Intraocular Pressure Fluctuation as Assessed by Water Drinking Test following iStent Inject Implantation in Open-Angle Glaucoma Patients

被引:0
|
作者
Khoo, Phong Yue [1 ,2 ]
Lam, Chenshen [1 ,2 ]
Tang, Seng Fai [1 ,2 ,3 ]
Perera, Shamira [4 ]
Cheng, Teck Chee [1 ,2 ]
Din, Norshamsiah Md [1 ,2 ]
机构
[1] Univ Kebangsaan Malaysia, Med Ctr, Fac Med, Dept Ophthalmol, Kuala Lumpur, Malaysia
[2] Hosp Canselor Tuanku Muhriz, Kuala Lumpur, Malaysia
[3] Optimax Eye Specialist Ctr, Kuala Lumpur, Malaysia
[4] Singapore Natl Eye Ctr, Singapore, Singapore
关键词
Intraocular pressure fluctuation; iStent; Open-angle glaucoma; VISUAL-FIELD PROGRESSION; MICROBYPASS STENT IMPLANTATION; MICRO-BYPASS STENTS; CATARACT-SURGERY; RISK-FACTOR; PHACOEMULSIFICATION; SAFETY; PEAK;
D O I
10.1159/000542081
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Introduction:This study investigated the intraocular pres-sure (IOP)fluctuation as assessed by the water drinking test(WDT) in open-angle glaucoma (OAG) patients after com-bined cataract surgery with iStent implantation.Methods:This was a prospective non-randomized comparative study.Eyes with OAG and cataracts that were planned for eithercombined phacoemulsification and iStent implantation(iStent+CS) or phacoemulsification alone (CS) were re-cruited. The iStent inject (Model G2-M-IS) or iStent injectW(Model G2-W) trabecular micro-bypass stent (GlaukosCorporation, San Clemente, CA, USA) was implanted in theiStent+CS group. WDT was performed before and 3 monthsafter surgery. WDT-IOP parameters including peak IOP, IOPfluctuation, and area under the curve (AUC) were comparedbetween the two groups.Results:Therewere20eyesintheiStent+CS group and 16 eyes in the CS group. Both groupshad similar pre-operative baseline IOP (15.6 +/- 3.7 mm Hg vs.15.8 +/- 1.8 mm Hg in the iStent+CS and CS group, re-spectively,p= 0.883). The iStent+CS group experiencedgreater numerical reduction in peak IOP (2.6 +/- 1.9 mm Hgvs. 1.9 +/- 2.4 mm Hg;p= 0.355), IOPfluctuation (1.7 +/- 2.2 mmHg vs. 0.8 +/- 2.5 mm Hg;p= 0.289), and AUC (54.8 +/- 103.6 mm Hg x minute vs. 25.3 +/- 79.0 mm Hg x minute;p=0.355) than the CS group. There was more reduction in thenumber of anti-glaucoma medications in the iStent+CSgroup (1.4 +/- 1.2) than the CS group (0.3 +/- 0.9;p=0.005).Conclusion:Both combined phacoemulsification with iS-tent inject implantation and phacoemulsification alonereduced peak IOP, IOPfluctuation, and AUC, and none ofthese parameters showed statistically significant difference.Greater reduction in anti-glaucoma medications was seen inthe combined group.(c) 2024 The Author(s).Published by S. Karger AG, Basel
引用
收藏
页码:635 / 643
页数:9
相关论文
共 50 条
  • [21] Treatment of Open-Angle Glaucoma with iStent Implantation Combined with Phacoemulsification in Polish Caucasian Population
    Kozera, Milena
    Konopinska, Joanna
    Mariak, Zofia
    Rekas, Marek
    CLINICAL OPHTHALMOLOGY, 2021, 15 : 473 - 480
  • [22] Combined iStent® Inject Trabecular Micro-Bypass and Phacoemulsification in Australian Patients with Open-Angle Glaucoma
    Salby, Alon M.
    Skalicky, Simon E.
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 985 - 993
  • [23] Rise of intraocular pressure in a caffeine test versus the water drinking test in patients with glaucoma
    Tuan Tran
    Niyadurupola, Nuwan
    O'Connor, Jeremy
    Ang, Ghee Soon
    Crowston, Jonathan
    Dan Nguyen
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 42 (05) : 427 - 432
  • [24] iStent Trabecular Microbypass Stent Implantation with Phacoemulsification in Patients with Open-Angle Glaucoma: 6-Year Outcomes
    Ferguson, Tanner J.
    Mechels, Keegan B.
    Dockter, Zachary
    Bleeker, Adam
    Ibach, Mitch
    Schweitzer, Justin
    Berdahl, John P.
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 1859 - 1866
  • [25] Seasonal Fluctuation in Intraocular Pressure and Retinal Nerve Fiber Layer Thinning in Primary Open-Angle Glaucoma
    Terauchi, Ryo
    Ogawa, Shumpei
    Noro, Takahiko
    Ito, Kyoko
    Kato, Tomohiro
    Tatemichi, Masayuki
    Nakano, Tadashi
    OPHTHALMOLOGY GLAUCOMA, 2021, 4 (04): : 373 - 381
  • [26] A Comparative Study of the Water Drinking Test in Eyes With Open-Angle Glaucoma and Prior Trabeculectomy or Tube Shunt
    Martinez, Patricia
    Trubnik, Valerie
    Leiby, Benjamin E.
    Hegarty, Sarah E.
    Razeghinejad, Reza
    Savant, Shravan
    Myers, Jonathan S.
    JOURNAL OF GLAUCOMA, 2017, 26 (02) : 119 - 125
  • [27] Intraocular pressure after phacoemulsification with posterior chamber lens implantation in open-angle glaucoma
    Hudovernik, M
    Pahor, D
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2003, 220 (12) : 835 - 839
  • [28] Dampening of Diurnal Intraocular Pressure Fluctuation by Combined Trabeculotomy and Sinusotomy in Eyes With Open-angle Glaucoma
    Matsuoka, Masato
    Ando, Akira
    Minamino, Keizo
    Matsuyama, Kayako
    Shima, Chieko
    Matsumura, Miyo
    Nishimura, Tetsuya
    JOURNAL OF GLAUCOMA, 2013, 22 (04) : 290 - 293
  • [29] Efficacy and Safety of Pairing iStent Inject Trabecular Micro-Bypass and iAccess Precision Blade Goniotomy in Patients with Open-Angle Glaucoma
    Gallardo, Mark J.
    Porter, Matthew
    OPHTHALMOLOGY AND THERAPY, 2023, 12 (04) : 1973 - 1987
  • [30] Kahook Dual Blade Goniotomy vs iStent inject: Long-Term Results in Patients with Open-Angle Glaucoma
    Arnljots, Thorsteinn S.
    Economou, Mario A.
    CLINICAL OPHTHALMOLOGY, 2021, 15 : 541 - 550