTIGATIVE RADIOLOGY, 2022, 57 (06) :399-405
[2]   Diagnostic Accuracy of Computed Tomography Coronary Angiography According to Pre-Test Probability of Coronary Artery Disease and Severity of Coronary Arterial Calcification The CORE-64 (Coronary Artery Evaluation Using 64-Row Multidetector Computed Tomography Angiography) International Multicenter Study [J].
Arbab-Zadeh, Armin ;
Miller, Julie M. ;
Rochitte, Carlos E. ;
Dewey, Marc ;
Niinuma, Hiroyuki ;
Gottlieb, Ilan ;
Paul, Narinder ;
Clouse, Melvin E. ;
Shapiro, Edward P. ;
Hoe, John ;
Lardo, Albert C. ;
Bush, David E. ;
de Roos, Albert ;
Cox, Christopher ;
Brinker, Jeffrey ;
Lima, Joao A. C. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (04) :379-387
[3]   Quantification of Coronary Arterial Stenoses by Multidetector CT Angiography in Comparison With Conventional Angiography: Methods, Caveats, and Implications [J].
Arbab-Zadeh, Armin ;
Hoe, John .
JACC-CARDIOVASCULAR IMAGING, 2011, 4 (02) :191-202
[4]  
Arnett DK, 2019, CIRCULATION, V140, pE596, DOI [10.1161/CIR.0000000000000678, 10.1161/CIR.0000000000000677, 10.1016/j.jacc.2019.03.009, 10.1016/j.jacc.2019.03.010]
[5]   Contemporary Discrepancies of Stenosis Assessment by Computed Tomography and Invasive Coronary Angiography Analysis of the CORE320 International Study [J].
Bin Song, Young ;
Arbab-Zadeh, Armin ;
Matheson, Matthew B. ;
Ostovaneh, Mohammad R. ;
Vavere, Andrea L. ;
Dewey, Marc ;
Rochitte, Carlos ;
Niinuma, Hiroyuki ;
Laham, Roger ;
Schuijf, Joanne D. ;
Cox, Christopher ;
Brinker, Jeffrey ;
di Carli, Marcelo ;
Lima, Joao A. C. ;
Miller, Julie M. .
CIRCULATION-CARDIOVASCULAR IMAGING, 2019, 12 (02)
[6]   Stent imaging on a clinical dual-source photon-counting detector CT system-impact of luminal attenuation and sharp kernels on lumen visibility [J].
Decker, Josua A. A. ;
O'Doherty, Jim ;
Schoepf, U. Joseph ;
Todoran, Thomas M. M. ;
Aquino, Gilberto J. J. ;
Brandt, Verena ;
Baruah, Dhiraj ;
Fink, Nicola ;
Zsarnoczay, Emese ;
Flohr, Thomas ;
Schmidt, Bernhard ;
Allmendinger, Thomas ;
Risch, Franka ;
Varga-Szemes, Akos ;
Emrich, Tilman .
EUROPEAN RADIOLOGY, 2023, 33 (04) :2469-2477
[7]  
Eberhard M, 2024, JACC-CARDIOVASC IMAG, V17, P342, DOI 10.1016/j.jcmg.2023.10.004
[8]   Technical Basics and Clinical Benefits of Photon-Counting CT [J].
Flohr, Thomas ;
Schmidt, Bernhard .
INVESTIGATIVE RADIOLOGY, 2023, 58 (07) :441-450
[9]   Photon-counting CT review [J].
Flohr, Thomas ;
Petersilka, Martin ;
Henning, Andre ;
Ulzheimer, Stefan ;
Ferda, Jiri ;
Schmidt, Bernhard .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 79 :126-136
[10]   First in-vivo coronary stent imaging with clinical ultra high resolution photon-counting CT [J].
Geering, Ladina ;
Sartoretti, Thomas ;
Mergen, Victor ;
Cundari, Giulia ;
Rusek, Stephane ;
Civaia, Filippo ;
Rossi, Philippe ;
Wildberger, Joachim E. ;
Templin, Christian ;
Manka, Robert ;
Eberhard, Matthias ;
Alkadhi, Hatem .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2023, 17 (03) :233-235