The Use of an Artificial Intelligence-Driven Novel Tool for the Evaluation of Dental Implants Primary Stability and Immediate Loading Feasibility: A Multicenter Retrospective Study

被引:0
作者
Degidi, Marco
Daprile, Giuseppe
Battelli, Filippo
Caselli, Ernesto
Cisternino, Luca
Greco, Alessandro
Palumbo, Daniele
Quasso, Federico
Rossi, Fabio
Tavelli, Corrado
Zaccheroni, Zoran
机构
[1] Private Practice, Bologna
[2] Private Practice, Rimini
[3] Private Practice, Ancona
[4] Private Practice, Brescia
[5] Private Practice, Como
[6] Private Practice, Seregno
[7] Private Practice, Sondrio
[8] Private Practice, Imola
关键词
primary stability; artificial intelligence; dental implants; immediate loading; insertion torque;
D O I
10.3390/jcm14062011
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Objectives: A novel tool based on artificial intelligence (AIT) to evaluate immediate loading feasibility was recently introduced. The aim of this study is to evaluate the correspondence between the AIT prediction and the operator's evaluation in a large sample of implants. Methods: 11 operators were asked to classify the recorded insertion curves of all the implants placed during the period between September 2022 and August 2023 as suitable or non-suitable for immediate loading. Next, the same curves were analyzed by the AIT, which classified them as belonging to YES (suitable for immediate loading) or NO (non-suitable for immediate loading) class. Results: 1320 dental implants were placed and a total of 21 different implant systems were used. According to the surgeons' evaluation, 999 curves were suitable and 321 were non-suitable for immediate loading; when evaluated by the AIT, 916 curves belonged to class YES, while 404 belonged to class NO. The resulted sensitivity was 90.49% (95% CI = 88.5% to 92.2), specificity was 96.26% (95% CI = 93.6% to 98.1%), PPV was 98.7% (95% CI = 97.7% to 99.3%), and NPV was 76.5% (95% CI = 72% to 80.5%). Conclusions: The AIT tested in the present clinical multicenter study demonstrated a high level of accuracy in the prediction of immediate loading feasibility.
引用
收藏
页数:9
相关论文
共 16 条
  • [1] Atsumi M, 2007, INT J ORAL MAX IMPL, V22, P743
  • [2] Accuracy of Artificial Intelligence-Based Photographic Detection of Gingivitis
    Chau, Reinhard Chun Wang
    Li, Guan-Hua
    Tew, In Meei
    Thu, Khaing Myat
    McGrath, Colman
    Lo, Wai-Lun
    Ling, Wing-Kuen
    Hsung, Richard Tai-Chiu
    Lam, Walter Yu Hang
    [J]. INTERNATIONAL DENTAL JOURNAL, 2023, 73 (05) : 724 - 730
  • [3] Automated Identification of Dental Implants Using Artificial Intelligence
    da Mata Santos, Rafael Pereira
    Vieira Oliveira Prado, Higor Eduardo
    Aranha Neto, Idalisio Soares
    Alves de Oliveira, Guilherme Augusto
    Vespasiano Silva, Amaro Ilidio
    Zenobio, Elton Goncalves
    Manzi, Flavio Ricardo
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2021, 36 (05) : 918 - 923
  • [4] Artificial Intelligence: A New Diagnostic Software in Dentistry: A Preliminary Performance Diagnostic Study
    De Angelis, Francesca
    Pranno, Nicola
    Franchina, Alessio
    Di Carlo, Stefano
    Brauner, Edoardo
    Ferri, Agnese
    Pellegrino, Gerardo
    Grecchi, Emma
    Goker, Funda
    Stefanelli, Luigi Vito
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (03)
  • [5] Use of a Novel Artificial Intelligence Tool for Evaluating Primary Stability and Immediate Loading Suitability of Dental Implants: An In Vitro Pilot Study
    Degidi, Marco
    Daprile, Giuseppe
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2024, 39 (04) : e129 - e135
  • [6] Development of a New Implant Primary Stability Parameter: Insertion Torque Revisited
    Degidi, Marco
    Daprile, Giuseppe
    Piattelli, Adriano
    Iezzi, Giovanna
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2013, 15 (05) : 637 - 644
  • [7] Degidi M, 2010, INT J ORAL MAX IMPL, V25, P558
  • [8] Meredith N, 1998, INT J PROSTHODONT, V11, P491
  • [10] Clinical study on the primary stability of two dental implant systems with resonance frequency analysis
    Rabel, Annette
    Koehler, Steffen Gerhard
    Schmidt-Westhausen, Andrea Maria
    [J]. CLINICAL ORAL INVESTIGATIONS, 2007, 11 (03) : 257 - 265