Vector based fault isolation in closed-loop systems

被引:0
|
作者
Niemann, Henrik [1 ]
Poulsen, Niels Kjolstad [2 ]
机构
[1] Tech Univ Denmark, Dept Elect & Photon Engn, DK-2800 Lyngby, Denmark
[2] Tech Univ Denmark, Dept Appl Math & Comp Sci, DK-2800 Lyngby, Denmark
来源
IFAC PAPERSONLINE | 2024年 / 58卷 / 04期
关键词
Active fault isolation; residual generators; parametric faults; closed-loop systems; DESIGN;
D O I
10.1016/j.ifacol.2024.07.295
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Isolation of parametric faults in closed-loop MIMO systems is considered in this paper. A double residual generator is applied for the isolation. First, it is shown that there is a linear dependency of the single parametric faults and the residual vector. Based on this linear dependency together with the dual residual vector, residual output directions are calculated for each parametric fault. These output directions for the residuals are independent of the value of the single faults. The fault isolation is then done by comparing the residual vector with the calculated output vectors for the different faults. To isolate a fault, the calculated output vector for the given fault and the residual vector need to be parallel. The scalar vector product between the vectors is applied as a simple test method for fault isolation. Copyright (c) 2024 The Authors.
引用
收藏
页码:664 / 669
页数:6
相关论文
共 50 条
  • [1] Fault detection and isolation for uncertain closed-loop systems based on adaptive and switching approaches
    Li, Xiao-Jian
    Yang, Guang-Hong
    INTERNATIONAL JOURNAL OF ROBUST AND NONLINEAR CONTROL, 2016, 26 (13) : 2916 - 2937
  • [2] Fault diagnosis based on parameter estimation in closed-loop systems
    Zhai, Shouchao
    Wang, Wei
    Ye, Hao
    IET CONTROL THEORY AND APPLICATIONS, 2015, 9 (07): : 1146 - 1153
  • [3] Optimal sensor location in closed-loop control systems for fault detection and isolation
    Xu, YH
    Jin, J
    PROCEEDINGS OF THE 2000 AMERICAN CONTROL CONFERENCE, VOLS 1-6, 2000, : 1195 - 1199
  • [4] Estimation of Parametric Fault in Closed-loop Systems
    Niemann, Henrik
    Poulsen, Niels Kjolstad
    2015 AMERICAN CONTROL CONFERENCE (ACC), 2015, : 201 - 206
  • [5] Adaptive Fault Detection and Isolation Approach for Actuator Stuck Faults in Closed-Loop Systems
    Li, Xiao-Jian
    Yang, Guang-Hong
    INTERNATIONAL JOURNAL OF CONTROL AUTOMATION AND SYSTEMS, 2012, 10 (04) : 830 - 834
  • [6] Adaptive fault detection and isolation approach for actuator stuck faults in closed-loop systems
    Xiao-Jian Li
    Guang-Hong Yang
    International Journal of Control, Automation and Systems, 2012, 10 : 830 - 834
  • [7] Review on fault diagnosis techniques for closed-loop systems
    Zhou, Dong-Hua
    Liu, Yang
    He, Xiao
    Zidonghua Xuebao/Acta Automatica Sinica, 2013, 39 (11): : 1933 - 1943
  • [8] Active fault diagnosis in closed-loop uncertain systems
    Ørsted DTU, Automation, Technical University of Denmark, DK-2800 Kgs. Lyngby, Denmark
    IFAC Proc. Vol. (IFAC-PapersOnline), PART 1 (587-592):
  • [9] Fault Detection for Closed-Loop Control Systems Based on Parity Space Transformation
    Sun, Bowen
    Wang, Jiongqi
    He, Zhangming
    Qin, Yongrui
    Wang, Dayi
    Zhou, Haiyin
    IEEE ACCESS, 2019, 7 : 75153 - 75165
  • [10] Adaptive Kalman filtering for closed-loop systems based on the observation vector covariance
    Limaverde Filho, J. O. A.
    Fortaleza, E. L. F.
    Silva, J. G.
    de Campos, M. C. M. M.
    INTERNATIONAL JOURNAL OF CONTROL, 2022, 95 (07) : 1731 - 1746